Installer manual Evolio 255 740-760 - Maintenance
70 / 90
Ref. MKT-IM-037 / D - 25.10.2021
8.5.7.3
Cleaning the refill controller
1. Remove the softener and valve covers, see Covers removal (softener and valve) [
2. Using a Torx key, unscrew and extract the refill controller
(3)
.
3. Clean the refill controller
(3)
with a soft brush.
ð
Make sure the refill controller groove is perfectly clean.
4. Check for o-rings integrity.
5. Check for ball
(2)
integrity.
6. Clean the refill controller chamber
(1)
before reinserting the refill controller
(3)
and its ball
(2)
.
7. Reverse above procedure steps to rebuild.