18
Settings menu > Filtration menu
:
Control Center, filtration - connection and settings (Cont.)
This setting increases or decreases the filtration time to compensate
for the size of the pump and/or activity in the swimming pool. Factory
settings: Turbo = +30%, Eco = -30% (can be modified in the Instal.
menu).
Filter cleaning assistance: Washing > Filtration stop > Put into
washing po “enter” (position the 6-way valve to Wash then
press Valid) > Washing in progress > Filtration stop > Put into rinsing
po "enter” (position the 6-way valve to Rinse then press Valid )
> Rinse in progress > Filtration stop > Put into Filtration po
“enter” (position the 6-way to Filtration then press Valid).
Select current mode:
Auto
= Automatically calculates the filtration length according to the water temperature.
On
= Filtration runs 24/7.
Off
= The filtration is stopped (attention: the antifreeze mode is inactivated).
Schedule
= The filtration runs during each time period selected in the menu “Schedule Settings”
(see below)
Shock
= The SHOCK function triggers 24 hours of forced filtration and
electrolysis. This function can be useful after the pool has been used by
many visitors and when the pool temperature is high. At the end of
Shock mode, MAESTRO returns to Auto mode.
This menu gives you control of the filtration start and end time, to control the level of noise linked to your
pool (filtration noise), for the sake of the neighbourhood. By default, leave Stop on Auto. By ticking one of
the priorities, you accept that this controls filtration outside of the authorised time periods (because this
equipment needs to work when the filtration is working). If necessary, the filtration is re-started in 1-hour
cycles until the desired set point is obtained. In Auto mode, MAESTRO calculates the filtration finish time.
Auto On Off Schedule
Shock -Schedule cont.
-Cleaning -Filt. contr.
Filtration operation time slot
FILTRATION SCHEDULE
0123456789 10 11
AM: X X X
PM: XXXXXXXXXX
!!!!!!!!!!!!!!!!!!!!
!Put into position !
! Backwashing and “enter”!
!!!!!!!!!!!!!!!!!!!!
FILTRATION OPERATION TIME SLOT
Start: 08h End:21h
Priorities: RedOx:X
Heating: X pH:X
FILTRATION SET TINGS
Eco
Standard