 APPLICATIONS

1. The Red HP Gauge (3) is used to measure high pressure compressor discharge side pressure.

2. The Blue LP Gauge (5) is used to measure low-pressure side suction or pressure.

3. The Manifold Valves (11) control the flow of refrigerant to and from the Yellow Hose (18), also called the Charge Hose.

4. The Coupler Valves (22,23) control the flow to the Gauges (3, 5) from the Red and Blue Hoses (17,19).

5. The Sight Glass (13) allows checking the appearance of the refrigerant.

6. The Yellow Hose (18), also called Charge Hose can be used three ways:

 

a. Refrigerant recovery/evacuation.

 

b. Charging (filling) the system.

 

c. For checking, attach the Yellow Hose (18) to both branches of the T-fitting (16) to reduce the risk of leaks.

7. The charge valve allows for simultaneous connection of a refrigerant recovery system.

8. General instructions for A/C service are outlined in this manual. Specific procedures for each individual system type 

 

and model should be referenced in the vehicle manufacturer’s specific A/C system service manual.

9. See Operation instructions that follow.

 

COMPONENTS AND FUNCTIONS

 LOW-PRESSURE 

    HIGH-PRESSURE 

 

 (LP) BLUE SIDE   

 

 

 

  (HP) RED SIDE

Charge 

Valve

Blue 

Coupler 

Storage 

Plug (6)

Blue 

Coupler 

(23)

Red 

Coupler 

(22)

Red 

Coupler 

Storage 

Plug (7)

Red HP 

Gauge (3)

Blue LP 

Gauge (5)

Red HP 

Manifold 

Valve

Blue LP 

Manifold 

Valve

Yellow Charge Hose 

Connector (16)

Red HP Hose 

Connector

Blue LP Hose 

Connector

Sight 

Glass 

(13)

Содержание W89730

Страница 1: ...kes no express or implied warranties of any kind with respect to its products In particular PERFORMANCE TOOL makes no implied warranty of merchantability and no implied warranty of fitness for any particular purpose except that for goods purchased primarily for personal family or household use and not for commercial or business use PERFORMANCE TOOL makes an implied warranty of merchantability and i...

Страница 2: ...by a qualified technician 13 Industrial applications must follow OSHA requirements 14 People with pacemakers should consult their physician s before using this product Electromagnetic fields in close proximity to a heart pacemaker could cause interference to or failure of the pacemaker In addition people with pacemakers should observe the following Caution is necessary when near the coil spark plu...

Страница 3: ...em c For checking attach the Yellow Hose 18 to both branches of the T fitting 16 to reduce the risk of leaks 7 The charge valve allows for simultaneous connection of a refrigerant recovery system 8 General instructions for A C service are outlined in this manual Specific procedures for each individual system type and model should be referenced in the vehicle manufacturer s specific A C system serv...

Страница 4: ...air if allowed to accumulate causing sudden loss of con sciousness followed by death This can happen WITHOUT FEELING SHORTNESS OF BREATH TO PREVENT EXPLOSION SERIOUS INJURY AND DEATH Do not open the red HP Manifold Valve unless requested to do so during the recovery evacuation proce dure Refrigerant is under great pressure Attempting to add refrigerant through the HP side of the system may cause t...

Страница 5: ...ed Hose 17 to the Red LP Hose Connector and the other end to the Red Coupler 22 c Connect one end of the Yellow Hose 18 to the Yellow Charge Hose Connec tor 16 and the other end to the Charge Valve on that Connector 3 ATTACH COUPLERS a Attach the Blue Coupler 22 to the suction LP port on the A C system b Attach the Red Coupler 23 to the discharge HP port on the A C system 4 PERFORM CHECK a To do a...

Страница 6: ...other end to the Red Coupler 22 c Connect one end of the Yellow Hose 18 to the Yellow Charge Hose Connector 16 and the other end to the refrigerant recovery system vacuum pump 3 ATTACH COUPLERS a Attach the Blue Coupler 22 to the suction LP port on the A C system b Attach the Red Coupler 23 to the discharge HP port on the A C system 4 PERFORM RECOVERY EVACUATION a Turn on the refrigerant recovery ...

Страница 7: ...tor and the other end to the Red Coupler 22 c Connect one end of the Yellow Hose 18 to the Yellow Charge Hose Connector 16 and the other end to refrigerant supply KEEP THE CAN CYLINDER UPRIGHT 3 ATTACH COUPLERS a Attach the Blue Coupler 23 to the suction LP port on the A C system b Attach the Red Coupler 23 to the dis charge HP port on the A C system 4 PERFORM CHARGING a Turn on the vehicle and al...

Страница 8: ...lug 1 8 Valve Seat 2 9 Valve Stem 2 10 Valve Nut 2 11 Manifold Valve 2 12 O Ring 1 Part Description Qty 13 Sight Glass 1 14 Ring Nut 1 15 Connector 2 16 T Connector 1 17 Red Hose HP Refrigerant 1 18 Yellow Hose HP Refrigerant 1 19 Blue Hose LP Refrigerant 1 20 Connector 2 21 O Ring 2 22 Red Coupler HP 1 23 Blue Coupler LP 1 PARTS LIST AND ASSEMBLY DIAGRAM HP means High Pressure LP means Low Pressu...

Отзывы: