24 V
06
Requirement for additional connected equipment:
- If you need to connect more equipment, the 4X Extension unit
can be linked (ref SB-PF-INA-001A, available as an option).
Supplementary inlets and outlets - (option with 4X Extension)
Possible connections on the 4 In inlets:
- Disabled:
Unused inlet, or makes it possible to disable an inlet which was previously used and to leave the
connection without any consequences.
- pH tank:
Affects the relevant input to a dry contact (normally open, the contact closes when there is no more
product) at a low level in the pH tank. In case of low level, the indoor display shows a symbol of a fuel pump in
front of the numerical pH value, an identical indicator appears on the internet account summary and an
e-mail is sent following the pre-set alert settings.
- RedOx tank:
Affects the relevant input to a dry contact (normally open, the contact closes when there is no
more product) at a low level in the disinfectant tank. In case of low level, the indoor display shows a symbol of
a fuel pump in front of the numerical RedOx value, an identical indicator appears on the internet account
summary and an e-mail is sent following the pre-set alert settings.
- Filtration stop:
Any closure of a dry contact on the relevant input will result in the filtration immediately
stopping.
- Pool cover:
Connecting a dry contact linked to closed sensor of a pool cover (the rolling shutter covers the
pool) automatically reduces daily duration production of a salt chlorinator.
- Not specified:
Connecting a dry contact has no effect on the operation of the technical room but allows you
to view, on the history menu, the activation time of a piece of equipment that you want to monitor (refilling, etc.)
as well as its real time status in the summary menu.
Possible connections to the 4 Aux outlets:
- Disabled:
Unused outlet, or makes it possible to disable an outlet which was previously used and to leave the
connection without any consequences.
- pH:
The relevant output closes a dry contact which makes it possible to control a pump which injects a pH
corrector. You must specify the type of pH- / pH + regulation in the relevant menu.
- If filtration is on:
The relevant output closes a dry contact when the filtration starts (useful for UV lamps).
- Aux:
The relevant output closes a dry contact
- Aux triggers filtration:
The closure of this output automatically conditions the filter to start.