Peqlab peqPOWER 300 Скачать руководство пользователя страница 4

Instruction Manual peqPOWER 300 Volt Power Supply 

WARNING 

Federal Communications Commission Advisory 
 
This equipment has been tested and found to comply with the limits for a Class A digital device, pursu-
ant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against 
harmful interference when the equipment is operated in a commercial environment. This equipment 
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance 
with the instruction manual, may cause harmful interference to radio communications. Operation of this 
equipment in a residential area is likely to cause harmful interference in which case the user will be re-
quired to correct the interference at their expense. Changes or modifications not expressly approved by 
the party responsible for compliance could void the user’s authority to operate the equipment. 

SAFETY INFORMATION 

Avoiding Electrical Shock 

The peqPOWER 300 Volt Power Supply produces up to 500 mA or 300 volts which are electrically iso-
lated from ground to reduce the risk of electrical shock to the user. Follow the guidelines below to ensure 
safe operation of the unit. 
The peqPOWER 300 Volt Power Supply has been designed for use with electrophoresis cells with 
shielded banana plugs thus minimizing any potential shock hazard to the user. Always use gel box sys-
tems that are compatible with the Power Supply, have been designed for your specific applications, and 
are suitable for the voltage and current range of the Power Supply. PEQLAB recommends against the 
use of gel box systems and / or power leads that have unshielded banana plugs. 
 
 

   To avoid electrical shock: 

1.

 

NEVER connect or disconnect wire leads from the power jacks when the red indicator light 
at the Start/Stop key is on or when “RUNNING” is displayed on the screen. 

2.

 

WAIT at least 5 seconds after stopping a run before handling output leads or connected ap-
paratus. 

3.

 

ALWAYS make sure that hands, work area, and instruments are clean and dry before mak-
ing any connections or operating the power supply. 

4.

 

ONLY connect the power supply to a properly grounded AC outlet. 

Avoiding Damage to the Instrument 

1.

 

For proper ventilation, leave at least 10 cm of space behind the instrument, and at least 5 
cm of space on each side. 

2.

 

Do not operate the power supply in high humidity environments (> 95%), or where conden-
sation may occur. 

3.

 

To avoid condensation after operating the power supply in a cold room, wrap the unit in a 
plastic bag and allow at least 2 hours for the unit to equilibrate to room temperature before 
removing the bag and operating the unit. 

Symbols 

Used on the peqPOWER 300 Volt Power Supply to indicate an area where a potential shock 
hazard may exist. 
 

PEQLAB_v0412_E 

1

Содержание peqPOWER 300

Страница 1: ...Instruction Manual 300 Volt Power Supply 0412E Creating the future together...

Страница 2: ......

Страница 3: ...RTED 6 IMPORTANT GUIDELINES 7 OPERATIONAL MODES 8 CHOOSING LIMITING PARAMETER SETTINGS 9 TROUBLESHOOTING 10 OPERATIONAL ELECTRICAL PARAMETERS 11 COMMON ERRORS FOUND WITH ELECTROPHORESIS POWER SUPPLIES...

Страница 4: ...shielded banana plugs thus minimizing any potential shock hazard to the user Always use gel box sys tems that are compatible with the Power Supply have been designed for your specific applications an...

Страница 5: ...ease check carefully that the shipment is complete and has not been dam aged in transit For missing parts or to report any kind of damage please contact PEQLAB see TECH NICAL SERVICE AND ORDERING INFO...

Страница 6: ...age and 4 negative voltage Operating Modes Constant Voltage 1 V step Constant Current 1 mA step Crossover Automatic Display type Backlit LCD Graphic type Display size 53 64 x 15 64 mm W x H Pause func...

Страница 7: ...f lab space The peqPOWER 300 Volt Power Supply offers two modes Constant Voltage or Constant Current Mode This manual describes the setup and operation of peqPOWER 300 Volt Power Supply including impo...

Страница 8: ...Supply PEQLAB_v0412_E 5 Description of Buttons and Switches Front View of peqPOWER 300 Volt Power Supply Rear View of peqPOWER 300 Volt Power Supply Control Buttons LCD Display Output Jacks Voltage Se...

Страница 9: ...nu meric values STOP START PAUSE CONSTANT MODE GETTING STARTED Installing the peqPOWER 300 Volt Power Supply 1 Check the label located near the AC inlet to ensure that the unit is compatible with loc...

Страница 10: ...the peqPOWER 300 Volt Power Supply by pressing the power switch the rear side of the instrument Upon start up the Display Screen on the front of the instrument will illuminate Use the START PAUSE and...

Страница 11: ...nual before starting electrophoresis using the peqPOWER 300 Volt Power Supply A basic Constant Voltage Current Mode operating procedure of the peqPOWER 300 Volt Power Sup ply is provided below We reco...

Страница 12: ...out the run providing a greater margin of safety over time The same voltage setting can be used regardless of the number or thickness of gels being proc essed Current Limiting Discontinuous buffer sys...

Страница 13: ...electrophoresis cell 5 Make sure buffers are prepared correctly and the recommended volume of buffer is added to the electrophoresis unit Operation stops with alarm The screen displays NO LOAD 6 High...

Страница 14: ...n Although the resistance is determined by the gel system the resistance can vary over the course of an electrophoretic separation Voltage The velocity with which an ion moves in an electric field wil...

Страница 15: ...uring a run Buffer leaking in a connected system Excessive temperature increase Excessive buffer evaporation Loose connection in a connected system Amperage set to low Change in constant mode Voltage...

Страница 16: ...arts are dried thoroughly before attempting to operate the unit Do not immerse the centrifuge in liquid or pour liquids over it Before using any cleaning or decontamination methods except those recomm...

Страница 17: ...ent Power Cat No peqPOWER 250 V 230 V 4 250 3000 mA 300 W 55 E250 230V peqPOWER 250 V 110 V 4 250 3000 mA 300 W 55 E250 110V For technical questions and more detailed information on PEQLAB s products...

Страница 18: ...WARRANTY OF MERCHANTABILITY For research use only Not intended for any animal or human therapeutic or diagnostic use EQUIPMENT DISPOSAL 15 This equipment is marked with the crossed out wheeled bin sym...

Страница 19: ......

Страница 20: ...QLAB Biotechnologie GmbH 6404 Polling Tel 43 0 5238 84 169 info peqlab at www peqlab at UK PEQLAB Ltd Southampton SO31 7ZN Freecall UK 0808 20 21 302 info peqlab co uk www peqlab co uk USA PEQLAB LLC...

Отзывы: