IC-03.1 Card Capture Reader
15
Attention!
Be extra cautious and careful when carrying out further works, make sure the card
capture reader does not fall until it is fixed in place.
9. Put the base (1) of the card capture reader to
A
zone. Match four holes in the base with
holes in the mounting surface. Fix the card capture reader with anchor bolts, controlling
its vertical position with a level gauge.
10. Pull the cables in the corresponding electric raceways.
11. Connect the cables (10)
1
7
, (11)
2
to the card capture reader control board located in its
upper part from the housing (3) side. Make connection according to wiring diagram
(see Figure ). The list elements designated in scheme shown in Table 4.
12. Connect the reader with the cable (12)
2
according to wiring diagram (see Figure 8).
When the reader is connected to the ACS controller as per the given diagram, external
control of the light indication in accordance with the “single-double” jumper position
(see Clause 5.6) and
Wiegand 26
output data format (orange wire – WF not
connected) are set up automatically.
Note:
When the cable between a reader and external controller is extended it is
recommended to arrange switching over of external control over LED indication and
format of output data in the connection place of a regular reader cable with an
extension cable.
12.1. If necessary to change the LED indication control mode into
«double line»
(Table 1) please cut the jumper on the backside of the built-in reader board.
12.2. To change a format of outcoming data of the
Wiegand
interface an orange wire
WF is used according to Table 2.
13. Install the housing (3) into operating position and fix it with screws. Install the card
container (9) into operating position by closing the lock (8). Install the cover (4) into
operating position by pushing it down carefully until it is fixed with pressure pads and
by adjusting its position in relation to the framework.
14. Check accuracy and integrity of all cables laid. Check accuracy and reliability of all
electrical connections of the card capture reader with power supply and ACS controller.
15. On completion of checking the card capture reader is ready for operation.
Table 4. Wiring diagram elements
Position
Name
Q-ty
A1
Card capture reader
IC-03.1
1
A2*
ACS controller
1
A3*
Power supply
1
1*
Card capture reader power cable
1
2*
Cable for ACS controller connection
1
3*
Cable for connection of the reader installed in a card capture reader
1
*
Equipment is not included in the standard set of delivery.
**
Can be connected to an ACS input.
1
Cables (9), (10) and (11) are not included in the standard delivery set