6
c.
Set the amp meter
scale to at least 2 times
the pump motor full
load current.
d. Place the H-O-A switch
in the Hand position to
start the pump.
e. The meter should read
ap prox i mate ly 2 times
full load current during
starting.
f. After the motor has
started (within one
sec ond) the cur rent
should drop to a value
much less than full load
cur rent.
Typical
Motor Voltage
Component Lead Mode Reading
Main Winding
Black to
Start
Line Voltage
White
Main Winding
Black to
Run
Line Voltage
White
Start Winding
Black to
Start
Line Voltage
Red
Start Winding
Black to
Run
120%
Red
Line Voltage
5. Motor voltage check: