HEAT EXCHANGER
The compressed hot refrigerant releases it's heat to the
pool water inside the heat exchanger. The exchanger is
a tube within a tube construction, water passing through

the  inner  tube,  hot  gas  passing
through the outer tube.  The refriger-
ant is transformed into a liquid state

as it exits the heat exchanger. There-
fore it is also referred to

as a condenser coil.   (Heat & Cool Models,
process is reverse). The exchanger is en-
cased inside a block of closed cell foam to
prevent heat loss and corrosion.

See the cross section.

Turning up the thermostat will start the
unit running. When the pool water has
been heated to the thermostat setting, the
unit will shut off.  When the pool water
temperature loses one to two degrees,
the thermostat will activate the unit.
There are no temperature graduate num-
bers printed on the thermostat face.   To

obtain an exact temperature, turn the t-stat
all the way up and then place a pool type
thermometer in the pool water itself.  Once
the water has reached your target tempera-
ture on the thermometer, turn the thermo-
stat knob backwards until the heater just
shuts off.  Make a mental note of knob in-
dicator. Therefore your thermostat will be
set at the thermometer reading.

THERMOSTAT CONTROL & SETTINGS

FAN-AIR CIRCULATION
Once the t-stat is activated the
fan will begin to turn.  To ab-
sorb heat energy, the fan circu-
lates warmer air through the
evaporator coil at about 4000
cubic feet per minute.  The fan
runs independently from the
compressor.  The compressor
will start within 5 to 7 minutes
after the fan.

COMPRESSOR
Once the fan is running, the compressor will start  5 to
7 minutes later, it's controlled by a time delay device.
The compressor pumps and compresses re-
frigerant gas.  When refrigerant gas is com-
pressed it intensifies the heat before it is
release to the pool water.  This compressed
hot  gas is pumped through the heat ex-
changer where it delivers heat to the pool
water passing through the same heat ex-
changer.

EVAPORATOR AIR COIL

The fan circulates the warmer out-
side air through the evaporator air
coil to collect any available heat.  The
cooler Freon™ absorbs this heat
causing it to evaporate into a gas.
Therefore the compressor can com-
press the gas  to maximize the gain
heat from the air. The fan discharges
cooler air when the compressor is running. Process is
reversed in Heat & Cool models while in cooling mode.

Warm Water

In

Cool Water

Out

Warm

Air

In

Cool Air Out

Compressor

Air Coil

Heat

Exchanger

Plumbing Bypass

Manifold

Freon™

Lines

Hot Gas

SYSTEM OVERVIEW
The heat pump system
uses 410-A refrigerant to
transfer the heat from the
outside air to the pool
water.

OPERATIONAL SEQUENCE

THERMOSTAT CONTROL & SETTINGS FOR
HEAT & COOL MODELS

For heating modes on these models,
make sure toggle is selected to heat and
follow the previous instructions above.

For cooling mode make sure toggle is
selected to cool.  Turning down the ther-

mostat counter clockwise will start the
unit running.  When the pool water has

been cooled to the thermostat setting,
the unit will shut off.  When the pool

water temperature rises one to two degrees, the thermo-
stat will activate the unit. There are no temperature gradu-
ate numbers printed on the thermostat face.   To obtain an
exact temperature, turn the t-stat all the way down  and
then place a pool type thermometer in the pool water it-
self.  Once the water has reached your target temperature
on the thermometer, turn the thermostat knob forwards
until the heater just shuts off.  Therefore your thermostat
will be set at the thermometer reading.

Heat      Cool

Содержание 400, 600, 800, 1000, 230

Страница 1: ...x Plus HP 800 XLS800 MiniMax Plus HP 1000 XLS1000 MiniMax Plus HP 230 CP12 WARNING FOR YOUR SAFETY READ BEFORE OPERATING Warning If you do not follow these instructions exactly a fire or explosion may...

Страница 2: ...Pump Plumbing Bypass c Mandatory Chlorinator Loop Check Valve 5 CHEMICAL CHLORINATOR APPLICATION USE a Water Quality and Testing Values a Heat Exchanger Protection Sacrificial Water Fittings b Chemica...

Страница 3: ...cost can be more for a gas heater consid ering the fact that a gas heater starts to lose efficiency as it gets older The heat pump s sealed system needs far less attention Electric Oil Heat Pump 0 32...

Страница 4: ...Proof Fiberglass Top Non Fading Quiet High Volume Fan With Vinyl Coated Guard Product Name Plate Chemical Warning Label Automatic Diagnostics With L E D Display Electronic Thermostat Optional Pool Spa...

Страница 5: ...Block of Foam to Prevent Heat Loss Corrosion DESIGN ADVANTAGES Internal Automatic Bypass Free Flow 2 Plumbing Automatically adjusts the water flow Lowest water flow restriction available Internal Aut...

Страница 6: ...Ac tual pool temperatures are determined by your installer when the unit is sized to your specifications The lowest setting on the thermostat is around 60 degrees F To disable the heater turn the the...

Страница 7: ...reset temperature When this light is off the heater and the low and high pressure lights will stay off LOW PRESS OK Green The green low pressure indicator light is designed to let you know that the lo...

Страница 8: ...POOL SERVICE CO If you have a regular pool service on a weekly basis make sure your owners manual available for them to inspect You may request that one be sent to them by calling the factory service...

Страница 9: ...e compressor pumps and compresses re frigerant gas When refrigerant gas is com pressed it intensifies the heat before it is release to the pool water This compressed hot gas is pumped through the heat...

Страница 10: ...timer manufacturers in structions to prevent electrical shock Consult your dealer first INITIAL HEAT UP TIME HEATERS You should start by letting the circulation pump run 24 hours a day until the pool...

Страница 11: ...ill come on each day when the circulation pump starts then it will bring the pool up to that set temperature The pool will lose some heat overnight but will come back up to temperature with minimal de...

Страница 12: ...imply the loss of heat due to the cooler outside air moving across the waters surface Heat moves from hot to cold only so the warmer pool heat transfers to the moving cooler air Windy conditions will...

Страница 13: ...r usage as well 13 SPAS HEATING TIPS It is strongly suggested that you use a cover during the initial heat up time This will save time as well as elec trical costs When heating a spa make sure that th...

Страница 14: ...allation area should be kept trimmed away to the proper clearances shown here Plants too close to the heater will restrict the air flow into the unit from the side as well as air flow through the top...

Страница 15: ...ts of rain water from running through the unit you may need to install a gutter and down spout when the roof has a sharp pitch IMPORTANT Do not allow roof run off water to rush through the unit Do not...

Страница 16: ...Proper water flow is critical to the heaters performance and longevity The maintenance of your filtering sys tem is directly related to the proper operation of the heat pump See pages 8 for other inf...

Страница 17: ...s plugged in it may cause the pump to loose prime due to the air in the hose You may also need to restrict the main drain suction port to gain more vacuum to the vacuum hose and head This will lower t...

Страница 18: ...a 2 inch p v c glue fitting The pipe is left plain so you can adapt to your needs Use p v c cleaner to prime the fitting and pipe Use a quality medium body p v c glue FOR PUMPS UP TO 2 H P OR 90 G P M...

Страница 19: ...the heater see shut down procedures Some larger water pumps may be restricted if the pipe size is not adequate therefore reducing its overall flow rate When determining if you need an excessive bypas...

Страница 20: ...ttings to protect the very expensive cu pronickel alloy heat exchanger These fittings may develop a leak if the pool water balance gets very acetic or very over chlorinated If there were no sacrificia...

Страница 21: ...rate Do not add shock treat ment or chlorine tablets in the skimmer Read and follow the chemical manufacturers directions when adding chemicals unless they conflict with this book let Contact your de...

Страница 22: ...ring seals in the pump lid filter and chlorinator are in good condition and are lubricated with silicone grease If your filter repeatedly has excessive air inside it when you open air the bleed valve...

Страница 23: ...l allow a concentrated solution of chlorine to pass through the heat exchanger causing damage 7 Do not place any chemicals in the pump lint trap cav ity or filter Make sure the lint trap basket is pla...

Страница 24: ...ions that we feel will prolong the life of the heat exchanger used for a spa heater 1 Test the water frequently to prevent drastic fluctuations in pH and sanitizer levels especially after usage Keep t...

Страница 25: ...switch but keep the water pump running LONG TERM FREEZE PROTECTION DRAIN VALVE INSTALLATION If you live in a climate that has a seasonal swim season due to winter you should follow these long term fre...

Страница 26: ...n back through the outer air coil The fan is obstructed low air flow Large amounts of roof run off water restricting fan blade rotation Sprinklers spraying on the outer air coil during cooler temperat...

Страница 27: ...ll plumbing valves Repair suction air leaks grease pump lid o ring Use a pool cover Place a wind break around pool Set pool pump timer longer Call your dealer for advise Call the factory for advice Fo...

Страница 28: ...is about 3 feet Line side of the main contactor will be on the top The model number is located on a silver label on the front of the unit UNIT IDENTIFICATION IN SOME CASES WE HAVE SPECIFIED BETTER THA...

Страница 29: ...t is not covered under the warranty agreement The pool owner is responsible for the correct adjustment and maintenance of the filtering system 4 If the dealer is unavailable to help you the factory se...

Страница 30: ...nt heat loss Some types collect small amounts of heat from the sun and transfer it to the pool water Sometimes referred to as a solar blanket BTU British Thermal Units Measures heat output of a heat p...

Страница 31: ...ll shut the compressor off but allow the fan to run until the air temperature increases Down Line A reference that pertains to chlorinator placement and chemical application meaning to introduce such...

Страница 32: ...nside the cabinet of the unit Lint Trap Basket A strainer type basket that collects debris and prevents such from being trapped in other equipment including the heat exchanger Liquid Chlorine Chlorine...

Страница 33: ...tion pump Filter elements are some times placed in this tank so when the pump suctions water through them it cleans the water This tank is fed pool water through plumb ing piped from the pool by gravi...

Страница 34: ...34 This page is blank...

Страница 35: ...35 This page is blank...

Страница 36: ...Manufactured by 2001 HydroTemp Manufacturing Co Inc 941 768 1555 www warmpool com Heat Pumps...

Отзывы: