Assembly and Operation Manual 

The duration of waiting period for “

Direction open

” mode is defined by the duration of control signal 

on the contact related to opening direction of the swing panel. 

9.4  Emergency situations 

In case of fire, disasters and any other emergency situations it is necessary to provide emergency 
exit to evacuate people. For example, 

BH-02

 anti-panic rotary sections can be used as an 

emergency exit. 
The passageway of the swing gate can be used as an additional emergency exit. The construction 
of the gate allows providing exit without use of any special keys or tools. Apply 

Fire Alarm

 control 

signal to the control board. The swing panel will open automatically making the passage free 
regardless of the set operating mode. Other control commands will be ignored. The opening 
direction is defined by 

FireAlarmDir

 jumper on the control board. When the signal is turned off, the 

swing panel moves to 

“Closed”

 position and locks. 

Device sending 

Fire Alarm 

emergency unlocking signal is not included into standard delivery set. 

Besides, the swing gate is basically a normally open device, meaning that in case of power failure 
the swing panel can rotate manually ±90º, making the passage free. 

9.5  Troubleshooting 

Possible faults to be corrected by the user themselves are listed in Table 6. In an unlikely event of 
other faults please consult the 

PERCo

 Technical Support Department. 

Table 6. Troubleshooting  

Fault 

Possible cause 

Remedy 

When powered-up, 
RC-panel indication 
does not work 

No supply voltage on 
control board  

De-energize power supply unit. Remove the cover 
and housing of the gate. Check the power cable 
and its connection to the 

XT1

 terminal block. 

The gate cannot 
operate in one of the 
directions, RC-panel 
indication is on  

Control signal of 
chosen direction is 
not applied to the 
control board  

De-energize power supply unit. Remove the cover 
and housing of the gate. Check the cable of RC 
panel / WRC device / ACS controller and its 
connection to the 

XT2

 terminal block  

10 

TRANSPORTATION AND STORAGE 

The swing gate in the original package should be transported only in closed freight containers or 
other closed type cargo transport units.  
During storage and transportation boxes with swing gate posts can be stacked no more than 2 
layers high. Stacking of boxes with glass panels is not allowed. 
The swing gate should be stored in dry indoor facilities at ambient temperatures from –40°C to 
+50°C and at relative air humidity of up to 98% at +25°

С

After transportation or storage at below-zero temperatures or high air humidity, the swing gate 
should be kept unpacked for minimum 24 hours under normal climate conditions corresponding to 
operation conditions. 

11 

MAINTENANCE 

Technical maintenance of the swing gate should be performed only at 

PERCo

 service center.  

We recommend using liquid non-abrasive cleansers containing ammonia to clean a swing gate 
post and a glass panel when dirty. 

 

18 

Содержание WMD-06

Страница 1: ...ASSEMBLY AND OPERATION MANUAL WMD 06 Motorized Electromechanical Swing Gate ...

Страница 2: ...WMD 06 Motorized electromechanical swing gate Assembly and Operation Manual ...

Страница 3: ...QUIREMENTS 12 7 1 Installation safety 12 7 2 Operation safety 12 8 ASSEMBLY AND INSTALLATION 13 8 1 General recommendations 13 8 2 Tools and equipment required for installation 13 8 3 Appropriate cable length 13 8 4 Installation procedure 13 9 OPERATION 16 9 1 Power up 16 9 2 Pulse control mode 17 9 3 Potential control mode 17 9 4 Emergency situations 18 9 5 Troubleshooting 18 10 TRANSPORTATION AN...

Страница 4: ...sed as a separate device It is recommended to define the number of swing gates necessary to secure fast and convenient passage in accordance with throughput rate see Section 3 For example it is recommended to install one turnstile per 500 people on the basis of maximum working load of 12 persons min 2 OPERATING CONDITIONS The swing gate with regard to resistance to environmental exposure complies ...

Страница 5: ...0 mm passageway width is chosen by the customer RC panel with cable 1 SW1 5 Allen wrench 1 Gate mounting kit PFG IH 10 SORMAT Finland anchor bolt with washer and M10 nut 3 Panel installation kit M10 35 bolt 4 M10 nut 4 Spring washer 4 Expanded washer 8 Plastic bushing 4 Operational documentation Certificate 1 Assembly and operation manual 1 Template for gate installation 1 Package Box 1 gate post ...

Страница 6: ...electromagnetic stopper unit bearing units drive control board 6 RC panel is included into delivery set 17 The gate is operated with 24 V DC voltages via cable 13 The control board is installed inside the gate post The control board overview is shown in Fig 3 The control board contains XT1 and XT2 terminal blocks are designed for power supply input output of control signals and indication Marking ...

Страница 7: ...base 2 housing 3 cover 4 glass panel 5 metal ring 6 control board 7 rotary support 8 M3 screw 3 pcs 9 anchor stud bolt 10 M10 nut 11 washer 12 plastic ring 13 power cable 14 control cable from RC panel WRC device ACS controller 15 decorative plate 16 screw M4 17 RC panel 6 ...

Страница 8: ...trol board Terminal block No Item Designation 1 24 V 2 GND External power supply connection 3 NO 4 C 5 NC Light A relay contacts remote indicator connection for direction А 6 NO 7 C 8 NC Light B relay contacts remote indicator connection for direction В 9 12 V Power supply positive terminal of RC panel 10 GND Power supply negative terminal 11 Common Common contact for PASS А PASS В signals 12 Pass...

Страница 9: ...C panel features three control buttons to set swing gate passage modes The buttons LED indicators are located above The STOP button in the middle serves for setting the Always locked operating mode the RIGHT and LEFT buttons for allowing passage in the chosen direction The RC panel features a built in piezoelectric buzzer for audio signals generation The standard orientation of the RC panel in rel...

Страница 10: ...tput signals from rotation sensor Upon received data the microcontroller generates commands for the gate control mechanism and also signals for connected external indication devices indication on the RC panel Led A Led Stop and Led B signals on the performed rotation of the swing panel on outputs Pass А and Pass В 5 4 1 Inputs for control devices connection The swing gate can be operated with RC p...

Страница 11: ...be used as a control element If the Fire Alarm input is not used it is necessary to install a jumper between Fire Alarm and GND contacts on the XT2 terminal block The jumper is installed by default The gate can operate in two control modes pulse and potential Control mode is set by installing or removing the jumper on Imp Pot connector If the jumper is installed the gate operates in the pulse cont...

Страница 12: ...l specifications maximum switching voltage 42 V DC maximum switching current 0 25 А closed contact resistance max 0 15 Ohm 5 4 3 Outputs for external indication connection Light A and Light B outputs are used for external indication connection and are basically relay changeover contacts see Fig 9 Each output has full contact set on XT1 terminal block normally open NO normally closed NC and common ...

Страница 13: ...eing damaged during transportation and storage The box 1 contains gate post and RC panel the box 2 contains a swing panel Boxes have the marking of the packed product and additional marking in accordance with design documents and delivery set Dimensions L W H box 1 121 37 22 cm box 2 for AGG 650 glass panel 96 12 90 cm box 2 for AGG 900 glass panel 121 12 90 cm Gross weight box 1 max 36 kg box 2 f...

Страница 14: ... Appropriate cable length Maximum acceptable length of RC panel ACS controller cable 30 m Maximum acceptable length of power supply cable depends on its cross section and shall be as following for 1 5 mm2 cross section AWG 15 max 10 m for 2 5 mm2 cross section AWG 13 max 20 m 8 4 Installation procedure Attention The manufacturer shall not be liable for any damage caused in the result of improper i...

Страница 15: ...e the metal ring 5 Put a washer 11 on each anchor and fix the gate post with three M10 nuts 10 9 Connect power cable and control cable to XT1 and XT2 terminal blocks of the control board 6 Put cables as shown in Fig 3 10 If needed connect Fire Alarm emergency unlocking device If the device is not connected a wire jumper shall be installed on Fire Alarm and GND contacts on XT2 terminal block 11 If ...

Страница 16: ... of the swing gate 24V DC 4А А3 Power supply unit of remote indicators A4 A5 Remote indicators 2 pcs A6 1 ACS controller input A6 2 ACS controller output A7 Device sending Fire Alarm FA emergency unlocking signal A8 RC panel PERCo H6 4 A9 WRC device 1 Wire jumper Installed when the Fire Alarm device А7 is not connected Installed on default Not included in standard delivery set 15 ...

Страница 17: ...y cause mechanical damage or corrosion of the surfaces 9 1 Power up Attention Make sure that there are no obstacles in the rotation zone and passageway of the gate before starting the power up Perform the following actions in order 1 Connect the power cable to the electric socket with voltage and frequency set in the certificate of the power supply unit 2 Turn the power supply unit on 3 The swing ...

Страница 18: ...c in the Single passage in chosen direction mode Timing starts after the swing panel rotates 85º After that the swing panel moves to Closed position and locks the swing gate switches to the Always locked mode Single passage in chosen direction mode can be changed to Free passage mode in the same direction or to Always locked mode Always free mode can be changed to Always locked mode only 9 3 Poten...

Страница 19: ...t the PERCo Technical Support Department Table 6 Troubleshooting Fault Possible cause Remedy When powered up RC panel indication does not work No supply voltage on control board De energize power supply unit Remove the cover and housing of the gate Check the power cable and its connection to the XT1 terminal block The gate cannot operate in one of the directions RC panel indication is on Control s...

Страница 20: ...at the contact Unlock A while there is a low level at the contact Stop and a high level at the contact Unlock B or active front is at the contact Stop while there is a low level at the contact Unlock A and a high level at the contact Unlock B At this command the passage direction А opens until the command Always locked is received the status of the passage direction В does not change at that Free ...

Страница 21: ...PERCo Polytechnicheskaya str 4 block 2 194021 Saint Petersburg Russia Tel 7 812 247 04 64 E mail export perco com support perco com www perco com ...

Страница 22: ...www perco com ...

Отзывы: