![Peri 117465 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/peri/117465/117465_translation-of-the-original-instructions-for-use_1529942031.webp)
29
Application
Hydraulic Head Spindle Device VST
Translation of the Original Instructions for Use
Height adjustment
1.3
Warning
– Before using the Hydraulic Head
Spindle Device VST, check that all
components are properly connected
to each other!
– Remove or secure any loose compo-
nents!
– Do not exceed the max. operating
pressure 680 bar (700 kN)!
– Do not exceed the maximum spin-
dling height!
– When working on existing struc-
tures, permanently monitor the situ-
ation, e.g. cracks, falling building
parts, or noises.
– If the specified height has been
reached, secure with the spindle
(1.3) nut in order to relieve the load
on the cylinder! (Fig. 18)
– During operations, keep hands and
feet away from the cylinder and
Head Spindle VST 100 in order to
prevent injuries!
– Raise Hydraulic Head Spindle Device
VST under load in max. 10 mm
increments!
– Project-specific statics, a pre-ten-
sioning or lowering plan is required!
Operating pressure conversion in kN
1 bar
= 1.026 kN
1 psi
= 7.074 kN
Fig. 18