5.5 Abnormal situations during gate operation
In a case of any impediment to the free rotation of the swing gate an automatic switching to
overload mode is provided. The mode is used to avoid damage to electromechanical elements due
to overheating.
If any obstacle impedes rotation of the swing panel, three attempts of rotation in the same direction
are made with 3 sec intervals. If the obstacle remains, the swing gate switches to overload mode.
Being in the overload mode the swing panel can rotate free ±90º that allows removing the obstacle.
In such case all three indicators on the RC panel are blinking, and a sound indication consisting of
three short audio signals is turned on each 20 sec.
The overload mode is switched off by rotating the swing panel into the “
Closed
” position manually
or by turning the power supply off and then on (in this case the gate will be set into home position
automatically).
6
MARKING AND PACKAGING
The swing gate has a marking label located inside the rotary post under the cover. The label
contains the trademark and contact details of the manufacturer, the manufacture date, voltage and
power consumption. To access to the marking take off the post cover by unscrewing three 3
screws using SW1.5 Allen wrench.
The swing gate in the standard package is packed in two boxes that protect it from being damaged
during transportation and storage. The box 1 contains gate post and RC panel, the box 2 contains
a swing panel. Boxes have the marking of the packed product and additional marking in
accordance with design documents and delivery set.
Dimensions, (L×W×H)
:
box 1 ................................................................................................................... 121×37×22
cm
box 2 for
AGG-650
glass panel ............................................................................ 96×12×90
cm
box 2 for
AGG-900
glass panel .......................................................................... 121×12×90
cm
Gross weight
:
box 1 ......................................................................................................................... max. 36
kg
box 2 for
AGG-650
swing panel ................................................................................ max. 28
kg
box 2 for
AGG-900
swing panel ................................................................................ max. 35
kg
7
SAFETY REQUIREMENTS
7.1 Installation safety
Installation should be performed by qualified personnel only, in strict accordance with the Manual
and general electrical safety requirements for electrical and installation work.
Attention!
All the connections should be performed only after the control unit is disconnected from
the power supply.
Only serviceable tools should be used.
Cables should be laid in accordance with electrical safety requirements.
Before first activation of the gate, check whether the installation and all connections are
performed correctly.
The installation of power supply unit shall be performed in accordance with general safety
requirements given in its operation manual.
7.2 Operation safety
Observe general safety requirements for use of electrical equipment.
Warning!
Do not use the swing gate in environment different from those given in Section 2.
Do not use the swing gate with power supply unit different from those given in Section 3.
Power supply unit shall be operated in accordance with general safety requirements given in its
operation manual.