START-UP INSTRUCTIONS

The water softener should be installed with the inlet, 

outlet, and drain connections made in accordance with the 

manufacturer’s recommendations, and to meet applicable 

plumbing codes.
1.  Turn the manual regeneraton knob slowly in a clockwise 

direction until the program micro switch lifts on top of the 

first set of pins. Allow the drive motor to move the piston 

to the first regeneration step and stop. Each time the 

program switch position changes, the valve will advance to 

the next regeneration step. Always allow the motor to stop 

before moving to the next set of pins or spaces.

NOTE:   For electronic valves, please refer to the manual 

regeneration part of the timer operation section. 

If the valve came with a separate electronic timer 

service manual, refer to the timer operation section 

of the electronic timer service manual.

2.  Position the valve to backwash. Ensure the drain line flow 

remains steady for 10 minutes or until the water runs clear 

(see above).

3.  Position the valve to the brine / slow rinse position. Ensure 

the unit is drawing water from the brine tank (this step may 

need to be repeated).

4.  Position the valve to the rapid rinse position. Check the 

drain line flow, and run for 5 minutes or until the water 

runs clear.

5.  Position the valve to the start of the brine tank fill cycle. 

Ensure water goes into the brine tank at the desired rate. 

The brine valve drive cam will hold the valve in this position 

to fill the brine tank for the first regeneration.

6.  Replace control box cover.
7.  Put salt in the brine tank.

NOTE:   Do not use granulated or rock salt.

TIMER FEATURES

Parameter

Display

Data

Display

PM

Indicator

Flow Indicator

x1000 Indicator

Service

Icon

Programming

Icon

Extra Cycle

Button

Up

Button

Down

Button

Error/

Information

Icon

Figure 2  

Features of the SXT:

• 

Power backup that continues to keep time and the 

passage of days for a minimum of 48 hours in the event 

of power failure. During a power outage, the control 

goes into a power-saving mode. It does not monitor 

water usage during a power failure, but it does store the 

volume remaining at the time of power failure.

• 

Settings for both valve (basic system) and control type 

(method used to trigger a regeneration).

• 

Day-of-the-Week controls.

• 

While in service, the display alternates between time of 

day, volume remaining or days to regeneration, and tank 

in service (twin tank systems only).

• 

The Flow Indicator flashes when outlet flow is detected.

• 

The Service Icon flashes if a regeneration cycle has been 

queued.

• 

A Regeneration can be triggered immediately by pressing 

the Extra Cycle button for five seconds.

• 

The Parameter Display displays the current Cycle Step 

(B1, BD, B2, etc) during regeneration, and the data 

display counts down the time remaining for that cycle 

step. While the valve is transferring to a new cycle step, 

the display will flash. The parameter display will identify 

the destination cycle step (B1, BD, B2, etc) and the data 

display will read “----”. Once the valve reaches the cycle 

step, the display will stop flashing and the data display 

will change to the time remaining. During regeneration, 

the user can force the control to advance to the next cycle 

step immediately by pressing the extra cycle button.

Setting the Time of Day

1.  Press and hold either the Up or Down buttons until the 

programming icon replaces the service icon and the 

parameter display reads TD.

2.  Adjust the displayed time with the Up and Down buttons.
3.  When the desired time is set, press the Extra Cycle button 

to resume normal operation. The unit will also return to 

normal operation after 5 seconds if no buttons are pressed.

Queueing a Regeneration

1.  Press the Extra Cycle button. The service icon will flash to 

indicate that a regeneration is queued.

2.  To cancel a queued regeneration, press the Extra Cycle 

button.

Regenerating Immediately

Press and hold the Extra Cycle button for five seconds.

Содержание Fleck7000SXT

Страница 1: ...FLECK 7000SXT SERVICE MANUAL...

Страница 2: ...water systems only This product must be installed in compliance with all state and municipal plumbing and electrical codes Permits may be required at the time of installation It is established that wh...

Страница 3: ...gallon setting J 3 Ext Range 18 750 318 750 gallon setting K Electronic________Pulse Count________Meter Size 4 System Type A System 4 1 Tank 1 Meter Immediate or Delayed Regeneration B System 4 Time...

Страница 4: ...hould be the same size as the drain line flow control 4 Refer to the dimensional drawing for cutting height of the distributor tube If there is no dimensional drawing cut the distributor tube flush wi...

Страница 5: ...that continues to keep time and the passage of days for a minimum of 48 hours in the event of power failure During a power outage the control goes into a power saving mode It does not monitor water us...

Страница 6: ...mal step timing Control Operation During Programming The control only enters the Program Mode with the valve in service While in the Program Mode the control continues to operate normally monitoring w...

Страница 7: ...election SF rc cr SF Safety Factor Percentage off of gallon remaining capacity RC Fixed Reserve Capacity Fixed Gallon Amount CR Variable Reserve Changes the reserve based on previous day s water usage...

Страница 8: ...s in the unit Check and verify the choices selected in Master Programming Mode 1 Display Format Display Code DF This is the first screen that appears when entering Master Programming Mode The Display...

Страница 9: ...cifies what percentage of the system capacity will be held as a reserve Since this value is expressed as a percentage any change to the unit capacity or feedwater hardness that changes the calculated...

Страница 10: ...D5 D6 and D7 in the upper left hand corner of the display Set the value to ON to schedule a regeneration or OFF to skip regeneration for each day Use the Up and Down buttons to adjust the setting as n...

Страница 11: ...service and the time of day is NOT set to 12 01 PM 2 Use this display to adjust the Day Override This option setting is identified by DO in the upper left hand corner of the screen 3 Press the Extra C...

Страница 12: ...le buttons for five seconds while in service 2 Use this display to view the current Flow Rate This option setting is identified by FR in the upper left hand corner of the screen 3 Press the Up button...

Страница 13: ...Back Plate 10 3 40967 Screw Slotted Hx Wshr Hd 1 4 20 x 1 LG 11 5 13602 Screw Phil Rd Hd 6 32 x 5 16 12 1 12473 Screw Hx Wshr Hd 10 24 x 625 13 2 11805 Screw Rd Hd 4 40 x 5 8 Type POWERHEAD ASSEMBLY B...

Страница 14: ...4 3 0 gpm 61455 35 DLFC 3 4 3 5 gpm 61455 40 DLFC 3 4 4 0 gpm 61455 45 DLFC 3 4 4 5 gpm 61455 50 DLFC 3 4 5 0 gpm 61455 60 DLFC 3 4 6 0 gpm 61455 70 DLFC 3 4 7 0 gpm 61456 00 DLFC 1 Blank 61456 8 0 D...

Страница 15: ...Rev A 2 61562 Connector Assembly 1 1 2 NPT 7000 Brass 2 61562 10 Connector Assembly 1 1 2 BSP 7000 Brass 2 42241 01 Connector Assembly 1 1 2 NPT 7000 Plastic 2 42241 11 Connector Assembly 1 1 2 BSP 70...

Страница 16: ...kt Hd Set 10 24 x 75 4 1 19805 Nut Hex 10 24 Nylon Black 5 1 19652 01 Poppet Assy SBV w O ring 6 1 19649 Flow Dispenser 7 1 11183 O Ring 017 8 1 19647 Elbow Safety Brine Valve 9 2 19625 Nut Assy 3 8 P...

Страница 17: ...al through drain line Air in water system Assure that well system has proper air eliminator control Check for dry well condition Improperly sized drain line flow control Check for proper drain rate Ir...

Страница 18: ...it is measuring flow by running service water and watching for the flow indicator on the display If the unit does not measure flow verify that the meter cable is connected properly and that the meter...

Страница 19: ...the left side of the board with the flexible finger on the powerhead Apply pressure to the left while rotating the board back 41033 REV B Figure 4 2 When all the way down snap the circuit board into...

Страница 20: ...REV A 41121 REV A Backwash Position 40988 REV A 41121 REV A Brine Position 40988 REV A 41121 REV A Slow Rinse Position 40988 REV A 41121 REV A Second Backwash Position 40988 REV A 41121 REV A Rapid R...

Страница 21: ...FLECK 7000SXT Service Manual 21 INJECTOR FLOW DATA TR18755 REV B...

Страница 22: ...22 FLECK 7000SXT Service Manual METER FLOW DATA TR18753 Softener TR18688 Filter 41140 02 REV A 41023 REV C DIMENSIONS...

Страница 23: ...FLECK 7000SXT Service Manual 23...

Страница 24: ...trademarks and logos are the property of their respective owners Because we are continuously improving our products and services Pentair reserves the right to change specifications without prior notic...

Отзывы: