Installer manual Evolio 255 740-760 - Maintenance
Ref. MKT-IM-037 / D - 25.10.2021
63 / 90
8.5.3
Brine tank and brine well cleaning
CAUTION
Do not pull on the cables.
Release the connectors from controller (1) by pressing on their locking clips.
1. Acceding from behind the softener, disconnect the controller
(1)
.
2. Remove the softener cover
(2)
.
3. Remove the brine tank cover
(5)
.
4. Remove the remaining salt from brine tank
(8)
.
5. Remove the brine well cover
(6)
.
6. Remove the remaining brine from brine well
(7)
.
7. Clean the brine tank
(8)
, the brine well
(7)
and the salt funnel
(3)
with water and sponges.
CAUTION
Do not lay down or flip over the softener to empty the brine tank.
8. Using a water vacuum, remove the cleaning waste and remaining water from brine tank (8)
and from brine well
(7)
.
9. Refit the brine well cover
(6)
.
10. Refit the brine tank cover
(5)
.
11. Refit the softener cover
(2)
.
12. Acceding from behind the softener, connect the controller (1), see Evolio 255 controller
13. Fill the brine tank
(8)
14. Close the cover
(4)
.
Содержание Evolio 255 10
Страница 1: ...www pentairaquaeurope com INSTALLER MANUAL EVOLIO 255 740 760 RESIDENTIAL ...
Страница 64: ...Installer manual Evolio 255 740 760 Maintenance 64 90 Ref MKT IM 037 D 25 10 2021 ...
Страница 72: ...Installer manual Evolio 255 740 760 Maintenance 72 90 Ref MKT IM 037 D 25 10 2021 ...
Страница 74: ...Installer manual Evolio 255 740 760 Maintenance 74 90 Ref MKT IM 037 D 25 10 2021 ...
Страница 78: ...Installer manual Evolio 255 740 760 Maintenance 78 90 Ref MKT IM 037 D 25 10 2021 ...