background image

SPEEDEO

®

VA R I A B L E   S P E E D   P U M P  

VALID

ESC

VS

SB-PF-SPO-003C 

PENTAIR WATER SOLUTIONS      SB-CU-IMP-051F  

(this version 03/2019)

* SPEEDEO optimises the speed variation of the IntelliFlo pump and is 

compatible with variable speed pumps with an external connection 

which permits them to be externally controlled. The list of 

compatible pumps is constantly changing in accordance 

with releases of new models.

 01:03 Water:+24.3°C  

   Filtration:   V2

S1:OFF S2:ON   S3:OFF

AIR:+25.9°C

SPEEDEO

® 

EN

3 assignable outlets

4 controllable speeds

2 assignable inputs

1 Intelli BUS

IMPORTANT SAFETY INSTRUCTIONS,
READ AND FOLLOW ALL OF THE INSTRUCTIONS,
KEEP THESE INSTRUCTIONS

INSTALLATION AND USER GUIDE 

Содержание SPEEDEO SB-PF-SPO-003C

Страница 1: ...ernal connection which permits them to be externally controlled The list of compatible pumps is constantly changing in accordance with releases of new models 01 03 Water 24 3 C Filtration V2 S1 OFF S2...

Страница 2: ...ty excluding probes and consumables 2 years 2019 Pentair International LLC All rights reserved The document is subject to change without notice Trademarks and disclaimers Speedeo Soleo and Pentair are...

Страница 3: ...peeds Invertek convertor connection MENUS Main menu Radio menu Install Heating pump Information menu Filtration Length Filtration Speed Set Time CONNECTIONS Inlets Outlets Inlet connection for the end...

Страница 4: ...her conductors except if the conductors are also protected by a differential interrupter Refer to valid local codes for more details WARNING This product must be installed by an authorised or certifie...

Страница 5: ...em causing incorrect water chemistry which could harm people or equipment WARNING Consult the device display daily to ensure there are no alarm messages DANGER Water temperatures greater than 37 7 C 1...

Страница 6: ...operation is linked to a speed The rotation speeds at different speeds are directly pre set on the control unit drive of the pump SPEEDEO will therefore select the most appropriate power according to...

Страница 7: ...mber of visitors or by default or 30 value can be adjusted Possibility to change into SHOCK mode forcing of the filtration and electrolyser for 24 hours Possibility to change the speed according to th...

Страница 8: ...lator of acidic vapours and humidity circulating via the screw hole Fuse holder 1 A 250 VAC Status light for updates Elastomer cover Insulator of acidic vapours and humidity SPEEDEO automatically cont...

Страница 9: ...oom which cannot be accessed by children Set the device at a height lower than 2 m using three screws 4 to 5 mm diameter in appropriate plugs for the type of support and fix the device vertically on a...

Страница 10: ...device is permanently connected The power supply to the device is cut by its interrupter which must be close and must remain accessible at all times The device needs to be connected to the earth and i...

Страница 11: ...f installation types Controlling a solenoid valve with SPEEDEO makes it possible to benefit from full power for activities using V3 Opening the solenoid valve will stop the flows in the main circuit a...

Страница 12: ...select T Air to indicate that a temperature sensor is connected to the corresponding inlet INSTALLATION OF THE AIR TEMPERATURE PROBE OPTION If the air temperature probe is connected it automatically...

Страница 13: ...he diagram 2 Start the secured Install menu on the main menu press Esc and Valid at the same time for 3 secs A star appears in the top right corner of the home screen 3 On the Filtration Speed Type su...

Страница 14: ...he Filtration Speed Type sub menu select 3 speeds and hold down Valid HAYWARD VSTD Connections and functions ZODIAC FloPro VS Connections and functions 1 Connect the cables in accordance with the diag...

Страница 15: ...ain menu press Esc and Valid at the same time for 3 secs A star appears in the top right corner of the home screen 3 On the Filtration Speed Type sub menu select 4 speeds and hold down Valid This asse...

Страница 16: ...channel and at a distance maximum 30 m will automatically be paired If several different Combi installations are close to each other it is possible to shift the radio channel of one of the installati...

Страница 17: ...n Esc and Valid for 3 secs Astar appears in the top right corner of the home screen Access to restricted access mode Install Menu organisation Heating menu Information menu Heating pump Calibration An...

Страница 18: ...filtration according to the water temperature Menu Filtration Length daily Algorithm This control increases or decreases the filtration time TURBO increases the filtration time modifiable factory sett...

Страница 19: ...t Select current mode AUTO Automatically calculates the filtration length according to the water temperature ON Filtration runs 24 7 OFF Filtration stops note anti freeze mode becomes inactive TIMER F...

Страница 20: ...ting despite the setting of an hour from the start and or end of filtration if the cover does not cover the pool all day filtration will run all day 5 On the Filtration Speed Events Cover Open sub men...

Страница 21: ...orresponding outlet This contact is closed active outlet while the filtration is running whatever the rotation speed The connected control is guaranteed to function while the filtration pump is runnin...

Страница 22: ...enu Setpoint will then appear Select Setpoints to change the target value A menu Priority will then appear Select Priority to activate or not The priority will activate the filtration and heating pump...

Страница 23: ...nnect the cables in accordance with the diagram 2 Start the secured Install menu from the main menu simultaneously hold down Esc and Valid for 3 secs A star appears in the top right corner of the home...

Страница 24: ...th chosen terminal select OTHER to indicate that a motorised valve is connected to the corresponding outlet 1 Connect the cables in accordance with the diagram 2 Start the secured Install menu from th...

Страница 25: ...If filter washing is started manually the filtration time meter which activates automatic backwash is reset to zero Outlet connection for a pneumatic valve FILTER WASHING Valid to start washing Washin...

Страница 26: ...he filtration pump for the length of time entered into the Washing XX secs SPEEDEO starts the filtration pump for the length of time entered into the Rinsing field XX secs SPEEDEO supports you in wash...

Страница 27: ...ed filtration YES NO S2 timer YES NO S3 timer YES NO Cover open YES NO Heating YES NO S3 inlet 1 YES NO Filter washing Manual backwash Valid to start washing Filtration 100 h Washing 70 secs Rinsing 3...

Страница 28: ...emp water 25 1 C Temp air 27 8 C Antifreeze 3 C Information Firmware version Languages LANGUAGE FRANCAIS ENGLISH Update To update firmware insert the USB stick and hold down the Up key Radio Radio cha...

Страница 29: ...r lights up 5 2 In the main menu at the bottom under Information read the version no X X and check that it has changed 5 3 Replace the orange safety cover 5 4 Replace the soft cover 2 1 Remove the sof...

Страница 30: ...lorine Despite the excess dose of chlorine the water is just disinfected but by contrast it is saturated pH 8 5 Cl 0 2 mg ORP 500 mV The pH is so high that it cancels out the disinfectant effect of th...

Страница 31: ......

Страница 32: ...1004 LAUSANNE Switzerland Copyright Limited Licence except as specifically permitted herein no portion of the content of this document may be reproduced in any form or by any means without the prior...

Отзывы: