background image

GB

For:
VIH GB 260 S
VIH GB 310 S

Instructions for installation

uniSTOR

For the installer

Immersion Heater

Содержание uniSTOR VIH GB 260 S Instructions for and use

Страница 1: ...GB For VIH GB 260 S VIH GB 310 S Instructions for installation uniSTOR For the installer Immersion Heater ...

Страница 2: ...n 3 1 2 Safety instructions and symbols 3 2 Safety instructions 3 2 1 Note to Installers 3 3 Mounting of the accessory immersion heater 4 3 1 Preparation of the cylinder 4 3 2 Mounting of the immersion heater 4 4 Commissioning Care and Maintenance 7 4 1 Commissioning 7 4 2 Care and Maintenance 7 5 Guarantee 7 Contents ...

Страница 3: ...lways use new seals and O rings when parts are replaced Always carry out functional checks after any service work Always check earth continuity polarity and resistance to earth with a multimeter after any service work and after replacing any electrical component Danger Electrocution touching live parts can be fatal Protect the switch box from water Before working on the appliance turn off the powe...

Страница 4: ...he cylinder to below the level of the flanged socket for the 2nd immersion heater Strip the round sticker situated in the upper area of the cylinder to cover the flange socket Cut out the Styrofoam insulation along the perforation marked in the cylinder cover see figure 3 1 Remove the brass plug and if necessary the flat seal of the flange a c b d Fig 3 1 Preparation of the cylinder 3 2 Mounting o...

Страница 5: ...rewdriver 7 Fig 3 4 Fixing the immersion heater First push the longer thermostat sensor 8 into the sensor pipe 9 Then push the shorter sensor 10 for the thermal cut out into the sensor pipe 8 9 10 Fig 3 5 Mounting of the sensor Now connect the heater wiring see figure 3 6 N L Fig 3 6 Electrical connections Mounting of the accessory immersion heater 3 ...

Страница 6: ...desired temperature by means of the ther mostat 14 with a screwdriver The thermostat is adjustable from 30 C to 65 C Note All wiring must be carried out in accordance with BS 7671 Requirements for electrical installations IEE Wiring Regulations 16th edi tion by a qualified installer Caution The immersion heater must be earthed The immersion heater is equipped with a safety over heat cut off device...

Страница 7: ...e set by the installer while commissioning the uniSTOR normally a setting of 60 C is adequate 4 2 Care and Maintenance The casing of the immersion heater may be cleaned with a damp cloth and a little soap Do not use any abrasive or solvent material which could damage the case or fittings 5 Guarantee The immersion heater carries a Vaillant 2 year guarantee against faulty materials or manufacture Co...

Страница 8: ...01 GB 11 2005 Subject to alteration Printed in Germany Head Office Vaillant Ltd Service Solutions 0870 6060 777 Vaillant House Trident Close Medway City Estate Rochester Kent ME2 4EZ Technical Advice 01634 292392 ...