IC-03.1 Card Capture Reader
17
9 POWER-UP
1. Check integrity and accuracy of all electrical connections.
2. Connect power supply unit to the mains with voltage and frequency given in its
Certificate.
3. Switch on the power supply unit. On the indication module (5) a yellow indicator:
card presentation is expected will light up which means that the card capture reader
is in the standby mode – initial state.
4. Check operation of the card capture reader together with the ACS controller in all
modes according to the operation algorithm (see Clauses 10.1, 10.2).
10 OPERATION INSTRUCTIONS
Attention!
When operation the equipment, observe precautions (Clause 7.2).
Warning! Don’ts:
•
dismantle and/or adjust operational units of the card capture reader;
•
clean the card capture reader with substances that may cause damage or
corrosion;
•
keep the card capture reader out of jerking and thrusting.
Control over indication of the built-in reader inside the card capture reader is made by the
ACS controller. Control signals in different modes are given in clause 5.5.
At the standby mode the operating device is blocked. Code reading is provided by
presenting cards to the reader and confirmed by momentary change of yellow LED
indicator.
10.1 Presenting a quest card
The guest card is presented by inserting it into the slot for cards capturing (6).
At the guest card presentation, considering that card is operative and its validity
corresponds to the time of passage, the ACS controller sends a signal to the card capture
reader to capture the card and switches into the
“Verification”
mode (waiting for the
“Card
captured”
signal from the card capture reader). It is recommended to apply the LED control
signal to indication module (5) for simultaneous blinking of green and red indicators at that.
In case of the ban on passage (card fault, card invalidity corresponding to the time of
passage or access wrights) the ACS controller does not switch to
“Verification”
mode. It is
recommended to switch on for 2 sec. the red indicator and sound signal on the indication
module at that. The ACS controller switches back to the standby mode after that.
Being in the
“Verification”
mode the ACS controller receives the “
Card captured
” signal at
the card falling into the card container. After receiving this signal the ACS controller will
unblock the operating device. It is recommended to switch on the green indicator on the
indication module at that showing authorization of passage. After that the ACS controller
blocks the operating device and switches back to the standby mode.
If at the
“Verification”
mode expiration the ACS controller does not receive the “
Card
captured
” signal from the reader it will not unblock the operating device. It is recommended
to switch on for 2 sec. the red indicator and sound signal on the indication module at that.
The ACS controller switches back to the standby mode after that. The missing of the signal