4. Set assembly on bench and 

remove connection box. When
box is lifted off, connection
wires to motor will be
exposed. These wires will
probably be burned, but each
wire is tagged with a metal
marker giving wire number.
Cut the wires.

If the leads to the connection
box are burned, a complete
new connection box with new
wire must be used. The wires
are potted in with sealing 
compound and a new unit must
be obtained from the factory.

5. The stator is held in the housing

with a bolted-in end ring and
an outside locking screw to
prevent stator from turning. 

6. After ring is removed, turn

housing upright and bump on
hardwood blocks. This should
jar the stator loose and allow it
to drop out.

7. Thoroughly clean housing

before replacing new stator.
Replace stator and make all
wire connections to connection
box before replacing housing
on pump. This is important as
leads must be tucked behind
the windings by using hands
up through rotor core.

IMPORTANT: Use only 
compression type insulated 
connectors on the wires.
DO NOT TAPE LEADS AS
OIL WILL DETERIORATE
THE TAPE AND CAUSE
DAMAGE TO STATOR AND
BEARINGS.

8. Drain oil from chamber. If 

oil is clean and no water is 
present, seals can be considered
satisfactory to reuse.

9. Check top bearing. If clean and

does not turn rough, bearings
can be reused and it is not 

necessary to completely 
dismantle pump to change
bearings. If bearings are 
damaged with dirt or heat, they
must be replaced. See additional 
instructions on replacing seals
and bearings. Remember to
reinstall the upper bearing 
load spring.

10.Before replacing stator housing,

be sure outside lock screw is in
place and that O-ring is used
under head of bolt. A leak here
can cause a motor failure. If a
new stator has been used, it
will be necessary to drill into
the stator lamination for a
holding socket for bolt (

29

64

dia.

drill, 

1

2

" deep, and 

1

2

-20 UNF,

3

8

deep into the stator). This 

holding spot is drilled through
the bolt hole when the stator 
is bolted in place with the 
end ring.

11.Replace stator housing onto

seal chamber and bolt in place. 

BE SURE SEAL FAILURE 
WIRE IS CONNECTED
BEFORE HOUSING IS
ASSEMBLED.

Be sure back-off screws have
been loosened so that parts 
can come metal to metal. Be
sure O-ring seal has been
replaced. If O-ring is nicked or
cut, replace with new ring.
This applies to all O-rings used
in assembly.

12.After all leads are reconnected

in the connection box, make a
high voltage ground test on
each wire. The only wire that
should show ground is the
green power lead and the
ground lead in the auxiliary
control cable.

13.For safety, complete pump

should be air checked under
water for leaks. If seals were
OK, refill seal chamber with
oil. Lay pump on side for this
oil filling with oil fill hole

Содержание Hydromatic S4LRC-3450 RPM

Страница 1: ...ease make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system Submersible Sewage Pump Recessed Impeller S4LRC 3450 RPM Pump Installa...

Страница 2: ...r starter coil so that the starter is tripped if heat sensor opens The motor starter is equipped with 3 leg overload heaters so all normal overloads are protected by the starter IMPORTANT If Hydromati...

Страница 3: ...otor guarantee is void Hydromatic electrical equipment is installed in a weatherproof NEMA 3R enclosure WARNING Do not open swing cover until you have first disconnected the power HEAT SENSOR SEAL FAI...

Страница 4: ...p to piping A check valve must be installed on each pump A gate or plug valve in each pump discharge line is also recommended This valve should be installed on the discharge side of the check valve so...

Страница 5: ...iagram for wye delta see Addendum S4LRC 701 Heat Sensors and Seal Failure Connections Be sure that heat sensor wires are connected in series with the starter coil Connections are provided on the termi...

Страница 6: ...considerable lightning occurs it is recommended that a lightning arrestor be installed at the control panel Complete data on lightning arrestors and cost are available from the factory Lightning arres...

Страница 7: ...rough bearings can be reused and it is not necessary to completely dismantle pump to change bearings If bearings are damaged with dirt or heat they must be replaced See additional instructions on repl...

Страница 8: ...sleeve to remove Seal should come off with sleeve If sleeve is not free leave in place and push off when seal plate is removed 7 To remove seal plate take out socket head flat screws and using screws...

Страница 9: ...e is in the alternating relay Replace with new relay Pump runs but will not shut off 1 Pump may be air locked Turn pump off and let set for several minutes then restart 2 Lower float control may be hu...

Страница 10: ...0 8206 000 1 PLATE INSTRUCTION 1 41 266420210 STATOR 460 3 60 40 60 HP 1 266420211 STATOR 575 3 60 40 60 HP 1 Ref Part Part No No Description Qty 42 14870 011 5 ROTOR SHAFT 40 60 HP 1 43 178 005 1 SCR...

Страница 11: ...11 Wiring Diagrams...

Страница 12: ...isposition Any transportation charges involved in such disposition shall be for the Buyer s account The Buyer s exclusive and sole remedy on account or in respect of the furnishing of material that do...

Отзывы: