INSTALLATION INSTRUCTIONS
60
Connecting the room thermostat (Option)
Connect the wires to the terminal board inside the instrument panel as follows:
TA terminals are 24volt DC. Accordingly only a non-power stealing device can be installed to the these
terminals.
a.
switch off the power supply at the main switch.
b.
remove the front case panel of the water heater.
c.
slacken the screws and remove plate A (see fig.1).
d.
remove jumper TA -TA from the terminal board B;
e.
connect the room thermostat/end switch wires;
When the wires have been connected, place plate
“
A
" back to position and then the front case panel.
Connecting the outside temperature sensor (Option)
Connect the wires to the terminal board inside the instrument panel as follows:
a.
switch off the power supply at the main switch.
b.
remove the front case panel of the water heater.
c.
slacken the screws and remove plate A (see fig.1).
d.
connect the outside temperature sensor on contacts marked as SE-SE on the terminal board B ;
e
. refer to the following page to set the reset curves.
When the wires have been connected, place plate
“
A
" back to position and then the front case panel.
Содержание PCI 18
Страница 8: ...GENERAL INFORMATION 5 ...
Страница 9: ...GENERALInformation 6 ING ...
Страница 10: ...GENERALInformation 7 ...
Страница 11: ...GENERALInformation 8 ...
Страница 25: ...INSTALLATION INSTRUCTIONS 22 3 6 Piping Diagram ...
Страница 33: ...INSTALLATION INSTRUCTIONS 29 Venting Pictures Illustrations ...
Страница 34: ...INSTALLATION INSTRUCTIONS 30 Included With Each Combination Water Heater Is A PAHVK Horizontal Kit ...
Страница 63: ...INSTALLATION INSTRUCTIONS 59 6 8 Wiring diagrams ...
Страница 69: ...65 6 13 Sequence of operations ...
Страница 70: ...66 Pensotti LLC 34 Coffin Ave Brewer ME 04412 P 207 942 3636 F 207 942 3737 www pensottiboiler com ...