Problem

Cause 

Correction

Water conditioner fails to 

regenerate.

Electrical service to unit has been interrupted

Assure permanent electrical service (check fuse, plug, 

pull chain, or switch)

Timer is defective.

Replace timer.

Power failure.

Reset time of day.

Hard water.

By-pass valve is open.

Close by-pass valve.

No salt is in brine tank.

Add salt to brine tank and maintain salt level above water 

level.

Injector screen plugged.

Clean injector screen.

Insufficient water flowing into brine tank.

Check brine tank fill time and clean brine line flow 

control if plugged.

Hot water tank hardness.

Repeated flushings of the hot water tank is required.

Leak at distributor tube.

Make sure distributor tube is not cracked. Check O-ring 

and tube pilot.

Internal valve leak.

Replace seals and spacers and/or piston.

Unit used too much salt.

Improper salt setting.

Check salt usage and salt setting.

Excessive water in brine tank.

See "Excessive water in brine tank".

Loss of water pressure.

Iron buildup in line to water conditioner.

Clean line to water conditioner.

Iron buildup in water conditioner.

Clean control and add mineral cleaner to mineral bed. 

Increase frequency of regeneration.

Inlet of control plugged due to foreign material 

broken loose from pipes by recent work done on 

plumbing system.

Remove piston and clean control.

Loss of mineral through drain 

line.

Air in water system.

Assure that well system has proper air eliminator 

control. Check for dry well condition.

Improperly sized drain line flow control.

Check for proper drain rate.

Iron in conditioned water.

Fouled mineral bed.

Check backwash, brine draw, and brine tank fill. Increase 

frequency of regeneration. Increase backwash time.

Excessive water in brine tank.

Plugged drain line flow control.

Clean flow control.

Plugged injector system.

Clean injector and screen.

Timer not cycling.

Replace timer.

Foreign material in brine valve.

Replace brine valve seat and clean valve.

Foreign material in brine line flow control.

Clean brine line flow control.

Softener fails to draw brine.

Drain line flow control is plugged.

Clean drain line flow control.

Injector is plugged.

Clean injector

Injector screen plugged.

Clean screen.

Line pressure is too low.

Increase line pressure to 20 psi

Internal control leak

Change seals, spacers, and piston assembly.

Service adapter did not cycle.

Check drive motor and switches.

Control cycles continuously.

Misadjusted, broken, or shorted switch.

Determine if switch or timer is faulty and replace it, or 

replace complete power head.

Drain flows continuously.

Valve is not programming correctly.

Check timer program and positioning of control. Replace 

power head assembly if not positioning properly.

Foreign material in control.

Remove power head assembly and inspect bore. 

Remove foreign material and check control in various 

regeneration positions.

Internal control leak.

Replace seals and piston assembly.

TROUBLESHOOTING

Содержание Fleck7000SXT

Страница 1: ...FLECK 7000SXT SERVICE MANUAL...

Страница 2: ...water systems only This product must be installed in compliance with all state and municipal plumbing and electrical codes Permits may be required at the time of installation It is established that wh...

Страница 3: ...gallon setting J 3 Ext Range 18 750 318 750 gallon setting K Electronic________Pulse Count________Meter Size 4 System Type A System 4 1 Tank 1 Meter Immediate or Delayed Regeneration B System 4 Time...

Страница 4: ...hould be the same size as the drain line flow control 4 Refer to the dimensional drawing for cutting height of the distributor tube If there is no dimensional drawing cut the distributor tube flush wi...

Страница 5: ...that continues to keep time and the passage of days for a minimum of 48 hours in the event of power failure During a power outage the control goes into a power saving mode It does not monitor water us...

Страница 6: ...mal step timing Control Operation During Programming The control only enters the Program Mode with the valve in service While in the Program Mode the control continues to operate normally monitoring w...

Страница 7: ...election SF rc cr SF Safety Factor Percentage off of gallon remaining capacity RC Fixed Reserve Capacity Fixed Gallon Amount CR Variable Reserve Changes the reserve based on previous day s water usage...

Страница 8: ...s in the unit Check and verify the choices selected in Master Programming Mode 1 Display Format Display Code DF This is the first screen that appears when entering Master Programming Mode The Display...

Страница 9: ...cifies what percentage of the system capacity will be held as a reserve Since this value is expressed as a percentage any change to the unit capacity or feedwater hardness that changes the calculated...

Страница 10: ...D5 D6 and D7 in the upper left hand corner of the display Set the value to ON to schedule a regeneration or OFF to skip regeneration for each day Use the Up and Down buttons to adjust the setting as n...

Страница 11: ...service and the time of day is NOT set to 12 01 PM 2 Use this display to adjust the Day Override This option setting is identified by DO in the upper left hand corner of the screen 3 Press the Extra C...

Страница 12: ...le buttons for five seconds while in service 2 Use this display to view the current Flow Rate This option setting is identified by FR in the upper left hand corner of the screen 3 Press the Up button...

Страница 13: ...Back Plate 10 3 40967 Screw Slotted Hx Wshr Hd 1 4 20 x 1 LG 11 5 13602 Screw Phil Rd Hd 6 32 x 5 16 12 1 12473 Screw Hx Wshr Hd 10 24 x 625 13 2 11805 Screw Rd Hd 4 40 x 5 8 Type POWERHEAD ASSEMBLY B...

Страница 14: ...4 3 0 gpm 61455 35 DLFC 3 4 3 5 gpm 61455 40 DLFC 3 4 4 0 gpm 61455 45 DLFC 3 4 4 5 gpm 61455 50 DLFC 3 4 5 0 gpm 61455 60 DLFC 3 4 6 0 gpm 61455 70 DLFC 3 4 7 0 gpm 61456 00 DLFC 1 Blank 61456 8 0 D...

Страница 15: ...Rev A 2 61562 Connector Assembly 1 1 2 NPT 7000 Brass 2 61562 10 Connector Assembly 1 1 2 BSP 7000 Brass 2 42241 01 Connector Assembly 1 1 2 NPT 7000 Plastic 2 42241 11 Connector Assembly 1 1 2 BSP 70...

Страница 16: ...kt Hd Set 10 24 x 75 4 1 19805 Nut Hex 10 24 Nylon Black 5 1 19652 01 Poppet Assy SBV w O ring 6 1 19649 Flow Dispenser 7 1 11183 O Ring 017 8 1 19647 Elbow Safety Brine Valve 9 2 19625 Nut Assy 3 8 P...

Страница 17: ...al through drain line Air in water system Assure that well system has proper air eliminator control Check for dry well condition Improperly sized drain line flow control Check for proper drain rate Ir...

Страница 18: ...it is measuring flow by running service water and watching for the flow indicator on the display If the unit does not measure flow verify that the meter cable is connected properly and that the meter...

Страница 19: ...the left side of the board with the flexible finger on the powerhead Apply pressure to the left while rotating the board back 41033 REV B Figure 4 2 When all the way down snap the circuit board into...

Страница 20: ...REV A 41121 REV A Backwash Position 40988 REV A 41121 REV A Brine Position 40988 REV A 41121 REV A Slow Rinse Position 40988 REV A 41121 REV A Second Backwash Position 40988 REV A 41121 REV A Rapid R...

Страница 21: ...FLECK 7000SXT Service Manual 21 INJECTOR FLOW DATA TR18755 REV B...

Страница 22: ...22 FLECK 7000SXT Service Manual METER FLOW DATA TR18753 Softener TR18688 Filter 41140 02 REV A 41023 REV C DIMENSIONS...

Страница 23: ...FLECK 7000SXT Service Manual 23...

Страница 24: ...trademarks and logos are the property of their respective owners Because we are continuously improving our products and services Pentair reserves the right to change specifications without prior notic...

Отзывы: