Instruction Manual peqPOWER 300 Volt Power Supply 

REPAIR AND MAINTENANCE 

Introduction 

The peqPOWER 300 Volt Power Supply requires no periodic maintenance program with the exception 
of an occasional dry wipe-down of the instrument. 

Encountering Problems 

1.

 

Check the troubleshooting section. 

2.

 

Call Technical Service. 

3.

 

If the unit must be shipped back for repair, contact PEQLAB for a decontamination form and 
shipping instructions. 

Cleaning 

Device and output jacks must be always clean. Before using any cleaning or decontamination methods 
except those recommended by the manufacturer, check with PEQLAB that the proposed method will not 
damage the equipment. To clean the centrifuge use a damp cloth and a mild, non-corrosive detergent 
(ph < 8). After cleaning, ensure all parts are dried thoroughly before attempting to operate the unit. Do 
not immerse the centrifuge in liquid or pour liquids over it. 

Disinfection 

In case disinfection gets necessary, clean the system with 70 % ethanol or IPA. After cleaning, ensure all 
parts are dried thoroughly before attempting to operate the unit. Do not immerse the centrifuge in liquid 
or pour liquids over it. 
 

Before using any cleaning or decontamination methods except those recommended by the manufac-
turer, check with PEQLAB that the proposed method will not damage the equipment.. 

 

Replacing the Fuse 

One extra fuse is supplied with the peqPOWER 300 Volt Power Supply. For additional fuses, contact 
PEQLAB’s Technical Service. 
To replace the fuse: 

1.

 

Turn off the main power switch at the rear of the peqPOWER 300 Volt Power Supply and de-
tach the power cord from the rear of the peqPOWER 300 Volt Power Supply. 

2.

 

Open the fuse compartment located inside the Power Entry Module by inserting a small flat 
blade screwdriver into the slot below the ON/OFF switch. Turn the screwdriver to gently pry 
open the fuse compartment. 
Note: The fuse compartment will not open with the power cord in place. 

3.

 

Pull the fuse holder out of the compartment and inspect the fuse. If the fuse is burned or there is 
a break in the fuse element, replace the fuse with an identical type of fuse (4A/250V) as pro-
vided in the fuse holder (see figure below). 

4.

 

Place the fuse holder back into the compartment. 

PEQLAB_v0412_E 

13

Содержание peqPOWER 300

Страница 1: ...Instruction Manual 300 Volt Power Supply 0412E Creating the future together...

Страница 2: ......

Страница 3: ...RTED 6 IMPORTANT GUIDELINES 7 OPERATIONAL MODES 8 CHOOSING LIMITING PARAMETER SETTINGS 9 TROUBLESHOOTING 10 OPERATIONAL ELECTRICAL PARAMETERS 11 COMMON ERRORS FOUND WITH ELECTROPHORESIS POWER SUPPLIES...

Страница 4: ...shielded banana plugs thus minimizing any potential shock hazard to the user Always use gel box sys tems that are compatible with the Power Supply have been designed for your specific applications an...

Страница 5: ...ease check carefully that the shipment is complete and has not been dam aged in transit For missing parts or to report any kind of damage please contact PEQLAB see TECH NICAL SERVICE AND ORDERING INFO...

Страница 6: ...age and 4 negative voltage Operating Modes Constant Voltage 1 V step Constant Current 1 mA step Crossover Automatic Display type Backlit LCD Graphic type Display size 53 64 x 15 64 mm W x H Pause func...

Страница 7: ...f lab space The peqPOWER 300 Volt Power Supply offers two modes Constant Voltage or Constant Current Mode This manual describes the setup and operation of peqPOWER 300 Volt Power Supply including impo...

Страница 8: ...Supply PEQLAB_v0412_E 5 Description of Buttons and Switches Front View of peqPOWER 300 Volt Power Supply Rear View of peqPOWER 300 Volt Power Supply Control Buttons LCD Display Output Jacks Voltage Se...

Страница 9: ...nu meric values STOP START PAUSE CONSTANT MODE GETTING STARTED Installing the peqPOWER 300 Volt Power Supply 1 Check the label located near the AC inlet to ensure that the unit is compatible with loc...

Страница 10: ...the peqPOWER 300 Volt Power Supply by pressing the power switch the rear side of the instrument Upon start up the Display Screen on the front of the instrument will illuminate Use the START PAUSE and...

Страница 11: ...nual before starting electrophoresis using the peqPOWER 300 Volt Power Supply A basic Constant Voltage Current Mode operating procedure of the peqPOWER 300 Volt Power Sup ply is provided below We reco...

Страница 12: ...out the run providing a greater margin of safety over time The same voltage setting can be used regardless of the number or thickness of gels being proc essed Current Limiting Discontinuous buffer sys...

Страница 13: ...electrophoresis cell 5 Make sure buffers are prepared correctly and the recommended volume of buffer is added to the electrophoresis unit Operation stops with alarm The screen displays NO LOAD 6 High...

Страница 14: ...n Although the resistance is determined by the gel system the resistance can vary over the course of an electrophoretic separation Voltage The velocity with which an ion moves in an electric field wil...

Страница 15: ...uring a run Buffer leaking in a connected system Excessive temperature increase Excessive buffer evaporation Loose connection in a connected system Amperage set to low Change in constant mode Voltage...

Страница 16: ...arts are dried thoroughly before attempting to operate the unit Do not immerse the centrifuge in liquid or pour liquids over it Before using any cleaning or decontamination methods except those recomm...

Страница 17: ...ent Power Cat No peqPOWER 250 V 230 V 4 250 3000 mA 300 W 55 E250 230V peqPOWER 250 V 110 V 4 250 3000 mA 300 W 55 E250 110V For technical questions and more detailed information on PEQLAB s products...

Страница 18: ...WARRANTY OF MERCHANTABILITY For research use only Not intended for any animal or human therapeutic or diagnostic use EQUIPMENT DISPOSAL 15 This equipment is marked with the crossed out wheeled bin sym...

Страница 19: ......

Страница 20: ...QLAB Biotechnologie GmbH 6404 Polling Tel 43 0 5238 84 169 info peqlab at www peqlab at UK PEQLAB Ltd Southampton SO31 7ZN Freecall UK 0808 20 21 302 info peqlab co uk www peqlab co uk USA PEQLAB LLC...

Отзывы: