background image

WARNING

TO PREVENT SERIOUS INJURY FROM TOOL FAIL-

URE: Do not use damaged equipment. If abnormal 

noise, vibration, or leaking air occurs, have the prob-

lem corrected before further use.

1.  

Before each use, inspect the general condition of 

 

the A/C Manifold Set. Check for cracked or 

 

broken parts, damaged Hoses (17,18,19), and 

 

any other condition that may affect safe operation. 

 

If a problem with the Set occurs, have it corrected 

 

before further use. 

 

Do not use damaged equipment.

2.  

Periodically, clean with a damp cloth using a mild 

 

detergent or solvent.

3.  

When storing, keep the set clean and dry. Also, 

 

connect the Red Coupler (22) and the Blue 

 

Coupler (23) to its corresponding Coupler Storage 

 

Plug (7 or 6 respectively) to prevent contamination.

 

INSPECTION, MAINTENANCE AND CLEANING

Part 

Description 

   Qty.

Rubber Cover   

 

 

   1

Manifold Body   

 

 

   1

Red HP Gauge   

 

 

   1

4 Hook 

     

 

 

1

Blue LP Gauge   

 

 

   1

Blue Coupler Storage Plug 

 

   1

Red Coupler Storage Plug 

 

   1

Valve Seat 

 

 

 

   2

Valve Stem 

 

 

 

   2

10 

Valve Nut 

 

 

 

   2

11 

Manifold Valve   

 

 

   2

12 

O-Ring 

     

 

 

1

Part 

Description 

   Qty.

13 

Sight Glass 

 

 

 

   1

14 

Ring Nut 

 

 

 

   1

15 

Connector 

 

 

 

   2

16 

T Connector   

 

 

   1

17 

Red Hose (HP Refrigerant) 

 

   1

18 

Yellow Hose (HP Refrigerant)   

   1

19 

Blue Hose (LP Refrigerant) 

 

   1

20 

Connector 

 

 

 

   2

21 

O-Ring 

     

 

 

2

22 

Red Coupler (HP) 

 

 

   1

23 

Blue Coupler (LP) 

 

 

   1

 

PARTS LIST AND ASSEMBLY DIAGRAM       

HP means High-Pressure       LP means Low-Pressure

PLEASE READ THE FOLLOWING CAREFULLY

THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED 

THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS 

A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR 

DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY 

OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO 

REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE 

MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY STATES 

THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD 

BE UNDERTAKEN BY CERTIFIED AND LICENSED 

TECHNICIANS, AND NOT BY THE BUYER. THE 

BUYER ASSUMES ALL RISKS AND LIABILITY 

ARISING OUT OF HIS OR HER REPAIRS TO 

THE ORIGINAL PRODUCT OR REPLACEMENT 

PARTS THERETO, OR ARISING OUT OF HIS 

OR HER INSTALLATION OF REPLACEMENT 

PARTS THERETO.

Содержание W89730

Страница 1: ...kes no express or implied warranties of any kind with respect to its products In particular PERFORMANCE TOOL makes no implied warranty of merchantability and no implied warranty of fitness for any particular purpose except that for goods purchased primarily for personal family or household use and not for commercial or business use PERFORMANCE TOOL makes an implied warranty of merchantability and i...

Страница 2: ...by a qualified technician 13 Industrial applications must follow OSHA requirements 14 People with pacemakers should consult their physician s before using this product Electromagnetic fields in close proximity to a heart pacemaker could cause interference to or failure of the pacemaker In addition people with pacemakers should observe the following Caution is necessary when near the coil spark plu...

Страница 3: ...em c For checking attach the Yellow Hose 18 to both branches of the T fitting 16 to reduce the risk of leaks 7 The charge valve allows for simultaneous connection of a refrigerant recovery system 8 General instructions for A C service are outlined in this manual Specific procedures for each individual system type and model should be referenced in the vehicle manufacturer s specific A C system serv...

Страница 4: ...air if allowed to accumulate causing sudden loss of con sciousness followed by death This can happen WITHOUT FEELING SHORTNESS OF BREATH TO PREVENT EXPLOSION SERIOUS INJURY AND DEATH Do not open the red HP Manifold Valve unless requested to do so during the recovery evacuation proce dure Refrigerant is under great pressure Attempting to add refrigerant through the HP side of the system may cause t...

Страница 5: ...ed Hose 17 to the Red LP Hose Connector and the other end to the Red Coupler 22 c Connect one end of the Yellow Hose 18 to the Yellow Charge Hose Connec tor 16 and the other end to the Charge Valve on that Connector 3 ATTACH COUPLERS a Attach the Blue Coupler 22 to the suction LP port on the A C system b Attach the Red Coupler 23 to the discharge HP port on the A C system 4 PERFORM CHECK a To do a...

Страница 6: ...other end to the Red Coupler 22 c Connect one end of the Yellow Hose 18 to the Yellow Charge Hose Connector 16 and the other end to the refrigerant recovery system vacuum pump 3 ATTACH COUPLERS a Attach the Blue Coupler 22 to the suction LP port on the A C system b Attach the Red Coupler 23 to the discharge HP port on the A C system 4 PERFORM RECOVERY EVACUATION a Turn on the refrigerant recovery ...

Страница 7: ...tor and the other end to the Red Coupler 22 c Connect one end of the Yellow Hose 18 to the Yellow Charge Hose Connector 16 and the other end to refrigerant supply KEEP THE CAN CYLINDER UPRIGHT 3 ATTACH COUPLERS a Attach the Blue Coupler 23 to the suction LP port on the A C system b Attach the Red Coupler 23 to the dis charge HP port on the A C system 4 PERFORM CHARGING a Turn on the vehicle and al...

Страница 8: ...lug 1 8 Valve Seat 2 9 Valve Stem 2 10 Valve Nut 2 11 Manifold Valve 2 12 O Ring 1 Part Description Qty 13 Sight Glass 1 14 Ring Nut 1 15 Connector 2 16 T Connector 1 17 Red Hose HP Refrigerant 1 18 Yellow Hose HP Refrigerant 1 19 Blue Hose LP Refrigerant 1 20 Connector 2 21 O Ring 2 22 Red Coupler HP 1 23 Blue Coupler LP 1 PARTS LIST AND ASSEMBLY DIAGRAM HP means High Pressure LP means Low Pressu...

Отзывы: