background image

 

PRODUCT SPECIFICATIONS

Blue (Low) Gauge 

0-120psi

Blue Hose 

 

¼ in. FFL x 50 in.

Red (High) Gauge 

0-500psi

Red Hose 

 

¼ in. FFL x 50 in.

Yellow Hose 

 

½ in. ACME x 50 in.

Gauge Accuracy 

+/-2%

1. Keep work area clean and well lit. 

2. Keep children away. Children must never be allowed 

in the work area. Do not let them handle the A/C Mani-

fold Gauge Set. 

3. There are certain applications for which this A/C 

Manifold Gauge Set was designed. It will do the job bet-

ter and more safely at the rate for which it was intended. 

Do not modify this A/C Manifold Gauge Set and do not 

use this A/C Manifold Gauge Set for a purpose for which 

it was not intended. 

4. Dress properly. Do not wear loose clothing or jewelry 

as they can be caught in moving engine parts. Protec-

tive clothes and nonskid footwear are recommended 

when working. Wear restrictive hair covering to contain 

long hair. 

5. Wear ANSI-approved impact safety goggles and 

heavy-duty work gloves at all times during setup and use. 

6. Do not overreach. Keep proper footing and balance at 

all times. 

7. Maintain gauge with care. Keep the A/C Manifold 

Gauge Set clean for better and safer performance. 

Inspect hoses periodically, and if damaged, have them 

repaired by a qualified technician.

8. Stay alert. Watch what you are doing, use common 

sense. Do not operate gauge when you are tired. 

9. Check for damaged parts. Before using any gauge, 

any part that appears damaged should be carefully 

checked to determine that it will operate properly and 

perform its intended function. Check for alignment and 

binding of moving parts; any broken parts or mounting 

fixtures; and any other condition that may affect proper 

operation. Any part that is damaged should be properly 

repaired or replaced by a qualified technician. 

10. Replacement parts and accessories. When servic-

ing, use only identical replacement parts. Use of any 

other parts will void the warranty. Only use accessories 

intended for use with this gauge.  

11. Do not operate gauge if under the influence of alco-

hol or drugs. Read warning labels if taking prescription 

medicine to determine if your judgment or reflexes are 

impaired while taking drugs. If there is any doubt, do not 

operate the gauge. 

12. Maintenance. For your safety, service and maintenance 

should be performed regularly by a qualified technician. 

13. Industrial applications must follow OSHA requirements.

14. People with pacemakers should consult their 

physician(s) before using this product. Electromagnetic 

fields in close proximity to a heart pacemaker could 

cause interference to or failure of the pacemaker. In 

addition, people with pacemakers should observe the 

following: Caution is necessary when near the coil, spark 

plug cables, or distributor of a running engine.

16. The warnings, cautions, and instructions discussed 

in this instruction manual cannot cover all possible condi-

tions and situations that may occur. It must be under-

stood by the operator that common sense and caution 

are factors, which cannot be built into this product, but 

must be supplied by the operator.

17. ONLY USE REFRIGERANT R-134a WITH THIS A/C 

MANIFOLD GAUGE SET.

18. Do not start an engine in an enclosed area (like a 

garage). A running gasoline engine generates carbon 

monoxide; carbon monoxide is a colorless, odorless gas 

that can cause serious injury and death, if inhaled.

19. Keep hands away from the moving parts and hot 

parts of vehicle’s engine.

20. Read and understand all instructions and safety 

precautions as outlined in the vehicle manufacturer’s 

manual for air condition servicing. Only qualified me-

chanics that are trained in servicing air conditioning 

systems should use this product.

21. When warming up an engine in preparation for 

checking of the A/C system, make sure the vehicle’s 

transmission is placed in “Park” and the emergency 

brake is applied.

22. Refrigerant can cause severe frostbite if it comes in 

contact with skin.Follow the safety warnings and instruc-

tions provided by the refrigerant manufacturer.

23. Do not disconnect any pressurized hose. Pressur-

ized refrigerant can cause severe injury.

24. Use caution when opening an air conditioning sys-

tem line or can of refrigerant. When checking, always 

place a towel around the service valves of the air condi-

tioning unit and Red and Blue Couplers (22 and 23).

25. Keep refrigerant away from excessive heat as pressure 

in the container could increase enough to rupture the can.

26. Do not discharge refrigerant into the atmosphere. 

Capture refrigerant into an approved recovery container 

(not included), and then dispose of properly. Contact your 

local Hazardous Waste Authority for disposal guidelines. 

27. Only use refrigerant in a manner consistent with the 

air conditioning system’s repair manual.

SAVE THESE

INSTRUCTIONS

Содержание W89730

Страница 1: ...kes no express or implied warranties of any kind with respect to its products In particular PERFORMANCE TOOL makes no implied warranty of merchantability and no implied warranty of fitness for any particular purpose except that for goods purchased primarily for personal family or household use and not for commercial or business use PERFORMANCE TOOL makes an implied warranty of merchantability and i...

Страница 2: ...by a qualified technician 13 Industrial applications must follow OSHA requirements 14 People with pacemakers should consult their physician s before using this product Electromagnetic fields in close proximity to a heart pacemaker could cause interference to or failure of the pacemaker In addition people with pacemakers should observe the following Caution is necessary when near the coil spark plu...

Страница 3: ...em c For checking attach the Yellow Hose 18 to both branches of the T fitting 16 to reduce the risk of leaks 7 The charge valve allows for simultaneous connection of a refrigerant recovery system 8 General instructions for A C service are outlined in this manual Specific procedures for each individual system type and model should be referenced in the vehicle manufacturer s specific A C system serv...

Страница 4: ...air if allowed to accumulate causing sudden loss of con sciousness followed by death This can happen WITHOUT FEELING SHORTNESS OF BREATH TO PREVENT EXPLOSION SERIOUS INJURY AND DEATH Do not open the red HP Manifold Valve unless requested to do so during the recovery evacuation proce dure Refrigerant is under great pressure Attempting to add refrigerant through the HP side of the system may cause t...

Страница 5: ...ed Hose 17 to the Red LP Hose Connector and the other end to the Red Coupler 22 c Connect one end of the Yellow Hose 18 to the Yellow Charge Hose Connec tor 16 and the other end to the Charge Valve on that Connector 3 ATTACH COUPLERS a Attach the Blue Coupler 22 to the suction LP port on the A C system b Attach the Red Coupler 23 to the discharge HP port on the A C system 4 PERFORM CHECK a To do a...

Страница 6: ...other end to the Red Coupler 22 c Connect one end of the Yellow Hose 18 to the Yellow Charge Hose Connector 16 and the other end to the refrigerant recovery system vacuum pump 3 ATTACH COUPLERS a Attach the Blue Coupler 22 to the suction LP port on the A C system b Attach the Red Coupler 23 to the discharge HP port on the A C system 4 PERFORM RECOVERY EVACUATION a Turn on the refrigerant recovery ...

Страница 7: ...tor and the other end to the Red Coupler 22 c Connect one end of the Yellow Hose 18 to the Yellow Charge Hose Connector 16 and the other end to refrigerant supply KEEP THE CAN CYLINDER UPRIGHT 3 ATTACH COUPLERS a Attach the Blue Coupler 23 to the suction LP port on the A C system b Attach the Red Coupler 23 to the dis charge HP port on the A C system 4 PERFORM CHARGING a Turn on the vehicle and al...

Страница 8: ...lug 1 8 Valve Seat 2 9 Valve Stem 2 10 Valve Nut 2 11 Manifold Valve 2 12 O Ring 1 Part Description Qty 13 Sight Glass 1 14 Ring Nut 1 15 Connector 2 16 T Connector 1 17 Red Hose HP Refrigerant 1 18 Yellow Hose HP Refrigerant 1 19 Blue Hose LP Refrigerant 1 20 Connector 2 21 O Ring 2 22 Red Coupler HP 1 23 Blue Coupler LP 1 PARTS LIST AND ASSEMBLY DIAGRAM HP means High Pressure LP means Low Pressu...

Отзывы: