Installer manual Fleck 3150 NXT/NXT2 - System sizing
30 / 182
Ref. MKT-IM-010 / C - 18.10.2019
140
53.8
5.38
3.01
150
55.5
5.55
3.1
170
58.5
5.85
3.27
200
62.7
6.27
3.5
230
66.9
6.69
3.74
260
71
7.1
3.97
290
75.3
7.53
4.21
To calculate the system mass capacity:
M
capacity
= V
resin
× C
resin ex
with:
M
capacity
: system mass capacity [g as CaCO
3
]
V
resin
: volume of resin [L]
C
resin ex
: resin exchange capacity [g/L
resin
as
CaCO
3
]
To calculate the system combined capacity:
C
capacity
= V
resin
× C
cor resin ex
with:
C
capacity
: system combined capacity [°f.m
3
or
°dH.m
3
]
V
resin
: volume of resin [L]
C
cor resin ex
: corresponding resin exchange
capacity [°f.m
3
/l or °dH.m
3
/l]
To calculate the system volume capacity:
V
capacity
= M
capacity
/ TH
inlet
Or
V
capacity
= C
capacity
/ TH
inlet
with:
V
capacity
: system volume capacity [m
3
]
M
capacity
: system mass capacity [g as CaCO
3
]
C
capacity
: system combined capacity [°f.m
3
or
°dH.m
3
]
TH
inlet
: inlet water hardness [mg/L as CaCO
3
or
°f or °dH]
CAUTION
If a mixing device is set on the valve before meter, TH = TH
INLET
- TH
OUTLET
.
Having determined the previous capacity allows the operator to know the service cycle
duration.
Содержание FLECK 3150 NXT
Страница 1: ...FLECK 3150 NXT NXT2 INSTALLER MANUAL WATER PURIFICATION ...
Страница 137: ...Installer manual Fleck 3150 NXT NXT2 Maintenance Ref MKT IM 010 C 18 10 2019 137 182 AC motor DC motor ...
Страница 139: ...Installer manual Fleck 3150 NXT NXT2 Maintenance Ref MKT IM 010 C 18 10 2019 139 182 DC motor ...
Страница 141: ...Installer manual Fleck 3150 NXT NXT2 Maintenance Ref MKT IM 010 C 18 10 2019 141 182 AC motor DC motor ...
Страница 144: ...Installer manual Fleck 3150 NXT NXT2 Maintenance 144 182 Ref MKT IM 010 C 18 10 2019 ...
Страница 148: ...Installer manual Fleck 3150 NXT NXT2 Maintenance 148 182 Ref MKT IM 010 C 18 10 2019 ...
Страница 182: ...www pentairaquaeurope com ...