background image

TABLE OF CONTENTS

MANUAL OVERVIEW ................................................................ 2
SAFETY INFORMATION ............................................................ 2
TYPICAL TOOLS AND FITTINGS REQUIRED ............................ 3
VALVE DIMENSIONS ................................................................ 3
VALVE LAYOUT ......................................................................... 4
SPECIFICATIONS ..................................................................... 4
EQUIPMENT INSTALLATION .................................................... 4
STARTUP - 360 ......................................................................... 6
STARTUP - 361 ......................................................................... 6
INSTALLATION CHECKLIST ..................................................... 6
CONTROL OPERATION AND LAYOUT ...................................... 7
INITIATING A CLEANING CYCLE .............................................. 7
FLOW DIAGRAMS ..................................................................... 8
VALVE ASSEMBLY - 360/361 .................................................... 9
TROUBLESHOOTING ................................................................ 10
FLOW PERFORMANCE DATA CHARTS .................................... 11

MANUAL OVERVIEW

How To Use This Manual

This manual is designed to guide the installer through the 

process of installing and starting the filter.
This manual is a reference and will not include every system 

installation situation. The person installing this equipment 

should have:

•  Knowledge in water filter installation
•  Basic plumbing skills

Icons That Appear In This Manual

WARNING:

 Failure to follow this instruction can result in 

personal injury or damage to the equipment.

NOTE: This will make the process easier if followed.

Inspection

Inspect the unit for damage or missing parts. 

SAFETY INFORMATION

Electrical (361 Only)

•  There are no user-serviceable parts in the AC adapter, 

motor, or controller. In the event of a failure, these should 

be replaced.

•  All electrical connections must be completed according to 

local codes.

•  Use only the power AC adapter that is supplied.
•  The power outlet must be grounded and always on.
•  To disconnect power, unplug the AC adapter from its 

power source.

•  Install an appropriate grounding strap across the inlet 

and outlet piping of the water system to ensure proper 

grounding is maintained.

Mechanical

•  Do not use petroleum-based lubricants such as 

petroleum jelly, oils, or hydrocarbon-based lubricants. 

Use only 100% silicone lubricants.

•  All plastic connections should be hand tightened. 

Plumber tape should be used on connections that do not 

use an O-ring seal. Do not use pliers or pipe wrenches.

•  All plumbing must be completed according to local codes.
•  Soldering of the plumbing should be done before 

connecting to the valve. Excessive heat will cause interior 

damage to the valve.

•  Observe local drain line requirements.
•  Do not use lead-based solder for sweat solder 

connections.

•  Do not support the weight of the system on the control 

valve fittings, plumbing, or the bypass.

•  It is not recommended to use sealants on the threads. 

Use plumber tape (PTFE) on all threads.

General

•  Observe all warnings that appear in this manual.
•  This system is not intended to be used for treating water 

that is microbiologically unsafe or of unknown quality 

without adequate disinfection before or after the system.

•  Keep the unit in the upright position. Do not turn on side,  

upside down, or drop. Turning the tank upside down will 

cause media to enter the valve.

•  Operating ambient temperature is between 34°F (1°C) 

and 120°F (49°C).

•  Operating water temperature is between 34°F (1°C) and 

100°F (38°C).

•  Working water pressure range is 20 to 125 psi  

(1.38 to 8.61 bar). 

•  Follow state and local codes for water testing. 
•  When filling media tank, do not open water valve 

completely. Fill tank slowly to prevent media from exiting 

the tank.

•  Always make modifications to house plumbing first. 

Connect to valve last.

•  Plastic parts and O-rings may be damaged by heat and 

solvents. When constructing plumbing connections, allow 

heated parts to cool and protect parts from solvents.

Location Selection

Location of a water treatment system is important. The 

following conditions are required:

•  Level platform or floor.
•  Constant electrical supply to operate the controller.
•  Total minimum pipe run to water heater of ten feet (three 

meters) to prevent backup of hot water into system.

•  Local drain or tub for discharge as close as possible.
•  Water line connections with shutoff or bypass valves.
•  Room to access equipment for maintenance.

CALIFORNIA PROPOSITION 65 WARNING

WARNING:

 This product contains chemicals known to the 

State of California to cause cancer or birth 

defects or other reproductive harm.

2 • 

AUTOTROL

 360/361 Filter Valves

Содержание AUTOTROL 360

Страница 1: ...AUTOTROL 360 MANUAL 361 SEMI AUTOMATIC FILTER VALVES SERVICE MANUAL waterpurification pentair com ...

Страница 2: ...ording to local codes Soldering of the plumbing should be done before connecting to the valve Excessive heat will cause interior damage to the valve Observe local drain line requirements Do not use lead based solder for sweat solder connections Do not support the weight of the system on the control valve fittings plumbing or the bypass It is not recommended to use sealants on the threads Use plumb...

Страница 3: ...m failures Temperature Extreme hot or cold temperatures may cause damage to the valve or controller Freezing temperatures will freeze the water in the valve This will cause physical damage to the internal parts as well as the plumbing Insects The controller and valve have been designed to keep all but the smallest insects out of the critical areas TYPICAL TOOLS AND FITTINGS REQUIRED Pipe Cutter Tu...

Страница 4: ... 20 gpm 30 76 lpm 3 4 1 9 cm 4 7 gpm 15 29 lpm EQUIPMENT INSTALLATION If you are also installing a water softener the softener should be installed downstream of this system Grounding the Plumbing It is important that the plumbing system be electrically grounded When a water treatment system is installed a nonmetallic bypass valve may interrupt the grounding To maintain continuity a grounding strap...

Страница 5: ...mpties into a drain below the level of the control valve form a 7 inch 18 cm loop at the far end of the line so that the bottom of the loop is level with the drain line connection This will provide an adequate siphon trap 4 Secure the discharge end of the drain line to prevent it from moving EQUIPMENT INSTALLATION continued Right Way Figure 6 Drain Line Connection NOTE Waste connections or drain o...

Страница 6: ...TUP 361 The system will now need to be placed into operation Please review INITIATING A CLEANING CYCLE on page 7 before attempting startup 1 With the supply water for the system still turned off position the bypass valve to the not in bypass normal operation position 2 Turn the control knob counter clockwise until the indicator arrow on the valve body is lined up with the Recycle icon to start a c...

Страница 7: ...wash flushing water through the filtration media in the tank 2 Turn the control knob counter clockwise until the indicator arrow is lined up with 2 Water will flow to drain 3 Turn the control knob counter clockwise to line up the indicator arrow with 0 to return the system back to normal operation Semi Automatic Cleaning Cycle 361 Valve 1 To start a cleaning cycle turn the control knob counter clo...

Страница 8: ...ater Backwash Media Tank Inlet Outlet 1 4 3 2 BACKWASH Drain Drain Control FAST RINSE Untreated Water Rinse Media Tank Inlet Outlet 4 3 Drain Control 1 2 Drain Valve No 1 Closed 2 Open 3 Closed 4 Closed Valve No 1 Open 2 Closed 3 Open 4 Closed Valve No 1 Closed 2 Open 3 Closed 4 Open 8 AUTOTROL 360 361 Filter Valves ...

Страница 9: ...rans 240V 1000814 EuropeWallTrans 240V 1000810 JapanWallTrans 100V 13 1 4002561 Kit Remote Regeneration 361 Filter 14 1 DrainLineFlowControl 4002459 Kit DLFC 4 0GPM NPT 360 Fltr 4002460 Kit DLFC 4 5GPM NPT 360 Fltr 4002461 Kit DLFC 5 0GPM NPT 360 Fltr 4002462 Kit DLFC 6 0GPM NPT 360 Fltr 4002463 Kit DLFC 7 0GPM NPT 360 Fltr 4002464 Kit DLFC 8 0GPM NPT 360 Fltr 4002465 Kit DLFC 9 0GPM NPT 360 Fltr ...

Страница 10: ...cs 361 control will not complete a cleaning cycle automatically AC adapter or motor not connected Connect power Debris is preventing camshaft from rotating Remove debris Defective motor Replace motor Backwashes or purges at excessively low or high rate No drain line flow control Install drain line flow control Restricted drain line Remove restriction TROUBLESHOOTING 10 AUTOTROL 360 361 Filter Valv...

Страница 11: ... 25 30 1 6 11 16 21 26 PRESSURE DROP IN PSI FLOW IN GPM Service Cv 5 43 0 5 10 15 20 25 30 35 1 6 11 16 21 PRESSURE DROP IN PSI FLOW IN GPM BW Cv 3 74 FLOW PERFORMANCE DATA CHARTS AUTOTROL 360 361 Filter Valves 11 ...

Страница 12: ...marks and logos are the property of their respective owners Because we are continuously improving our products and services Pentair reserves the right to change specifications without prior notice Pentair is an equal opportunity employer 4002447 REV B MR15 2013 Pentair Residential Filtration LLC All Rights Reserved For Autotrol Product Warranties visit Autotrol para las garantías de los productos ...

Отзывы: