background image

- 11 -

Notes

- 10 -

Troubleshooting

Symptom 

Cause 

     Solution

Slow Eduction Rate 

Flow restrictions on outlet side of   Replace 90-degree fittings with sweeping  

 

eductor. 

 

 

 

bends using reinforced hose, especially   

 

    

 

 

 

near the eductor outlet. Use 2” (51mm) or  

 

    

 

 

 

larger hose and fittings all the way back to  

 

    

 

 

 

and into the tank. If sharp bends cannot be  

 

    

 

 

 

avoided, use oversized hose and fittings to  

 

 

 

    minimize 

flow 

restriction.

 

The eductor nozzle is plugged.  

Looking down into the hopper outlet with  

 

    

 

 

 

the hopper valve open, observe the liquid  

 

    

 

 

 

jet should be centered and straight. If it is  

 

    

 

 

 

off-center or if it is dispersed, flush the    

 

    

 

 

 

system with clean water and remove the  

 

    

 

 

 

fittings from both sides of the eductor.    

 

    

 

 

 

Using a soft tool (wood or plastic) and    

 

    

 

 

 

taking care to not deform the orifice, clear  

 

    

 

 

 

the blockage by pushing it back out toward  

 

    

 

 

 

the inlet side of the fitting. A blocked    

 

    

 

 

 

eductor nozzle indicates that a filtration   

 

    

 

 

 

problem elsewhere in the system must be  

 

 

 

    corrected.

Poor Lance Suction 

Granules may be too coarse.  

Coarse product may need to be poured into  

 

    

 

 

            the hopper.

 

Flow and pressure may be   

The lance functions best at the highest   

 

too low. 

 

 

 

operating pressures. See action for “Slow  

 

 

 

    Eduction 

Rate.”

Plugged Container Rinse Nozzle 

Debris in the Container Rinse 

Replace nozzle and make sure there is

 

system. 

 

 

 

proper filtration in the pump system before  

 

 

 

    the 

Cleanload 

inlet.

 

Leaks 

Loose fittings.  

 

 

Tighten fittings.

 

Cracked fittings. 

 

 

Replace fittings.

Содержание HYPRO Cleanload 3376-0870

Страница 1: ...ction Manual Form L 1543 Rev D Pentair 375 5th Ave New Brighton MN 55112 Phone 651 766 6300 OR 800 424 9776 Fax 800 323 6496 www hypropumps com HYPRO Models 3376 0870 and 3376 0871 Models 3376 1170 an...

Страница 2: ...uction 3 Description 3 Purpose of Manual 3 Intended Use s 3 Misuses 3 Cleanload Details 4 Description of Workstation 4 Tools 5 Lifting Transport and Intermediate Storage 5 Assembly and Installation 5...

Страница 3: ...ssure Rate Rate PSI gal sec gal min 40 0 63 19 34 60 0 75 23 43 80 0 96 26 65 100 1 39 29 46 3376 1170 3376 1171 Input Eduction Flow Pressure Rate Rate PSI gal sec gal min 20 0 57 27 06 40 0 86 38 09...

Страница 4: ...e slightly out of the chemical but keep it in the container to let the lance drain out 19 Place the end of the lance into a container of clean rinse water Suction for 30 seconds or more to clean the l...

Страница 5: ...last longer and give best performance when properly taken care of Proper Cleanload care depends on the fluid chemical being used and when the Cleanload will be used again At the end of the spraying s...

Страница 6: ...with clean water and remove the fittings from both sides of the eductor Using a soft tool wood or plastic and taking care to not deform the orifice clear the blockage by pushing it back out toward the...

Страница 7: ...r any deviation from this document Return Procedures All products must be flushed of any chemical ref OSHA section 1910 1200 d e f g h and hazardous chemicals must be labeled tagged before being shipp...

Отзывы: