WMD-06 Motorized electromechanical swing gate
Dear customer!
Thank you for purchasing the PERCo product.
Please follow instructions given in this Manual carefully,
and this quality product will provide many years of trouble-free use.
The Assembly and Operation Manual
(hereinafter – the Manual) contains the instructions the
user will need for safe transportation, storage, installation, operation and maintenance of the
WMD-06
motorized electromechanical swing gate.
The product installation must be carried out by qualified installers in strict accordance with the
Manual.
Abbreviations adopted in the Manual:
ACS – access control system;
RC – remote control;
WRC – wireless remote control.
1
APPLICATION
The
WMD-06
motorized electromechanical swing gate
(hereinafter – the
swing gate
) is
designed for managing pedestrian flows at entrance points of industrial facilities, banks,
administrative buildings, retail outlets, railway terminals, airports, etc. Being an up-market model, it
is recommended to meet the highest requirements for design and comfort. It can be installed
together with other turnstiles and railings produced by
PERCo
or it can be used as a separate
device.
It is recommended to define the number of swing gates necessary to secure fast and convenient
passage in accordance with throughput rate (see Section 3). For example, it is recommended to
install one turnstile per 500 people on the basis of maximum working load of 12 persons/min.
2
OPERATING CONDITIONS
The swing gate, with regard to resistance to environmental exposure, complies with
GOST 15150-69, category U4 (operation in premises with climate control).
Operation of the swing gate is allowed at ambient air temperature from +1°
С
to +50°
С
and at
relative air humidity of up to 70% at +27°
С
.
3
TECHNICAL SPECIFICATIONS
Operating voltage
....................................................................................................... 24
V DC ±10%
Current consumption
.........................................................................................................
max. 4.4
А
Power consumption ........................................................................................................ max.105
W
Throughput rate in single passage mode................................................................... 12
persons/min
Operating modes ............................................................................................................................. 3
Passageway width with
AGG-650
swing panel .................................................................... 700
mm
Passageway width with
AGG-900
swing panel .................................................................... 950
mm
Length of RC cable
.......................................................................................................... min. 6.6
m
IP Code .................................................................................................................... IP41 (EN 60529)
Electric shock protection class .................................................................................... III (IEC 61140)
Mean time to failure ..................................................................................... min. 500 000
passages
Mean lifetime .................................................................................................................. min. 8
years
Overall dimensions with
AGG-650
swing panel ................................................. 795×147×1012
mm
Overall dimensions with
AGG-900
swing panel ............................................... 1045×147×1012
mm
Net weight with
AGG-650
swing panel ............................................................................ max. 37
kg
Net weight with
AGG-900
swing panel ............................................................................ max. 41
kg
1
Maximum length of RC cable is 30 m (upon request).