background image

2

 

• 

FLECK

 7000SXT Service Manual

TABLE OF CONTENTS

JOB SPECIFICATION SHEET ................................................3
INSTALLATION .....................................................................4
START-UP INSTRUCTIONS ..................................................5
TIMER FEATURES ................................................................5
TIMER OPERATION ..............................................................6
MASTER PROGRAMMING MODE CHART ............................7
MASTER PROGRAMMING MODE .........................................8
USER PROGRAMMING MODE ............................................11
DIAGNOSTIC PROGRAMMING MODE ................................12
POWERHEAD ASSEMBLY...................................................13
VALVE ASSEMBLY ..............................................................14
BYPASS ASSEMBLY............................................................15
SAFETY BRINE VALVE ........................................................16
TROUBLESHOOTING ..........................................................17
REMOVING GEAR BOX ASSEMBLY ....................................19
INSERTING CIRCUIT BOARD .............................................19
CONNECTING THE CIRCUIT BOARD .................................19
WATER CONDITIONER FLOW DIAGRAMS ........................20
INJECTOR FLOW DATA ......................................................21
METER FLOW DATA ............................................................22
DIMENSIONS......................................................................22

IMPORTANT PLEASE READ: 

• 

The information, specifications and illustrations in this 

manual are based on the latest information available at 

the time of printing. The manufacturer reserves the right 

to make changes at any time without notice.

• 

This manual is intended as a guide for service of the 

valve only. System installation requires information 

from a number of suppliers not known at the time of 

manufacture. This product should be installed by a 

plumbing professional.

• 

This unit is designed to be installed on potable water 

systems only.

• 

This product must be installed in compliance with all 

state and municipal plumbing and electrical codes. 

Permits may be required at the time of installation.

• 

It is established that when daytime water pressure is 

above 80 psi (5.5 bar), the maximum pressure rating of 

125 psi (8.6 bar) can be exceeded. A pressure regulator 

must be installed on this system or warranty is voided. 

• 

Do not install the unit where temperatures may drop 

below 32°F (0°C) or above 125°F (52°C).  

• 

Do not place the unit in direct sunlight. Black units will 

absorb radiant heat increasing internal temperatures. 

• 

Do not strike the valve or any of the components.

• 

Warranty of this product extends to manufacturing 

defects. Misapplication of this product may result in 

failure to properly condition water, or damage to product.

• 

A prefilter should be used on installations in which free 

solids are present. 

• 

In some applications local municipalities treat water with 

Chloramines. High Chloramine levels may damage  

valve components.

• 

Correct and constant voltage must be supplied to the 

control valve to maintain proper function.

CALIFORNIA PROPOSITION 65 WARNING

WARNING:

 This product contains chemicals known to 

the State of California to cause cancer or 

birth defects or other reproductive harm.

Содержание Fleck7000SXT

Страница 1: ...FLECK 7000SXT SERVICE MANUAL...

Страница 2: ...water systems only This product must be installed in compliance with all state and municipal plumbing and electrical codes Permits may be required at the time of installation It is established that wh...

Страница 3: ...gallon setting J 3 Ext Range 18 750 318 750 gallon setting K Electronic________Pulse Count________Meter Size 4 System Type A System 4 1 Tank 1 Meter Immediate or Delayed Regeneration B System 4 Time...

Страница 4: ...hould be the same size as the drain line flow control 4 Refer to the dimensional drawing for cutting height of the distributor tube If there is no dimensional drawing cut the distributor tube flush wi...

Страница 5: ...that continues to keep time and the passage of days for a minimum of 48 hours in the event of power failure During a power outage the control goes into a power saving mode It does not monitor water us...

Страница 6: ...mal step timing Control Operation During Programming The control only enters the Program Mode with the valve in service While in the Program Mode the control continues to operate normally monitoring w...

Страница 7: ...election SF rc cr SF Safety Factor Percentage off of gallon remaining capacity RC Fixed Reserve Capacity Fixed Gallon Amount CR Variable Reserve Changes the reserve based on previous day s water usage...

Страница 8: ...s in the unit Check and verify the choices selected in Master Programming Mode 1 Display Format Display Code DF This is the first screen that appears when entering Master Programming Mode The Display...

Страница 9: ...cifies what percentage of the system capacity will be held as a reserve Since this value is expressed as a percentage any change to the unit capacity or feedwater hardness that changes the calculated...

Страница 10: ...D5 D6 and D7 in the upper left hand corner of the display Set the value to ON to schedule a regeneration or OFF to skip regeneration for each day Use the Up and Down buttons to adjust the setting as n...

Страница 11: ...service and the time of day is NOT set to 12 01 PM 2 Use this display to adjust the Day Override This option setting is identified by DO in the upper left hand corner of the screen 3 Press the Extra C...

Страница 12: ...le buttons for five seconds while in service 2 Use this display to view the current Flow Rate This option setting is identified by FR in the upper left hand corner of the screen 3 Press the Up button...

Страница 13: ...Back Plate 10 3 40967 Screw Slotted Hx Wshr Hd 1 4 20 x 1 LG 11 5 13602 Screw Phil Rd Hd 6 32 x 5 16 12 1 12473 Screw Hx Wshr Hd 10 24 x 625 13 2 11805 Screw Rd Hd 4 40 x 5 8 Type POWERHEAD ASSEMBLY B...

Страница 14: ...4 3 0 gpm 61455 35 DLFC 3 4 3 5 gpm 61455 40 DLFC 3 4 4 0 gpm 61455 45 DLFC 3 4 4 5 gpm 61455 50 DLFC 3 4 5 0 gpm 61455 60 DLFC 3 4 6 0 gpm 61455 70 DLFC 3 4 7 0 gpm 61456 00 DLFC 1 Blank 61456 8 0 D...

Страница 15: ...Rev A 2 61562 Connector Assembly 1 1 2 NPT 7000 Brass 2 61562 10 Connector Assembly 1 1 2 BSP 7000 Brass 2 42241 01 Connector Assembly 1 1 2 NPT 7000 Plastic 2 42241 11 Connector Assembly 1 1 2 BSP 70...

Страница 16: ...kt Hd Set 10 24 x 75 4 1 19805 Nut Hex 10 24 Nylon Black 5 1 19652 01 Poppet Assy SBV w O ring 6 1 19649 Flow Dispenser 7 1 11183 O Ring 017 8 1 19647 Elbow Safety Brine Valve 9 2 19625 Nut Assy 3 8 P...

Страница 17: ...al through drain line Air in water system Assure that well system has proper air eliminator control Check for dry well condition Improperly sized drain line flow control Check for proper drain rate Ir...

Страница 18: ...it is measuring flow by running service water and watching for the flow indicator on the display If the unit does not measure flow verify that the meter cable is connected properly and that the meter...

Страница 19: ...the left side of the board with the flexible finger on the powerhead Apply pressure to the left while rotating the board back 41033 REV B Figure 4 2 When all the way down snap the circuit board into...

Страница 20: ...REV A 41121 REV A Backwash Position 40988 REV A 41121 REV A Brine Position 40988 REV A 41121 REV A Slow Rinse Position 40988 REV A 41121 REV A Second Backwash Position 40988 REV A 41121 REV A Rapid R...

Страница 21: ...FLECK 7000SXT Service Manual 21 INJECTOR FLOW DATA TR18755 REV B...

Страница 22: ...22 FLECK 7000SXT Service Manual METER FLOW DATA TR18753 Softener TR18688 Filter 41140 02 REV A 41023 REV C DIMENSIONS...

Страница 23: ...FLECK 7000SXT Service Manual 23...

Страница 24: ...trademarks and logos are the property of their respective owners Because we are continuously improving our products and services Pentair reserves the right to change specifications without prior notic...

Отзывы: