Installer manual Evolio 255 740-760 - Maintenance
Ref. MKT-IM-037 / D - 25.10.2021
77 / 90
8.5.7.8
Diassembling/assembling valve from/on tank
1. Remove the softener and valve covers, see Covers removal (softener and valve) [
2. Dismount the brine hose
(1)
.
3. Unscrew, counter-clockwise, the valve
(2)
from tank
(3)
.
4. Perform maintenance or change the valve
(2)
.
5. Lubricate the valve tank adapter and riser tube o-rings with approved lubricant only.
CAUTION
Do not use petroleum grease on gaskets when connecting bypass plumbing. Use only
100% silicone grease products when installing any plastic valve. Non-silicone grease
may cause plastic components to fail over time.
6. Spin the valve
(2)
onto the tank
(3)
, ensuring the threads are not cross-threaded.
7. Rotate the valve
(2)
clockwise and freely, without using force until it comes to a stop.
Info
This stop position is considered point zero.
8. Rotate the valve
(2)
clockwise from point zero to between ¼ turn and ½ turn.
CAUTION
Do NOT exceed 27 Nm of torque when installing the valve.
Exceeding this limit may damage the threads and cause failure.
9. Reverse steps
1
to
2
to rebuild.
Содержание Evolio 255 10
Страница 1: ...www pentairaquaeurope com INSTALLER MANUAL EVOLIO 255 740 760 RESIDENTIAL ...
Страница 64: ...Installer manual Evolio 255 740 760 Maintenance 64 90 Ref MKT IM 037 D 25 10 2021 ...
Страница 72: ...Installer manual Evolio 255 740 760 Maintenance 72 90 Ref MKT IM 037 D 25 10 2021 ...
Страница 74: ...Installer manual Evolio 255 740 760 Maintenance 74 90 Ref MKT IM 037 D 25 10 2021 ...
Страница 78: ...Installer manual Evolio 255 740 760 Maintenance 78 90 Ref MKT IM 037 D 25 10 2021 ...