20
13
-0
4
24
Commands
7.1.6
Separated mode
Each IDENT channel is addressed using a separate input and separate output
instance. The advantage here is that data processing is simplified because
different IDENT channels do not have to process the data in the same memory
area.
7.1.7
Data length
Depending on the data length required, four different attributes with different
lengths are available for each input/output instance.
Class 64h and 65h, instance 1-6
Attributes 1-3 require fewer data bytes than attribute 4.
Channel 1
Channel 2
Channel 3
Channel 4
Channel
Output command object
Input command object
IDENTControl
Class 64h
Instance 03
d
Attributes 1-4
1
Class 65h
Instance 03
d
Attributes 1-4
1
Class 64h
Instance 05
d
Attributes 1-4
1
Class 65h
Instance 05
d
Attributes 1-4
1
Class 65h
Instance 01
d
Attributes 1-4
1
Class 64h
Instance 02
d
Attributes 1-4
1
Class 65h
Instance 02
d
Attributes 1-4
1
Class 64h
Instance 04
d
Attributes 1-4
1
Class 65h
Instance 04
d
Attributes 1-4
1
Class 64h
Instance 01
d
Attributes 1-4
1
Attribute ID
Data length
Maximum number of double words (4
bytes) that can be read/written at any one
time
1
8
1
2
12
2
3
32
7
4
60
14