IC-03.1 Card Capture Reader
13
8.3 Cables parameters
Table 3. Recommended cable type for connection reader to external controller
№
cable
Connection
Max. length,
m
Cable type
Example
1
Card capture reader –
power supply
30
50
Twisted pair cable with
cross section min.
0.75 mm
2
2×0.75
2×1.5
2
Card capture reader –
ACS controller
40
24AWG – 18AWG
(0.2 – 0.8 mm
2
)
RAMCRO SA82BI-T,
CABS8/EC,
8C.SEC-SC,
W8ekw
3
Wiegand
connection
to ACS controller
Note:
Maximum distance between the reader and external controller depends on the cable
cross-section. For selecting the cable type please contact PERCo specialists. For
the given cable types reader performance after 40 m is not guaranteed.
8.4 Installation
Further installation instructions are given with the earlier mentioned recommendations
(see Clause 8.1) taken into account. Recommendations on preparation of mounting holes
in the mounting surface are given with regard to
“SORMAT”
anchor bolts for solid concrete
floors.
1. Unpack the card capture reader; check the delivery set completeness as per section 3
of the Certificate.
2. The card capture reader is placed at an exit from the territory before the OD. For easy
and handy service of the card capture reader during operation it is recommended to
place it so that there was free space of not less than 0,5 m
from its back panel’s side.
3. Mark out mounting holes following Figure 5 on the mounting surface for the card
capture reader installation, as well as mark electric raceways for the power cable (10)
1
,
cable for connection an ACS controller (11)
1
and cable for the reader’s data lines
connection (12)
1
to
A
zone of the cables input to the card capture reader with regard
to location of the power supply, ACS controller and OD.
Note:
Material, configuration, dimensions, wiring type (surface, buried, combined), position
at the entrance point and other characteristics of the electric raceways
are chosen
by the customer
in accordance with the entrance point features and layouts, other
operational factors.
1