8

upright. Do not completely fill;
leave oil about 1 inch below
plug hole. Use only high grade
transformer oil or regular
Hydromatic submersible oil in
this chamber. Replace plug;
use Permatex on threads.
Install air valve in top plug
opening of motor housing and
charge housing with about 
10 psi of air. Be sure air is 
dry. Do not use air line where
water may be trapped in 
the line. Submerge complete 
unit under water and check 
for leaks.

14.Refill motor chamber with oil. 

Use high grade transformer 
oil or Hydromatic special 
submersible oil. Fill chamber
until oil covers top of windings.
Leave air space in top for
expansion. Use Permatex on
plug threads.

Replacing Seals and Bearings:

1. Drain all oil from motor chamber

and seal chamber as described.

2. Remove motor housing as 

described.

3. Remove bolts that hold seal

chamber to pump housing. Use
back-off screws to break loose.
With hardwood block, tap end
of impeller to loosen from
shaft. When free, remove
impeller from shaft.

4. Lift rotating assembly (rotor,

shaft and impeller) from pump
case and place horizontally 
on bench.

5. Remove screw and washer

from end of shaft and then
screw socket head bolt back
into shaft. Using a screwdriver
on opposite sides behind
impeller, apply force then tap

on end of socket bolt to break
impeller loose from taper
shaft.

6. Remove key and pry on each

side of shoulder of shaft sleeve
to remove. Seal should come
off with sleeve. If sleeve is not
free, leave in place and push
off when seal plate is removed.

7. To remove seal plate take out

socket head flat screws and
using screws in back-off 
holes, pry plate loose. This will
also force seal off if not
already removed. 

8. Remove snap ring that holds

upper seal. Pull seal if it is free.
If not free, it can be forced off
when shaft is removed.

9. Remove 4 bolts that hold bearing

housing in place (on units built
prior to 2/14/78).  Set assembly
in upright position and bump
end of shaft on hardwood
block. This will push the bearing
from the housing and will
force upper seal from shaft.

10.Use bearing puller to remove 

bearings. Replace with new 
bearings. Press only on inner

face of bearing when replacing.
Pressing on outer face can
damage the bearing. Bearings
are standard size that can be
obtained from any bearing supply
house or can be obtained from
Hydromatic factory.

11.

Important:

Do not use any of

the old seal parts. Replace with
all new seals.

12.Thoroughly clean all castings

before replacing seals. One
grain of dirt between the seal
faces can cause failure.

13.Examine all O-rings for nicks

before using.

14.Be sure key is in place in notch

of shaft sleeve to prevent
sleeve from turning.

15.Use Locktite on socket head

locking screw in end of shaft.

16.Before refilling chamber with

oil, air test as described above.

17.Refill both chambers with oil

as described above.

18.Always check all leads with

high voltage or with Megger
for grounds before operating
the pump.

Pump
Maintenance

Содержание Hydromatic S4LRC-3450 RPM

Страница 1: ...ease make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system Submersible Sewage Pump Recessed Impeller S4LRC 3450 RPM Pump Installa...

Страница 2: ...r starter coil so that the starter is tripped if heat sensor opens The motor starter is equipped with 3 leg overload heaters so all normal overloads are protected by the starter IMPORTANT If Hydromati...

Страница 3: ...otor guarantee is void Hydromatic electrical equipment is installed in a weatherproof NEMA 3R enclosure WARNING Do not open swing cover until you have first disconnected the power HEAT SENSOR SEAL FAI...

Страница 4: ...p to piping A check valve must be installed on each pump A gate or plug valve in each pump discharge line is also recommended This valve should be installed on the discharge side of the check valve so...

Страница 5: ...iagram for wye delta see Addendum S4LRC 701 Heat Sensors and Seal Failure Connections Be sure that heat sensor wires are connected in series with the starter coil Connections are provided on the termi...

Страница 6: ...considerable lightning occurs it is recommended that a lightning arrestor be installed at the control panel Complete data on lightning arrestors and cost are available from the factory Lightning arres...

Страница 7: ...rough bearings can be reused and it is not necessary to completely dismantle pump to change bearings If bearings are damaged with dirt or heat they must be replaced See additional instructions on repl...

Страница 8: ...sleeve to remove Seal should come off with sleeve If sleeve is not free leave in place and push off when seal plate is removed 7 To remove seal plate take out socket head flat screws and using screws...

Страница 9: ...e is in the alternating relay Replace with new relay Pump runs but will not shut off 1 Pump may be air locked Turn pump off and let set for several minutes then restart 2 Lower float control may be hu...

Страница 10: ...0 8206 000 1 PLATE INSTRUCTION 1 41 266420210 STATOR 460 3 60 40 60 HP 1 266420211 STATOR 575 3 60 40 60 HP 1 Ref Part Part No No Description Qty 42 14870 011 5 ROTOR SHAFT 40 60 HP 1 43 178 005 1 SCR...

Страница 11: ...11 Wiring Diagrams...

Страница 12: ...isposition Any transportation charges involved in such disposition shall be for the Buyer s account The Buyer s exclusive and sole remedy on account or in respect of the furnishing of material that do...

Отзывы: