TROUBLESHOOTING 

CONTINUED

Error Codes
NOTE:   Error codes appear on the In Service display.

Error Code

Error Type

Cause

Reset and Recovery

0

Cam Sense 

Error

The valve drive took longer than 

6 minutes to advance to the next 

regeneration position

Unplug the unit and examine the powerhead. Verify that all cam switches are 

connected to the circuit board and functioning properly. Verify that the motor 

and drive train components are in good condition and assembled properly. 

Check the valve and verify that the piston travels freely. Replace/reassemble 

the various components as necessary.

Plug the unit back in and observe its behavior. The unit should cycle to the 

next valve position and stop. If the error re-occurs, unplug the unit and 

contact technical support.

1

Cycle Step 

Error

The control experienced an 

unexpected cycle input

Unplug the unit and examine the powerhead. Verify that all cam switches 

are connected to the circuit board and functioning properly. Enter Master 

Programming mode and verify that the valve type and system type are set 

correctly with regard to the unit itself.

Step the unit through a manual regeneration and verify that it functions 

correctly. If the error re-occurs unplug the unit and contact technical 

support.

2

Regen 

Failure

The system has not regenerated 

for more than 99 days (or 7 days if 

the Control Type has been set to 

Day-of-Week)

Perform a Manual Regeneration to reset the error code. 

If the system is metered, verify that it is measuring flow by running service 

water and watching for the flow indicator on the display. If the unit does not 

measure flow, verify that the meter cable is connected properly and that the 

meter is functioning properly.

Enter a Master Programming Mode and verify that the unit is configured 

properly. As appropriate for the valve configuration, check that the correct 

system capacity has been selected, that the day override is set properly, 

and that meter is identified correctly. If the unit is configured as a Day-of-

Week system, verify that at least one day is set ON. Correct the settings as 

necessary.

3

Memory 

Error

Control board memory failure

Perform a Master Reset and reconfigure the system via Master Programming 

Mode. After reconfiguring the system, step the valve through a manual 

regeneration. If the error reoccurs, unplug the unit and contact technical 

support.

UD

Upper Drive 

Sync

Power failure/Programming has 

been changed.

Valve should recover automatically. If valve fails to come out of “UD”, check 

that the motor is cycling the gears. If not, you may have a jammed piston or 

a device motor that needs to be replaced. If the motor is cycling the gears, 

drain the super capacitor. Unplug the unit and press the rest button on the 

circuit board. Plug the unit back in and the display should be restored. The 

unit is ready for operation or programming.

No Display/

Backlight 

Only

No Display/

Backlight 

Only

Power Failure

Check that the transformer is putting out 24 volts AC. If the transformer is 

functioning properly, drain the super capacitor on the circuit board. Unplug 

the unit and press the reset button on the circuit board. Plug the unit back in 

and the display should be restored. 

Содержание Fleck7000SXT

Страница 1: ...FLECK 7000SXT SERVICE MANUAL...

Страница 2: ...water systems only This product must be installed in compliance with all state and municipal plumbing and electrical codes Permits may be required at the time of installation It is established that wh...

Страница 3: ...gallon setting J 3 Ext Range 18 750 318 750 gallon setting K Electronic________Pulse Count________Meter Size 4 System Type A System 4 1 Tank 1 Meter Immediate or Delayed Regeneration B System 4 Time...

Страница 4: ...hould be the same size as the drain line flow control 4 Refer to the dimensional drawing for cutting height of the distributor tube If there is no dimensional drawing cut the distributor tube flush wi...

Страница 5: ...that continues to keep time and the passage of days for a minimum of 48 hours in the event of power failure During a power outage the control goes into a power saving mode It does not monitor water us...

Страница 6: ...mal step timing Control Operation During Programming The control only enters the Program Mode with the valve in service While in the Program Mode the control continues to operate normally monitoring w...

Страница 7: ...election SF rc cr SF Safety Factor Percentage off of gallon remaining capacity RC Fixed Reserve Capacity Fixed Gallon Amount CR Variable Reserve Changes the reserve based on previous day s water usage...

Страница 8: ...s in the unit Check and verify the choices selected in Master Programming Mode 1 Display Format Display Code DF This is the first screen that appears when entering Master Programming Mode The Display...

Страница 9: ...cifies what percentage of the system capacity will be held as a reserve Since this value is expressed as a percentage any change to the unit capacity or feedwater hardness that changes the calculated...

Страница 10: ...D5 D6 and D7 in the upper left hand corner of the display Set the value to ON to schedule a regeneration or OFF to skip regeneration for each day Use the Up and Down buttons to adjust the setting as n...

Страница 11: ...service and the time of day is NOT set to 12 01 PM 2 Use this display to adjust the Day Override This option setting is identified by DO in the upper left hand corner of the screen 3 Press the Extra C...

Страница 12: ...le buttons for five seconds while in service 2 Use this display to view the current Flow Rate This option setting is identified by FR in the upper left hand corner of the screen 3 Press the Up button...

Страница 13: ...Back Plate 10 3 40967 Screw Slotted Hx Wshr Hd 1 4 20 x 1 LG 11 5 13602 Screw Phil Rd Hd 6 32 x 5 16 12 1 12473 Screw Hx Wshr Hd 10 24 x 625 13 2 11805 Screw Rd Hd 4 40 x 5 8 Type POWERHEAD ASSEMBLY B...

Страница 14: ...4 3 0 gpm 61455 35 DLFC 3 4 3 5 gpm 61455 40 DLFC 3 4 4 0 gpm 61455 45 DLFC 3 4 4 5 gpm 61455 50 DLFC 3 4 5 0 gpm 61455 60 DLFC 3 4 6 0 gpm 61455 70 DLFC 3 4 7 0 gpm 61456 00 DLFC 1 Blank 61456 8 0 D...

Страница 15: ...Rev A 2 61562 Connector Assembly 1 1 2 NPT 7000 Brass 2 61562 10 Connector Assembly 1 1 2 BSP 7000 Brass 2 42241 01 Connector Assembly 1 1 2 NPT 7000 Plastic 2 42241 11 Connector Assembly 1 1 2 BSP 70...

Страница 16: ...kt Hd Set 10 24 x 75 4 1 19805 Nut Hex 10 24 Nylon Black 5 1 19652 01 Poppet Assy SBV w O ring 6 1 19649 Flow Dispenser 7 1 11183 O Ring 017 8 1 19647 Elbow Safety Brine Valve 9 2 19625 Nut Assy 3 8 P...

Страница 17: ...al through drain line Air in water system Assure that well system has proper air eliminator control Check for dry well condition Improperly sized drain line flow control Check for proper drain rate Ir...

Страница 18: ...it is measuring flow by running service water and watching for the flow indicator on the display If the unit does not measure flow verify that the meter cable is connected properly and that the meter...

Страница 19: ...the left side of the board with the flexible finger on the powerhead Apply pressure to the left while rotating the board back 41033 REV B Figure 4 2 When all the way down snap the circuit board into...

Страница 20: ...REV A 41121 REV A Backwash Position 40988 REV A 41121 REV A Brine Position 40988 REV A 41121 REV A Slow Rinse Position 40988 REV A 41121 REV A Second Backwash Position 40988 REV A 41121 REV A Rapid R...

Страница 21: ...FLECK 7000SXT Service Manual 21 INJECTOR FLOW DATA TR18755 REV B...

Страница 22: ...22 FLECK 7000SXT Service Manual METER FLOW DATA TR18753 Softener TR18688 Filter 41140 02 REV A 41023 REV C DIMENSIONS...

Страница 23: ...FLECK 7000SXT Service Manual 23...

Страница 24: ...trademarks and logos are the property of their respective owners Because we are continuously improving our products and services Pentair reserves the right to change specifications without prior notic...

Отзывы: