background image

30

GLOSSARY OF TERMS

A/C Contractor: A company licensed by the state and local au-
thorities to perform heating ventilation and air-conditioning in-
stallation or repair including pool heat pumps. Allow no others to
repair this unit.

Acetic: Describing pool/spa water that is aggressive in nature with
a Ph value below 7.6. Like acid, orange juice, vinegar etc.

Accumulator:  a containment housing in the Freon circuit that col-
lects liquid forms freon that does not evaporate after passing through
the evaporator coil, thus protecting the compressor from damage.

Air Blower: An electronic device that forces air under pressure
through the spa plumbing giving the spa a bubbling effect.

Air Inlet:  Used to create bubbling effects for the spa jets.  Water
passing through a vortex draws air into the plumbing without the
use of an electronic air blower. Usually controlled by some sort of
knob or lever to shut it on or off.

Alkaline: Describing pool/spa water that is the opposite of acetic
with a Ph value above 7.6. Base, like milk or chalk etc.

Anti Short Cycle Time Delay Device: Keeps the compressor from
being damaged due to the freon gas not being allowed to settle
between cycles, preventing liquid freon from entering the com-
pressor.  When the unit stops there will be a certain time delay
before the compressor will start again.

Automatic Chlorinator:  A device that feeds either tablet type or
liquid type chlorine concentration into the plumbing piping and
then delivered to the pool/spa water.

Authorized Factory Service:  An A/C Contractor factory trained
and under contract with the manufacturer to provide repair ser-
vice.

Back-Siphon:  In regards to pool filtering systems where the water
flow reverses through the system when the circulation pump shuts
off.  This is usually caused by the vacuum created by the water in
the filtering being above the pool level, or breach in the sealed
water plumbing, allowing air into the system. This condition is
sometimes referred to as a suction or vacuum leak.

Back Pressure:  The pressure created by the circulation pump be-
ing restricted by plumbing, filters, solar panels and other related
equipment.  Usually due to a dirty filter, measured by the pressure
gauge in the filter housing

Blanket:  A plastic cover several mills thick with trapped air bubbles,
cut to the same size as the pool and floats on top of the water to
provide insulation and prevent heat loss.  Some types collect small
amounts of heat from the sun and transfer it to the pool water.
Sometimes referred to as a solar blanket.

BTU:  British Thermal Units.  Measures heat output of a heat pump,
in Btu’s per hour.

Broadcast Type Sprinklers: Part of an irrigation system used to
water plants or grass where the water is sprayed into the air and
distributed directional.

Bypass:  Used in the water piping to allow the control of water
flow through the heater at a prescribed rate, thus the rest of the
water flow not needed is diverted through the bypass

Calcium Hardness: The amount of calcium and magnesium con-
tent in pool/spa water calculated by using a test kit for such pur-
poses.

Calcium Hypochlorite:  A form of chlorine in a powder form and
rarely  in a tablet form used to sanitize pool/spa water.  Calcium is
a major component and by-product.

Cartridge Filter:  A pool/ spa water filter that is made of pleated
paper and nylon. Usually round with plastic base and top, placed
into a tank that the water is pumped through trapping debris and
dirt.  Usually removed and cleaned with a high pressure garden
hose.

Check Valve: A P.V.C. fitting used on the water piping to prevent
reverse flow through the system and insure proper water direction.
Sometimes used to create back pressure and slow the water veloc-
ity.

Chemical Values: The numerical reading you get by using a pool/
spa water test kit to calculate levels of pool chemicals and miner-
als in the pool water at any given time.

Chemical Damage: Any damage or corrosion from pool chemicals
or any other chemicals used around the heat pump or pool.  Usu-
ally concentrated chlorine or acetic water corroding the copper
piping or the heat exchanger or other equipment.

Chemical Resistant Check Valve:  A check valve placed between
the heater and a chlorinator to prevent the migration of concen-
trated chlorine into the heater.

Chlorinator:  A device that is used to feed chlorine to the pool/spa
through the filtering system.  Water is pumped through a contain-
ment holding the chlorine. This makes a solution that is then fed to
the pool or spa.

Chlorinator Placement:  (Illustrated in this owners manual), show-
ing the  proper location and placement of chlorinating devices in
order to prevent chemical damage to the heater.

Chlorine:  A common pool/spa water sanitizer available in several
different forms of powder, solid tablets, liquid or gas.

Chlorine Tablets:  A common form of chlorine that is solid in na-
ture used in a chlorinator that is eroded by water rushing over these
tablets, making a solution to be slowly fed to the pool water.

Содержание 400, 600, 800, 1000, 230

Страница 1: ...x Plus HP 800 XLS800 MiniMax Plus HP 1000 XLS1000 MiniMax Plus HP 230 CP12 WARNING FOR YOUR SAFETY READ BEFORE OPERATING Warning If you do not follow these instructions exactly a fire or explosion may...

Страница 2: ...Pump Plumbing Bypass c Mandatory Chlorinator Loop Check Valve 5 CHEMICAL CHLORINATOR APPLICATION USE a Water Quality and Testing Values a Heat Exchanger Protection Sacrificial Water Fittings b Chemica...

Страница 3: ...cost can be more for a gas heater consid ering the fact that a gas heater starts to lose efficiency as it gets older The heat pump s sealed system needs far less attention Electric Oil Heat Pump 0 32...

Страница 4: ...Proof Fiberglass Top Non Fading Quiet High Volume Fan With Vinyl Coated Guard Product Name Plate Chemical Warning Label Automatic Diagnostics With L E D Display Electronic Thermostat Optional Pool Spa...

Страница 5: ...Block of Foam to Prevent Heat Loss Corrosion DESIGN ADVANTAGES Internal Automatic Bypass Free Flow 2 Plumbing Automatically adjusts the water flow Lowest water flow restriction available Internal Aut...

Страница 6: ...Ac tual pool temperatures are determined by your installer when the unit is sized to your specifications The lowest setting on the thermostat is around 60 degrees F To disable the heater turn the the...

Страница 7: ...reset temperature When this light is off the heater and the low and high pressure lights will stay off LOW PRESS OK Green The green low pressure indicator light is designed to let you know that the lo...

Страница 8: ...POOL SERVICE CO If you have a regular pool service on a weekly basis make sure your owners manual available for them to inspect You may request that one be sent to them by calling the factory service...

Страница 9: ...e compressor pumps and compresses re frigerant gas When refrigerant gas is com pressed it intensifies the heat before it is release to the pool water This compressed hot gas is pumped through the heat...

Страница 10: ...timer manufacturers in structions to prevent electrical shock Consult your dealer first INITIAL HEAT UP TIME HEATERS You should start by letting the circulation pump run 24 hours a day until the pool...

Страница 11: ...ill come on each day when the circulation pump starts then it will bring the pool up to that set temperature The pool will lose some heat overnight but will come back up to temperature with minimal de...

Страница 12: ...imply the loss of heat due to the cooler outside air moving across the waters surface Heat moves from hot to cold only so the warmer pool heat transfers to the moving cooler air Windy conditions will...

Страница 13: ...r usage as well 13 SPAS HEATING TIPS It is strongly suggested that you use a cover during the initial heat up time This will save time as well as elec trical costs When heating a spa make sure that th...

Страница 14: ...allation area should be kept trimmed away to the proper clearances shown here Plants too close to the heater will restrict the air flow into the unit from the side as well as air flow through the top...

Страница 15: ...ts of rain water from running through the unit you may need to install a gutter and down spout when the roof has a sharp pitch IMPORTANT Do not allow roof run off water to rush through the unit Do not...

Страница 16: ...Proper water flow is critical to the heaters performance and longevity The maintenance of your filtering sys tem is directly related to the proper operation of the heat pump See pages 8 for other inf...

Страница 17: ...s plugged in it may cause the pump to loose prime due to the air in the hose You may also need to restrict the main drain suction port to gain more vacuum to the vacuum hose and head This will lower t...

Страница 18: ...a 2 inch p v c glue fitting The pipe is left plain so you can adapt to your needs Use p v c cleaner to prime the fitting and pipe Use a quality medium body p v c glue FOR PUMPS UP TO 2 H P OR 90 G P M...

Страница 19: ...the heater see shut down procedures Some larger water pumps may be restricted if the pipe size is not adequate therefore reducing its overall flow rate When determining if you need an excessive bypas...

Страница 20: ...ttings to protect the very expensive cu pronickel alloy heat exchanger These fittings may develop a leak if the pool water balance gets very acetic or very over chlorinated If there were no sacrificia...

Страница 21: ...rate Do not add shock treat ment or chlorine tablets in the skimmer Read and follow the chemical manufacturers directions when adding chemicals unless they conflict with this book let Contact your de...

Страница 22: ...ring seals in the pump lid filter and chlorinator are in good condition and are lubricated with silicone grease If your filter repeatedly has excessive air inside it when you open air the bleed valve...

Страница 23: ...l allow a concentrated solution of chlorine to pass through the heat exchanger causing damage 7 Do not place any chemicals in the pump lint trap cav ity or filter Make sure the lint trap basket is pla...

Страница 24: ...ions that we feel will prolong the life of the heat exchanger used for a spa heater 1 Test the water frequently to prevent drastic fluctuations in pH and sanitizer levels especially after usage Keep t...

Страница 25: ...switch but keep the water pump running LONG TERM FREEZE PROTECTION DRAIN VALVE INSTALLATION If you live in a climate that has a seasonal swim season due to winter you should follow these long term fre...

Страница 26: ...n back through the outer air coil The fan is obstructed low air flow Large amounts of roof run off water restricting fan blade rotation Sprinklers spraying on the outer air coil during cooler temperat...

Страница 27: ...ll plumbing valves Repair suction air leaks grease pump lid o ring Use a pool cover Place a wind break around pool Set pool pump timer longer Call your dealer for advise Call the factory for advice Fo...

Страница 28: ...is about 3 feet Line side of the main contactor will be on the top The model number is located on a silver label on the front of the unit UNIT IDENTIFICATION IN SOME CASES WE HAVE SPECIFIED BETTER THA...

Страница 29: ...t is not covered under the warranty agreement The pool owner is responsible for the correct adjustment and maintenance of the filtering system 4 If the dealer is unavailable to help you the factory se...

Страница 30: ...nt heat loss Some types collect small amounts of heat from the sun and transfer it to the pool water Sometimes referred to as a solar blanket BTU British Thermal Units Measures heat output of a heat p...

Страница 31: ...ll shut the compressor off but allow the fan to run until the air temperature increases Down Line A reference that pertains to chlorinator placement and chemical application meaning to introduce such...

Страница 32: ...nside the cabinet of the unit Lint Trap Basket A strainer type basket that collects debris and prevents such from being trapped in other equipment including the heat exchanger Liquid Chlorine Chlorine...

Страница 33: ...tion pump Filter elements are some times placed in this tank so when the pump suctions water through them it cleans the water This tank is fed pool water through plumb ing piped from the pool by gravi...

Страница 34: ...34 This page is blank...

Страница 35: ...35 This page is blank...

Страница 36: ...Manufactured by 2001 HydroTemp Manufacturing Co Inc 941 768 1555 www warmpool com Heat Pumps...