Shutdown

22. Ensure chemical residue has been flushed from the hopper, and the rinse system valves are closed.

  

Before shutdown, follow steps 8-14 using clean water to rinse the container and sidewall. For sprayers 

equipped with a clean water rinse tank, follow the sprayer manufacturer’s instructions for pumping from the clean water 

tank during the final rinse. For transfer and tender truck installations, the final rinse should be made while transferring 

clean water.
23. Close the lid and lock it by turning it clockwise. Gently lift on the lid to ensure it is locked closed.
24. Close the HOPPER OUTLET VALVE.
25. Close the INLET VALVE.
26. If pump flow has been diverted to the Cleanload, divert it back for normal spraying or transfer.

ATTENTION

: Divert or stop all flow to and from the Cleanload system before performing any service or maintenance 

procedures.

ATTENTION

: Always wear proper Personal Protective Equipment when handling chemicals including gloves, eye 

protection, respirator and safety shoes.

ATTENTION

: Always dispose of chemicals and contaminated water in accordance with national and local laws and 

statutes.

Always flush the Cleanload with clean water after each day’s use, if switching chemicals, or if the system is going to 

be inactive for an extended period of time. Ensure that the components of the Cleanload are free of any chemical 

buildup or residue, both inside and out. Failing to properly clean the system could lead to reduced performance and 

component life.
Be sure to thoroughly clean the eductor, ball valves and hopper. Cycle the ball valves open and close during rinsing to 

ensure they are clean.

Daily Maintenance:

• Inspect all components for excessive wear, leaks or any other damage prior to each use. Careful inspection is

required before using the system after long periods of inactivity.

Yearly Maintenance:
Your Cleanload will last longer and give best performance when properly taken care of. Proper Cleanload care depends 

on the fluid/chemical being used and when the Cleanload will be used again. At the end of the spraying season, flush the 

Cleanload with a neutralizing solution for the fluid/chemical just used. Follow with a clean water rinse. This is especially 

important for corrosive chemicals. Drain Cleanload thoroughly, open all drain plugs, and plug all ports until Cleanload is 

used again.

- 9 -

- 8 -

Parts Illustration

3371-0036R 

Eductor (for Model 3376-0870) 

 

 

3371-0037R 

Eductor (for Model 3376-0871) 

3371-0038R 

Eductor (for Model 3376-1170) 

3371-0039R 

Eductor (for Model 3376-1171) 

 

 

3371-0040R 

Eductor (for Model 3376-1670) 

3371-0041R 

Eductor (for Model 3376-1671) 

PV1/2F1/2M-MA 

PC1/2F-36075 

7250-5000

    

4A 

4B 

4C 

4D 

4E 

7550-5028 

1700-0259

 

2800-003

1

 

1700-0254

 

3240-0009 

7250-5002  

ProClean Container Rinse 

Nozzle, ProClean Container Rinse 

Tank Valve

Valve Clamp 

Gasket 

Handle 

Red

 

Gasket 

Nut

UF Valve 

5A 

7550-5028 

Valve Clamp 

5B 

1700-0254

Gasket 

5C 

2800-0030 

Handle Yellow 

1

2

3

4

5

6

17

14

12

15

11

10

10

10

13

18

16

9 8

7

19

20

Ref. Qty.  Part 

No. Req’d.  Number 

Description

Ref. Qty.  Part 

No. Req’d.  Number 

Description

Start-Up, Operation, Shutdown - cont’d.

Information

Cleaning

Maintenance

Maintenance and Servicing

Tube kit No. 3430-0833 

 

Contains: Tubing (Ref. 18)(Ref. 19) 
(Ref. 20) one screw not shown, one hose 
clamp not shown.

4A & 5A

4B & 5B

4C & 5C

4D

4E 

TL16-0006

Lid 

Kit

3350-0180

Strainer

1700-0253

Grommet

2404-0413

Hose 

Barb 

Fitting

10 

2404-0414

Elbow 

Fitting 

(1/2”)

11 

3305-0113 

Two-way Valve (1/2”) 

12 

2404-0386

Fitting

13 

2404-0415

Tee 

Fitting 

(1/2”)

14 

1510-0128

Mounting 

Ring

15 

2210-0201

Hex 

Bolt, 

M6x1x25

16 

2210-0200

Hex 

Bolt, 

M6x1x80

17  1 1510-0127 

Bracket 

18 

3430-0833 

Tube Kit 

19 

3430-0833 

Tube Kit 

20 

3430-0833 

Tube Kit

NOTE: When ordering parts, give 
quantity, part number, description and 
complete model number. Reference 
numbers are used ONLY to identify 
parts in the drawing and are NOT to be 
used as order numbers.

CAUTION: Only use Genuine 

Hypro replacement parts.

Содержание HYPRO Cleanload 3376-0870

Страница 1: ...ction Manual Form L 1543 Rev D Pentair 375 5th Ave New Brighton MN 55112 Phone 651 766 6300 OR 800 424 9776 Fax 800 323 6496 www hypropumps com HYPRO Models 3376 0870 and 3376 0871 Models 3376 1170 an...

Страница 2: ...uction 3 Description 3 Purpose of Manual 3 Intended Use s 3 Misuses 3 Cleanload Details 4 Description of Workstation 4 Tools 5 Lifting Transport and Intermediate Storage 5 Assembly and Installation 5...

Страница 3: ...ssure Rate Rate PSI gal sec gal min 40 0 63 19 34 60 0 75 23 43 80 0 96 26 65 100 1 39 29 46 3376 1170 3376 1171 Input Eduction Flow Pressure Rate Rate PSI gal sec gal min 20 0 57 27 06 40 0 86 38 09...

Страница 4: ...e slightly out of the chemical but keep it in the container to let the lance drain out 19 Place the end of the lance into a container of clean rinse water Suction for 30 seconds or more to clean the l...

Страница 5: ...last longer and give best performance when properly taken care of Proper Cleanload care depends on the fluid chemical being used and when the Cleanload will be used again At the end of the spraying s...

Страница 6: ...with clean water and remove the fittings from both sides of the eductor Using a soft tool wood or plastic and taking care to not deform the orifice clear the blockage by pushing it back out toward the...

Страница 7: ...r any deviation from this document Return Procedures All products must be flushed of any chemical ref OSHA section 1910 1200 d e f g h and hazardous chemicals must be labeled tagged before being shipp...

Отзывы: