VB24
5
Step 3 – Focus the Scanner
The reading distance depends on the focus distance of the scanner and should be set
according to the application requirements. The Focus Position is set directly through the focus
adjustment screw on the front panel of the scanner. This screw moves the internal lens of the
scanner to change the focal length of the scanner. The setting is continuous but should not be
set beyond the limits "Too Far" or "Too Near" which appear on the display at the extremes of
the focus range. Although the scanner reads across the entire focus range, there are three
guaranteed positions which correspond to the reading diagrams in par. 7.4.
1.
Power up the scanner
.
Wait for the power up sequence to finish. By default the scanner focus is in
the Unlocked position. The alternating message on the display shows the mechanical Focus
Position.
2.
Using a screwdriver turn the focus adjustment screw in the desired direction, clockwise (focus nearer to
the scanner) or counterclockwise (focus farther from the scanner). The focus position in centimeters and
inches is shown on the scanner display.
NOTE
The value of the Focus Position must be stored in memory. If the mechanical position changes by
more than the allowed tolerance of the value in memory, an alarm will be sent. See the Focus
Lock function in step 4, Mode Configuration.
As an additional visual aid during focusing, the indicator LEDs show the relative focus position
as follows:
READY
GOOD
TRIGGER
COM
STATUS
SETUP
LEARN
TES T
FOCUS
READY
GOOD
TRIGGER
COM
STATUS
SETUP
LEARN
TES T
FOCUS
READY
GOOD
TRIGGER
COM
STATUS
SETUP
LEARN
TES T
FOCUS
less than 30 cm
30 cm NEAR
32-38 cm
READY
GOOD
TRIGGER
COM
STATUS
SETUP
LEARN
TES T
FOCUS
READY
GOOD
TRIGGER
COM
STATUS
SETUP
LEARN
TES T
FOCUS
READY
GOOD
TRIGGER
COM
STATUS
SETUP
LEARN
TES T
FOCUS
40 cm MEDIUM
42-58 cm
60 cm FAR
READY
GOOD
TRIGGER
COM
STATUS
SETUP
LEARN
TES T
FOCUS
more than 60 cm
Содержание FUQ-B8
Страница 1: ...VB24 BARCODE SCANNER FABRIKAUTOMATION MANUAL ...
Страница 22: ...VB24 12 b Operating mode selection and definition c Digital Outputs configuration ...
Страница 42: ...VB24 32 Figure 16 Positioning with U Shape Mounting Bracket Pitch Skew 0 15 45 45 15 alignment marks ...
Страница 54: ...VB24 44 Figure 28 ID NET Network Connections with isolated power blocks Power Supply Power Supply Power Supply ...
Страница 55: ...VB24 45 Figure 29 ID NET Network Connections with Common Power Branch Network ...
Страница 56: ...VB24 46 Figure 30 ID NET Network Connections with Common Power Star Network ...
Страница 72: ...VB24 62 Figure 52 ID NET Network Connections with isolated power blocks Power Supply Power Supply Power Supply ...
Страница 73: ...VB24 63 Figure 53 ID NET Network Connections with Common Power Branch Network ...
Страница 74: ...VB24 64 Figure 54 ID NET Network Connections with Common Power Star Network ...
Страница 112: ...VB24 102 T Technical Features 108 Troubleshooting 105 Typical Layouts 77 ...