 Model ProFloSXT Downflow Service Manual 

• 

5

STARTUP INSTRUCTIONS

The water softener should be installed with the inlet, 

outlet, and drain connections made in accordance with the 

manufacturer’s recommendations, and to meet applicable 

plumbing codes.
1.  Turn the manual regeneraton knob slowly in a clockwise 

direction until the program micro switch lifts on top of the 

first set of pins. Allow the drive motor to move the piston 

to the first regeneration step and stop. Each time the 

program switch position changes, the valve will advance to 

the next regeneration step. Always allow the motor to stop 

before moving to the next set of pins or spaces.

NOTE:   

For electronic valves, please refer to the manual 

regeneration part of the timer operation section. 

If the valve came with a separate electronic timer 

service manual, refer to the timer operation section 

of the electronic timer service manual.

2.  Position the valve to backwash. Ensure the drain line flow 

remains steady for 10 minutes or until the water runs clear 

(see above).

3.  Position the valve to the brine / slow rinse position. Ensure 

the unit is drawing water from the brine tank (this step may 

need to be repeated).

4.  Position the valve to the rapid rinse position. Check the 

drain line flow, and run for 5 minutes or until the water 

runs clear.

5.  Position the valve to the start of the brine tank fill cycle. 

Ensure water goes into the brine tank at the desired rate. 

The brine valve drive cam will hold the valve in this position 

to fill the brine tank for the first regeneration.

6.  Replace control box cover.
7.  Put salt in the brine tank.

NOTE:   

Do not use granulated or rock salt.

TIMER FEATURES

Parameter

Display

Data

Display

PM

Indicator

Flow Indicator

x1000 Indicator

Service

Icon

Programming

Icon

Extra Cycle

Button

Up

Button

Down

Button

Error/

Information

Icon

Features of the SXT

•  Power backup that continues to keep time and the 

passage of days for a minimum of 48 hours in the event 

of power failure. During a power outage, the control 

goes into a power-saving mode. It does not monitor 

water usage during a power failure, but it does store the 

volume remaining at the time of power failure.

•  Settings for both valve (basic system) and control type 

(method used to trigger a regeneration).

•  Day-of-the-Week controls.
•  While in service, the display alternates between time of 

day, volume remaining or days to regeneration, and tank 

in service (twin tank systems only).

•  The Flow Indicator flashes when outlet flow is detected.
•  The Service Icon flashes if a regeneration cycle has  

been queued.

•  A Regeneration can be triggered immediately by pressing 

the Extra Cycle button for five seconds.

•  The Parameter Display displays the current Cycle Step 

(BW, BF, RR, etc) during regeneration, and the data 

display counts down the time remaining for that cycle 

step. While the valve is transferring to a new cycle step, 

the display will flash. The parameter display will identify 

the destination cycle step (BW, BF, RR, etc) and the data 

display will read “----”. Once the valve reaches the cycle 

step, the display will stop flashing and the data display 

will change to the time remaining. During regeneration, 

the user can force the control to advance to the next cycle 

step immediately by pressing the extra cycle button.

Setting the Time of Day

1.  Press and hold either the Up 

or

 Down buttons until the 

programming icon replaces the service icon and the 

parameter display reads TD.

2.  Adjust the displayed time with the Up and Down buttons.
3.  When the desired time is set, press the Extra Cycle button 

to resume normal operation. The unit will also return to 

normal operation after 5 seconds if no buttons are pressed.

Содержание FLECK PROFLOSXT DOWNFLOW

Страница 1: ...www pentairaqua com FLECK MODEL PROFLOSXT DOWNFLOW SERVICE MANUAL...

Страница 2: ...mbing professional This unit is designed to be installed on potable water systems only This product must be installed in compliance with all state and municipal plumbing and electrical codes Permits m...

Страница 3: ...low A Downflow B Upflow C Upflow Variable 3 Meter Size A 3 4 inch Elec Paddlewheel B 3 4 inch Elec Turbine 4 System Type A System 4 1 Tank 1 Meter Immediate or Delayed Regeneration B System 4 Time Clo...

Страница 4: ...for cutting height of the distributor tube If there is no dimensional drawing cut the distributor tube flush with the top of the tank 5 Lubricate the distributor o ring seal and tank o ring seal Plac...

Страница 5: ...Indicator Service Icon Programming Icon Extra Cycle Button Up Button Down Button Error Information Icon Features of the SXT Power backup that continues to keep time and the passage of days for a minim...

Страница 6: ...the Extra Cycle button during a regeneration cycle immediately advances the valve to the next cycle step position and resumes normal step timing Control Operation During Programming The control only...

Страница 7: ...ty Factor Percentage of the system capacity to be used as a reserve RC Fixed Reserve Capacity Fixed volume to be used as a reserve DO Day Override The system s day override setting RT Regen Time The t...

Страница 8: ...entering Master Programming Mode The Display Format setting specifies the unit of measure that will be used for volume and how the control will display the Time of Day This option setting is identifi...

Страница 9: ...ING MODE CONTINUED 9 Safety Factor Display Code SF Press the Extra Cycle button Use this display to set the Safety Factor This setting specifies what percentage of the system capacity will be held as...

Страница 10: ...on for each day Use the Up and Down buttons to adjust the setting as needed Press the Extra Cycle button to accept the setting and move to the next day Note that the control requires at least one day...

Страница 11: ...s while in service and the time of day is NOT set to 12 01 PM 2 Use this display to adjust the Day Override This option setting is identified by DO in the upper left hand corner of the screen 3 Press...

Страница 12: ...in service 2 Press the Up button Use this display to view the current Flow Rate This option setting is identified by FR in the upper left hand corner of the screen 3 Press the Up button Use this displ...

Страница 13: ...42637 LABEL DISPLAY SXT 8 1 18260 COVER FRONT 9 1 19927 CAM D F SXT 10 1 18211 01 GEAR MAIN DOWNFLOW MACHD 11 1 18228 CAM BRINE VALVE 12 1 18202 BACK PLATE 13 1 40251 MOTOR 24v 50 60hz 14 2 13602 SCRE...

Страница 14: ...14 FLECK Model ProFloSXT Downflow Service Manual CONTROL VALVE ASSEMBLY...

Страница 15: ...lug Injector 27 2 13771 O ring 012 28 1 18275 X Throat Injector specify size 000 00 0 1 2 3 29 1 18274 X Nozzle Injector specify size 000 00 0 1 2 3 30 1 18273 Vortex Generator 31 1 18271 Screen Injec...

Страница 16: ...2 19569 Clip Flow Meter 3 1 19797 Meter Body Assembly 3 4 inch Turbine 4 4 13305 O ring 119 5 1 19791 01 Harness Assembly Flow Meter 1 19791 02 Meter Cable Assy 35 inch 6 19797 Meter 3 4 Turbine No C...

Страница 17: ...4 inch NPT Plastic 4B 1 13708 40 Yoke 1 inch Sweat 13708 45 Yoke 3 4 inch Sweat 19275 Yoke Angle 90 Deg 3 4 inch NPT 19275 45 Yoke Angle 90 Deg 3 4 inch Sweat 19620 01 Yoke Assy 3 4 inch R Angle 90 De...

Страница 18: ...11978 Plate Bypass Top 5 1 13604 01 Label Bypass Standard Mount 6 8 15727 Screw Hex Wsh Hd 10 24 x 1 2 7 1 11986 Plate Bypass Bottom For Service Assembly Numbers See the Back of this Manual 8 1 11979...

Страница 19: ...0 Fitting Sleeve 3 8 Celcon 7 1 10329 Fitting Tube 3 8 Nut Brass 8 1 10186 Nut Hex 10 32 9 1 60002 34 Air Check 500 34 inch Long 60003 34 Air Check 500 HW 34 inch Tube 10 1 10149 Rod Float 11 1 10700...

Страница 20: ...24 Nylon Black 5 1 19652 01 Poppet Assy SBV w O ring 6 1 19649 Flow Dispenser 7 1 11183 O ring 017 8 1 19647 Elbow Safety Brine Valve For Service Assembly Numbers See the Back of this Manual 9 2 19625...

Страница 21: ...e A Air in water system A Assure that well system has proper air eliminator control Check for dry well condition B Improperly sized drain line flow control B Check for proper drain rate 6 Iron in cond...

Страница 22: ...e been more than 99 days since the last Regeneration If the Day of the Week mode of regeneration is selected and days since last regeneration exceeds 7 days Regeneration must occur for the unit to rec...

Страница 23: ...FLECK Model ProFloSXT Downflow Service Manual 23 WATER CONDITIONER FLOW DIAGRAMS Service Position Backwash Position Brine Slow Rinse Position Rapid Rinse Position Brine Tank Fill Position...

Страница 24: ...24 FLECK Model ProFloSXT Downflow Service Manual FLOW DATA INJECTOR DRAW SLOW RINSE RATES...

Страница 25: ...FLECK Model ProFloSXT Downflow Service Manual 25 DIMENSIONAL DRAWING...

Страница 26: ...LACK ORANGE WT BLK BLACK WHITE GREEN BLUE BLUE WHITE BLUE WHITE BLUE PURPLE ORANGE BLACK WT BLK YELLOW BLACK BROWN METER P1 S N N H S VDO P2 N O H PWR H S CB1 50 60 HZ CB1 SXT Timer T1 24V Transformer...

Страница 27: ...e control in the Backwash position 9 Plug electrical cord into outlet 10 Set Time Of Day and cycle the control valve manually to assure proper function Make sure control valve is returned to the In Se...

Страница 28: ...y builds in the conditioner NOTE Be sure to shut off any bypass line 8 Replace the control valve back cover 9 Follow Injectors Screen Replacement steps 9 12 Meter Replacement To replace meter refer to...

Страница 29: ...INCHTUBE 60795 02 DISTRIBUTOR ASSY 1 INCH NARROW RED 008 W 72 INCH TUBE DRAIN LINE FLOW CONTROLS 60705 XX DRAIN LINE FLOW CONTROL FROM 6 7 0 GPM 60706 XX DRAIN LINE FLOW CONTROL W QUICK CONNECT FROM...

Страница 30: ...10 1 INCH BSP 13398NP 1 INCH NPT NICKEL PLATED 13398 10NP 1 INCH BSP NICKEL PLATED 18706 1 INCH PLASTIC MNPT 18706 10 1 INCH PLASTIC MBSP 18706 02 3 4 INCH PLASTIC MNPT 18706 12 3 4 INCH PLASTIC MBSP...

Страница 31: ...FLECK Model ProFloSXT Downflow Service Manual 31...

Страница 32: ...emarks and logos are the property of their respective owners Because we are continuously improving our products and services Pentair reserves the right to change specifications without prior notice Pe...

Отзывы: