background image

32

Floating Thermometer:  A thermometer that floats on the water
surface with the main sensing bulb in the water.  Indicates the ac-
tual pool or spa temperature it’s floating in.  A tie on type will
work the same.

Flow Control Valve: A valve or check valve that controls water
flow either automatically or manually.
Freon™: Trade name for a type of refrigerant.  The heat transfer
medium used to transfer the generated heat to the pool water, in
the vapor compression cycle of the heat pump system.  Changing
from a gas to a liquid state in cycles.

Full Prime:  A reference used to describe a water pump running
normally without air entering into the system, running at full ca-
pacity.

Gas Chlorine:  Chlorine in a pure state, gas.

G.P.M. :  Gallons per minute, used to measure flow rate

Heat & Cool:  The unit, the heater, the appliance referenced in this
manual.  A reverse cycle unit capable of both heating and cooling.

Heat Exchanger:  A manifold where the compressed hot freon gas
transfers its heat to the pool water.  A tube within a tube.  Hot freon
gas passing through one tube and water passing through the other
tube, bent in a coiled fashion.  Made from a cupronickel metal
alloy.

Heat Loss: The act of the pool losing heat due to certain conditions
such as weather, wind, evaporation, radiance, convection etc.

Heat Pump: The unit, the heater, the appliance referenced in this
manual.

Hydro-Therapy Jets: Used in spas to create high pressure water
flow with air turbulence.  Water is forced through a restriction that
creates a vortex that draws air into the water flow thus increasing
velocity.  This air flow is usually regulated by a manual control.

Icing Up: Ice forming on the evaporator coil.

In Line Type Chlorinator:  A chlorinating device that is mounted
directly on the piping, that has an internal manifold within the
plumbing, used to allow water flow through the containment, where
a solid tablet type chlorine is held.  This type requires no water
tubing in and out of the containment.

Injection:  In regard to feeding pool chemicals into the water flow
in whatever fashion.

Installer: Same as dealer, person or company where the unit was
purchased.

Internal Adjustments:  Any part or component inside the cabinet of
the unit.

Lint Trap Basket: A strainer type basket that collects debris and
prevents such from being trapped in other equipment, including
the heat exchanger.

Liquid Chlorine: Chlorine in a liquid form, (sodium hypochlorite).

Long Term Freeze:  When the outside air temperature drops below
36 degrees as part of a seasonal weather change lasting for an ex-
tended period of time.

Marcite:  A white plaster type pool wall and surface finishing ma-
terial made of white Portland cement and marble dust.

Migrate:  Referring to concentrated chlorine moving through the
filter system plumbing with or without the water flowing.

Motorized Plumbing Valves:  Valves that are driven by low volt-
age motors mounted on top of such a valve.  Usually used to change
from pool to spa mode via a control switch or device without hav-
ing to go to the filter system and turn these valves manually.

Muriatic Acid:  A liquid acid that is used to lower the Ph of pool
water.  Handle with extreme caution.  (Use a dry powder acid for

spas.)

Normal Operation:  When the heat pump is running as intended by
the manufacturer.

Nozzle Attachment:  A device attached to the end of a garden hose,
that increases pressure and controls direction.

On/Off Switch:  Located on the unit next to the thermostat dial use
to shut the unit off and on, so you do not have to move the thermo-
stat or shut off the circuit breaker to control the unit.
O-Ring:  A round rubber gasket that is used for sealing removable
access lids to pool filtering equipment and other related items.

Ph:  A term used when determining the alkalinity or acetic nature
of water.

Pool/Spa Combination:  When you have a pool and spa together,
where the two body’s of water are connected by a spill-over or
other plumbing means.

PPM: Parts per million.  Use as a term to tell you how much of a
certain chemical ratio is in the water.

Pressure Switch: A device inside the heater, that senses water pres-
sure and keeps the unit from running when there is little or no
water flow going through it.

Radiant Heat Loss:  When the water loses heat through the walls
and floor of the pool shell.

Return: The term used to indicate water flow direction back to the
pool, after it passes through the filtering system.  There are ori-
fices in the pool called return outlets.

Run Dry:  When any pool equipment is running without water,
usually causing some sort of damage.

Содержание 400, 600, 800, 1000, 230

Страница 1: ...x Plus HP 800 XLS800 MiniMax Plus HP 1000 XLS1000 MiniMax Plus HP 230 CP12 WARNING FOR YOUR SAFETY READ BEFORE OPERATING Warning If you do not follow these instructions exactly a fire or explosion may...

Страница 2: ...Pump Plumbing Bypass c Mandatory Chlorinator Loop Check Valve 5 CHEMICAL CHLORINATOR APPLICATION USE a Water Quality and Testing Values a Heat Exchanger Protection Sacrificial Water Fittings b Chemica...

Страница 3: ...cost can be more for a gas heater consid ering the fact that a gas heater starts to lose efficiency as it gets older The heat pump s sealed system needs far less attention Electric Oil Heat Pump 0 32...

Страница 4: ...Proof Fiberglass Top Non Fading Quiet High Volume Fan With Vinyl Coated Guard Product Name Plate Chemical Warning Label Automatic Diagnostics With L E D Display Electronic Thermostat Optional Pool Spa...

Страница 5: ...Block of Foam to Prevent Heat Loss Corrosion DESIGN ADVANTAGES Internal Automatic Bypass Free Flow 2 Plumbing Automatically adjusts the water flow Lowest water flow restriction available Internal Aut...

Страница 6: ...Ac tual pool temperatures are determined by your installer when the unit is sized to your specifications The lowest setting on the thermostat is around 60 degrees F To disable the heater turn the the...

Страница 7: ...reset temperature When this light is off the heater and the low and high pressure lights will stay off LOW PRESS OK Green The green low pressure indicator light is designed to let you know that the lo...

Страница 8: ...POOL SERVICE CO If you have a regular pool service on a weekly basis make sure your owners manual available for them to inspect You may request that one be sent to them by calling the factory service...

Страница 9: ...e compressor pumps and compresses re frigerant gas When refrigerant gas is com pressed it intensifies the heat before it is release to the pool water This compressed hot gas is pumped through the heat...

Страница 10: ...timer manufacturers in structions to prevent electrical shock Consult your dealer first INITIAL HEAT UP TIME HEATERS You should start by letting the circulation pump run 24 hours a day until the pool...

Страница 11: ...ill come on each day when the circulation pump starts then it will bring the pool up to that set temperature The pool will lose some heat overnight but will come back up to temperature with minimal de...

Страница 12: ...imply the loss of heat due to the cooler outside air moving across the waters surface Heat moves from hot to cold only so the warmer pool heat transfers to the moving cooler air Windy conditions will...

Страница 13: ...r usage as well 13 SPAS HEATING TIPS It is strongly suggested that you use a cover during the initial heat up time This will save time as well as elec trical costs When heating a spa make sure that th...

Страница 14: ...allation area should be kept trimmed away to the proper clearances shown here Plants too close to the heater will restrict the air flow into the unit from the side as well as air flow through the top...

Страница 15: ...ts of rain water from running through the unit you may need to install a gutter and down spout when the roof has a sharp pitch IMPORTANT Do not allow roof run off water to rush through the unit Do not...

Страница 16: ...Proper water flow is critical to the heaters performance and longevity The maintenance of your filtering sys tem is directly related to the proper operation of the heat pump See pages 8 for other inf...

Страница 17: ...s plugged in it may cause the pump to loose prime due to the air in the hose You may also need to restrict the main drain suction port to gain more vacuum to the vacuum hose and head This will lower t...

Страница 18: ...a 2 inch p v c glue fitting The pipe is left plain so you can adapt to your needs Use p v c cleaner to prime the fitting and pipe Use a quality medium body p v c glue FOR PUMPS UP TO 2 H P OR 90 G P M...

Страница 19: ...the heater see shut down procedures Some larger water pumps may be restricted if the pipe size is not adequate therefore reducing its overall flow rate When determining if you need an excessive bypas...

Страница 20: ...ttings to protect the very expensive cu pronickel alloy heat exchanger These fittings may develop a leak if the pool water balance gets very acetic or very over chlorinated If there were no sacrificia...

Страница 21: ...rate Do not add shock treat ment or chlorine tablets in the skimmer Read and follow the chemical manufacturers directions when adding chemicals unless they conflict with this book let Contact your de...

Страница 22: ...ring seals in the pump lid filter and chlorinator are in good condition and are lubricated with silicone grease If your filter repeatedly has excessive air inside it when you open air the bleed valve...

Страница 23: ...l allow a concentrated solution of chlorine to pass through the heat exchanger causing damage 7 Do not place any chemicals in the pump lint trap cav ity or filter Make sure the lint trap basket is pla...

Страница 24: ...ions that we feel will prolong the life of the heat exchanger used for a spa heater 1 Test the water frequently to prevent drastic fluctuations in pH and sanitizer levels especially after usage Keep t...

Страница 25: ...switch but keep the water pump running LONG TERM FREEZE PROTECTION DRAIN VALVE INSTALLATION If you live in a climate that has a seasonal swim season due to winter you should follow these long term fre...

Страница 26: ...n back through the outer air coil The fan is obstructed low air flow Large amounts of roof run off water restricting fan blade rotation Sprinklers spraying on the outer air coil during cooler temperat...

Страница 27: ...ll plumbing valves Repair suction air leaks grease pump lid o ring Use a pool cover Place a wind break around pool Set pool pump timer longer Call your dealer for advise Call the factory for advice Fo...

Страница 28: ...is about 3 feet Line side of the main contactor will be on the top The model number is located on a silver label on the front of the unit UNIT IDENTIFICATION IN SOME CASES WE HAVE SPECIFIED BETTER THA...

Страница 29: ...t is not covered under the warranty agreement The pool owner is responsible for the correct adjustment and maintenance of the filtering system 4 If the dealer is unavailable to help you the factory se...

Страница 30: ...nt heat loss Some types collect small amounts of heat from the sun and transfer it to the pool water Sometimes referred to as a solar blanket BTU British Thermal Units Measures heat output of a heat p...

Страница 31: ...ll shut the compressor off but allow the fan to run until the air temperature increases Down Line A reference that pertains to chlorinator placement and chemical application meaning to introduce such...

Страница 32: ...nside the cabinet of the unit Lint Trap Basket A strainer type basket that collects debris and prevents such from being trapped in other equipment including the heat exchanger Liquid Chlorine Chlorine...

Страница 33: ...tion pump Filter elements are some times placed in this tank so when the pump suctions water through them it cleans the water This tank is fed pool water through plumb ing piped from the pool by gravi...

Страница 34: ...34 This page is blank...

Страница 35: ...35 This page is blank...

Страница 36: ...Manufactured by 2001 HydroTemp Manufacturing Co Inc 941 768 1555 www warmpool com Heat Pumps...

Отзывы: