VB24
55
5.1
POWER SUPPLY
Power can be supplied to the scanner through the pins provided on the 25-pin connector used
for communication with the host (Figure 44):
Earth Ground
POWER SUPPLY
CHASSIS
VGND
V+ (10 - 30 Vdc)
13
25
1
Vdc
GND
CHASSIS
VB24
Figure 44 - Power Supply Connections
The power must be between 10 and 30 Vdc only.
It is recommended to connect pin 1 (CHASSIS) to a common earth ground.
5.2
MAIN SERIAL INTERFACE
The signals relative to the following serial interface types are available on the input/output
connector of VB24.
If the interface type is not compatible with the current communication handshaking, then the
system forces the handshake to
none
.
The main interface type and the relative parameters (baud rate, data bits, etc.) can be
set using the Genius™ utility program or the Genius™ based Host Mode
Programming procedure.
Details regarding the connections and use of the interfaces are given in the next paragraphs.
Содержание FUQ-B8
Страница 1: ...VB24 BARCODE SCANNER FABRIKAUTOMATION MANUAL ...
Страница 22: ...VB24 12 b Operating mode selection and definition c Digital Outputs configuration ...
Страница 42: ...VB24 32 Figure 16 Positioning with U Shape Mounting Bracket Pitch Skew 0 15 45 45 15 alignment marks ...
Страница 54: ...VB24 44 Figure 28 ID NET Network Connections with isolated power blocks Power Supply Power Supply Power Supply ...
Страница 55: ...VB24 45 Figure 29 ID NET Network Connections with Common Power Branch Network ...
Страница 56: ...VB24 46 Figure 30 ID NET Network Connections with Common Power Star Network ...
Страница 72: ...VB24 62 Figure 52 ID NET Network Connections with isolated power blocks Power Supply Power Supply Power Supply ...
Страница 73: ...VB24 63 Figure 53 ID NET Network Connections with Common Power Branch Network ...
Страница 74: ...VB24 64 Figure 54 ID NET Network Connections with Common Power Star Network ...
Страница 112: ...VB24 102 T Technical Features 108 Troubleshooting 105 Typical Layouts 77 ...