Appendix A
20
13
-0
4
81
Sending a write command as an implicit command
2
Byte 8
Command code
04h
Command
CT
(Change tag)
Byte 9
Number of double words/
Channel/Toggle bit
04h
Channel = element = 2
Toggle bit = 0
Byte 10
Status
00h
Processing command.
Byte 11
Reply counter
02h
For every IDENT telegram,
the value on the reply counter
increases by 1.
byte 12
00h
Not used
Byte 13
00h
Not used
Byte 14
00h
Not used
Byte 15
00h
Not used
3
Byte 16
...
Byte 23
00h
No commands are
transmitted to channel 3.
4
Byte 24
...
Byte 31
00h
No commands are
transmitted to channel 4.
Ele-
ment
Implicit
telegram
Use
Con-
tents
Description
Note!
The input and output instances can be configured via the display. However,
setting should be performed via the program while the plant is operating to permit
easier replacement or extension to the plant.
Ele-
ment
Implicit
telegram
Use
Con-
tents
Description
1
Byte 0
Command code
40h
Command
SW
(Single write double words)
Byte 1
Number of double words/
Channel/Toggle bit
10h
1 double word = 4 bytes
Element defines the channel.
Toggle bit = 0
Byte 2
Address of double word
(high byte)
00h
Start address = 0
Byte 3
Address of double word
(low byte)
00h
Start address = 0
Byte 4
Data
00h
1. Byte data
Byte 5
Data
01h
2. Byte data
Byte 6
Data
02h
3. Byte data
Byte 7
Data
03h
4. Byte data