Installer Manual Riversoft - Programming
46 / 90
Ref. MKT-IM-045 / A - 13.03.2020
5.3.
Quick program guide
5.4. Time
of
day
Set the current time.
Parameter
description
Range of values
Default
value
Units of
measure
Notes
Time of day
0:00 - 23:59
12:00
hour:
minute
Brine dosage
0.2 - 6.0
0.6
kg
From 0.2 kg to 1.0 kg by increments
of 0.05 kg;
from 1.0 kg to 3.0 kg by increments of
0.1 kg;
from 3.0 kg to 6.0 kg by increments of
0.5 kg.
Volumetric
regeneration
0.4 - 9.5
3.6
m
3
From 0.4 m
3
to 1.0 m
3
by increments
of 0.05 m
3
;
from 1.0 m
3
to 3.0 m
3
by increments
of 0.1 m
3
;
from 3.0 m
3
to 5.0 m
3
by increments
of 0.2 m
3
;
from 5.0 m
3
to 9.5 m
3
by increments
of 0.5 m
3
.
Calendar override
0 - 30
3
day
0 = Disabled;
0.3 = Regeneration every 8 hours: at
2, 10 and 18 hours;
0.5 = Regeneration every 12 hours: at
2 and 14 hours;
1 - 30 = Regeneration every X days.
System selection
1 - 4
1
-
See 5.10. Regeneration cycles time,
page 48.
A
Press
until desired hour appears then release.
→ Range from 0 through 23 hours.
→ The elapsed minutes will reset to zero when the hours are
changed.
Содержание Riversoft
Страница 1: ...Riversoft Water Softener INSTALLER MANUAL WATER PURIFICATION...
Страница 61: ...Installer Manual Riversoft Maintenance Ref MKT IM 045 A 13 03 2020 61 90...
Страница 65: ...Installer Manual Riversoft Maintenance Ref MKT IM 045 A 13 03 2020 65 90...
Страница 73: ...Installer Manual Riversoft Maintenance Ref MKT IM 045 A 13 03 2020 73 90 PAGE INTENTIONALLY LEFT BLANK...
Страница 75: ...Installer Manual Riversoft Maintenance Ref MKT IM 045 A 13 03 2020 75 90...
Страница 77: ...Installer Manual Riversoft Maintenance Ref MKT IM 045 A 13 03 2020 77 90 turn turn Point 0 Point 0...
Страница 89: ...Installer Manual Riversoft Disposal Ref MKT IM 045 A 13 03 2020 89 90 PAGE INTENTIONALLY LEFT BLANK...
Страница 90: ...www pentairaquaeurope com...