Installer manual Fleck 3150 NXT/NXT2 - Programming
106 / 182
Ref. MKT-IM-010 / C - 18.10.2019
6.2.5.22
Day override/time driven
Set the maximum number of days between two regenerations regardless from any
other regeneration triggering type that could be programmed.
Info
For a timeclock valve, this value must be set as regeneration period in hours or days.
Info
For metered valves, this value can be set in days only.
Info
Not available if the regeneration type programmed is Day of week mode.
a) Adjust the number of days with
and
;
ð
Can be adjusted with 4H, 8H, 12H, 16H, 20H or
from 1 to 99 days for timeclock regeneration and
from OFF to 99 days for metered regeneration;
b) Press to validate the selection and advance to the
next parameter.
Calendar override
deactivated.
Override every 3 days.
6.2.5.23
Regeneration time
Set the time for regeneration start.
Info
Depending on regeneration mode programmed, this parameter may be displayed or
not.
a) Adjust the time of regeneration with
,
and ;
b) Can be adjusted from: 00:00 to 23:59HR;
c) Press to validate the selection and advance to the
next parameter.
6.2.5.24
Lock setting
Set Lock Window settings: Enable lock windows then select the desired Lock Start time
and Lock End time.
Содержание FLECK 3150 NXT
Страница 1: ...FLECK 3150 NXT NXT2 INSTALLER MANUAL WATER PURIFICATION ...
Страница 137: ...Installer manual Fleck 3150 NXT NXT2 Maintenance Ref MKT IM 010 C 18 10 2019 137 182 AC motor DC motor ...
Страница 139: ...Installer manual Fleck 3150 NXT NXT2 Maintenance Ref MKT IM 010 C 18 10 2019 139 182 DC motor ...
Страница 141: ...Installer manual Fleck 3150 NXT NXT2 Maintenance Ref MKT IM 010 C 18 10 2019 141 182 AC motor DC motor ...
Страница 144: ...Installer manual Fleck 3150 NXT NXT2 Maintenance 144 182 Ref MKT IM 010 C 18 10 2019 ...
Страница 148: ...Installer manual Fleck 3150 NXT NXT2 Maintenance 148 182 Ref MKT IM 010 C 18 10 2019 ...
Страница 182: ...www pentairaquaeurope com ...