Appendix A
Send a Single readcommand to channel 3 as an implicit command:
A command confirmation appears in the input field:
Byte no.
Use
Contents Description
Byte 0
Command code
01h
Command
SF
(Single read read
only code)
Byte 1
Channel/Toggle bit
06h
Channel = 3
Toggle bit = 0
Byte 2
00h
Byte 3
00h
Byte 4
00h
Byte 5
00h
Byte 6
00h
Byte 7
00h
Byte 8
00h
Byte 9
00h
Byte 10
00h
Byte 11
00h
Byte no.
Use
Contents Description
Byte 0
Command code
01h
Command
SF
(Single read read
only code)
Byte 1
Channel/Toggle bit
06h
Channel = 3
Toggle bit = 0
Byte 2
Status
FFh
Processing command.
Byte 3
Reply counter
07h
For every IDENT telegram, the
value on the reply counter
increases by 1.
Byte 4
00h
Byte 5
00h
Byte 6
00h
Byte 7
00h
Byte 8
00h
Byte 9
00h
Byte 10
00h
Byte 11
00h