CONTROL OPERATION AND LAYOUT

Simple Control Operation 

A simple three-step cycle control knob operates the cleaning 

cycle for continued operation.

Indicator Light (361 Only) 

A visual indicator shows when the system is in a cleaning cycle.

Easy Access Cover Removal 

No tools are required to remove cover to access valve assembly 

for service and repair.

Remove 

Cover

Indicator 

Light

(361 Only)

Control 

Knob

Figure 7 

INITIATING A CLEANING CYCLE

Under normal operation, the indicator arrow on the side of the 

valve body points to the Service icon   (361) or "0" (360) on the 

control knob.

Figure 8  361 Valve In Service

Figure 9 360 Valve In Service

Manual Cleaning Cycle (360 Valve)

1.  To start a cleaning cycle, turn the control knob counter-

clockwise until the indicator arrow is lined up with "1". The 

system will backwash, flushing water through the filtration 

media in the tank.

2.  Turn the control knob counter-clockwise until the indicator 

arrow is lined up with "2". Water will flow to drain.

3.  Turn the control knob counter-clockwise to line up the 

indicator arrow with "0" to return the system back to 

normal operation.

Semi-Automatic Cleaning Cycle (361 Valve)

1.  To start a cleaning cycle, turn the control knob counter-

clockwise until the indicator arrow is lined up with the 
Recycle icon 

2.  The system will automatically cycle through a backwash 

(20 minutes) and rinse (6 minutes) and return to normal 

operation.

NOTE:  The indicator light on the front valve cover will 

illuminate during regeneration. 

361 Remote Regeneration

An optional remote regeneration kit (P/N 4002561) is available 

for the 361 valve to enable fully automatic regeneration. When 

the kit is installed, a remote switch (such as a differential 

pressure switch) can be connected to the valve to control 

cleaning cycle initiation. 

AUTOTROL

 360/361 Filter Valves • 7

Содержание AUTOTROL 360

Страница 1: ...AUTOTROL 360 MANUAL 361 SEMI AUTOMATIC FILTER VALVES SERVICE MANUAL waterpurification pentair com ...

Страница 2: ...ording to local codes Soldering of the plumbing should be done before connecting to the valve Excessive heat will cause interior damage to the valve Observe local drain line requirements Do not use lead based solder for sweat solder connections Do not support the weight of the system on the control valve fittings plumbing or the bypass It is not recommended to use sealants on the threads Use plumb...

Страница 3: ...m failures Temperature Extreme hot or cold temperatures may cause damage to the valve or controller Freezing temperatures will freeze the water in the valve This will cause physical damage to the internal parts as well as the plumbing Insects The controller and valve have been designed to keep all but the smallest insects out of the critical areas TYPICAL TOOLS AND FITTINGS REQUIRED Pipe Cutter Tu...

Страница 4: ... 20 gpm 30 76 lpm 3 4 1 9 cm 4 7 gpm 15 29 lpm EQUIPMENT INSTALLATION If you are also installing a water softener the softener should be installed downstream of this system Grounding the Plumbing It is important that the plumbing system be electrically grounded When a water treatment system is installed a nonmetallic bypass valve may interrupt the grounding To maintain continuity a grounding strap...

Страница 5: ...mpties into a drain below the level of the control valve form a 7 inch 18 cm loop at the far end of the line so that the bottom of the loop is level with the drain line connection This will provide an adequate siphon trap 4 Secure the discharge end of the drain line to prevent it from moving EQUIPMENT INSTALLATION continued Right Way Figure 6 Drain Line Connection NOTE Waste connections or drain o...

Страница 6: ...TUP 361 The system will now need to be placed into operation Please review INITIATING A CLEANING CYCLE on page 7 before attempting startup 1 With the supply water for the system still turned off position the bypass valve to the not in bypass normal operation position 2 Turn the control knob counter clockwise until the indicator arrow on the valve body is lined up with the Recycle icon to start a c...

Страница 7: ...wash flushing water through the filtration media in the tank 2 Turn the control knob counter clockwise until the indicator arrow is lined up with 2 Water will flow to drain 3 Turn the control knob counter clockwise to line up the indicator arrow with 0 to return the system back to normal operation Semi Automatic Cleaning Cycle 361 Valve 1 To start a cleaning cycle turn the control knob counter clo...

Страница 8: ...ater Backwash Media Tank Inlet Outlet 1 4 3 2 BACKWASH Drain Drain Control FAST RINSE Untreated Water Rinse Media Tank Inlet Outlet 4 3 Drain Control 1 2 Drain Valve No 1 Closed 2 Open 3 Closed 4 Closed Valve No 1 Open 2 Closed 3 Open 4 Closed Valve No 1 Closed 2 Open 3 Closed 4 Open 8 AUTOTROL 360 361 Filter Valves ...

Страница 9: ...rans 240V 1000814 EuropeWallTrans 240V 1000810 JapanWallTrans 100V 13 1 4002561 Kit Remote Regeneration 361 Filter 14 1 DrainLineFlowControl 4002459 Kit DLFC 4 0GPM NPT 360 Fltr 4002460 Kit DLFC 4 5GPM NPT 360 Fltr 4002461 Kit DLFC 5 0GPM NPT 360 Fltr 4002462 Kit DLFC 6 0GPM NPT 360 Fltr 4002463 Kit DLFC 7 0GPM NPT 360 Fltr 4002464 Kit DLFC 8 0GPM NPT 360 Fltr 4002465 Kit DLFC 9 0GPM NPT 360 Fltr ...

Страница 10: ...cs 361 control will not complete a cleaning cycle automatically AC adapter or motor not connected Connect power Debris is preventing camshaft from rotating Remove debris Defective motor Replace motor Backwashes or purges at excessively low or high rate No drain line flow control Install drain line flow control Restricted drain line Remove restriction TROUBLESHOOTING 10 AUTOTROL 360 361 Filter Valv...

Страница 11: ... 25 30 1 6 11 16 21 26 PRESSURE DROP IN PSI FLOW IN GPM Service Cv 5 43 0 5 10 15 20 25 30 35 1 6 11 16 21 PRESSURE DROP IN PSI FLOW IN GPM BW Cv 3 74 FLOW PERFORMANCE DATA CHARTS AUTOTROL 360 361 Filter Valves 11 ...

Страница 12: ...marks and logos are the property of their respective owners Because we are continuously improving our products and services Pentair reserves the right to change specifications without prior notice Pentair is an equal opportunity employer 4002447 REV B MR15 2013 Pentair Residential Filtration LLC All Rights Reserved For Autotrol Product Warranties visit Autotrol para las garantías de los productos ...

Отзывы: