![Pepperl+Fuchs IC-KP-B7-V95 Скачать руководство пользователя страница 89](http://html.mh-extra.com/html/pepperl-fuchs/ic-kp-b7-v95/ic-kp-b7-v95_manual_1527931089.webp)
Appendix B
20
13
-0
4
89
12.1.2
Assembly object (04h)
These instances are taken from classes 64h and 65h.
Class attributes (instance 0)
Output instance attributes (instances 100d-112d)
Output instance 100d - 8 bytes
Output instance 101d - 12 bytes
Output instance 102d - 32 bytes
Output instance 103d - 60 bytes
Attribute ID Name
Data type
Data content
Access
authoriza-
tion
1
Revision
UINT
2
Get
2
Max. instance
UINT
162
Get
100
I/O output instance
USINT
100
Get / Set
101
I/O output produce length
UINT
8
Get
102
I/O input instance
1
USINT
150
Get
103
I/O input consume length
UINT
8
Get
1. I/O input instance = I/O output in 50d
Attribute ID Name
Data type
Data content
Access
authoriza-
tion
3
Output data
USINT
[0-248]
0
Get
Bytes
Class, instance, attribute
Description
0 - 7
64h, 06d, 01h
Mixed mode [8]
Bytes
Class, instance, attribute
Description
0 - 11
64h, 06d, 02h
Mixed mode [12]
Bytes
Class, instance, attribute
Description
0 - 31
64h, 06d, 03h
Mixed mode [32]
Bytes
Class, instance, attribute
Description
0 - 59
64h, 06d, 04h
Mixed mode [60]