INSTALLATION INSTRUCTIONS
62
6.10 Troubleshooting
ERROR
CODE
PROBLEM
POSSIBLE CAUSE
REMEDY
E01
NO FLAME
WITH NO IGNITION
a. NO GAS.
b. IGNITION ELECTRODE BROKEN OR GROUNDED.
c. GAS VALVE MALFUNCTION
d. MECHANICAL MINIMUM ADJUSTMENT (ON GAS VALVE) SET TOO
LOW OR SLOW IGNITION ADJUSTMENT SET TOO LOW .
e. GAS VALVE INLET PRESSURE TOO HIGH (FOR LPG W ATER HEATERS
ONLY );
WITH IGNITION
f. POWER SUPPLY LIVE AND NEUTRAL W IRES INVERTED.
g. IONIZATION ELECTRODE MALFUNCTION.
h. IONIZATION ELECTRODE CABLE DISCONNECTED.
WITH NO IGNITION
a. CHECK MAINS SUPPLY.
b. REPLACE PART.
c. REPLACE PART
d. REGULATE MECHANICAL MINIMUM OR SLOW
IGNITION.
e. CHECK THE MAXIMUM PRESSURE SETTING.
WITH IGNITION
f. CONNECT THE POW ER SUPPLY W IRES CORRECTLY.
g. REPLACE PART.
h. CONNECT THE IONIZATION ELECTRODE W IRE.
E02
SAFETY THERMOSTAT TRIPPED
(203°F) / AIR PRESSURE
SWITCH TRIPPED
i. THERMOSTAT MALFUNCTION OR OUT OF CALIBRATION.
j. THERMOSTAT CABLE DISCONNECTED.
AIR PRESSURE SWITCH
k. SWITCH OUT OF ORDER
l. INLET OR OUTLET FLUE GAS DUCTS OBSTRUCTED
m. SWITCH CABLE NOT STABLE
i. REPLACE PART.
j. CHECK THE W IRING ;
AIR PRESSURE SWITCH
k.
REPLACE PART
l.
CHECK FLUE GAS DUCTS
m. CHECK CABLE
E03
FLUESAFETY THERMOFUSE
n. THERMOFUSE BROKEN;
o. THERMOFUSE CABLE DICONNECTED;
p. THERMOFUSE LOCK OUT. (HIGH FLUETEMPERATURE)
n. REPLACE PART;
o. CHECK THE ELECTRICAL CONNECTION;
p. RESTART AND CHECK THE THERMOFUSE
H20
NO W ATER
IN THE
SYSTEM
q. INSUFFICIENT W ATER PRESSURE IN THE SYSTEM (STOPS AT 4.5 PSI
(0.3 BAR)).
r. W ATER PRESSURE SW ITCH CABLE DISCONNECTED.
s. W ATER PRESSURE SW ITCH MALFUNCTION.
q. FILL THE SYSTEM;
r. CHECK THE W IRING;
s. REPLACE PART;
E05
HEATING SENSOR
t. SENSOR MALFUNCTION OR OUT OF CALIBRATION (RESISTANCE
VALUE 10 kOhms AT 77 °F).
u. SENSOR CABLE DISCONNECTED OR W ET.
t. REPLACE PART;
u. CHECK THE ELECTRICAL CONNECTION;
E06
D.H.W SENSOR
v. SENSOR MALFUNCTION OR INCORRECT (RESISTANCE VALUE 10
kOhms AT 77 °F).
w. SENSOR CABLE DISCONNECTED OR W ET.
v. REPLACE PART;
w. CHECK THE ELECTRICAL CONNECTION ;
E16
FAN
x. BURNT FAN – BEFORE REPLACING FAN MOMENTLARL DISCONNECT
POWER TO THE APPLIANCE THEN RECONNECT POWER. IF ERROR CODE
CLEARS AND APPLAINCE OPERATES NORMAL DO NOT REPLACE THE
FAN.
x. REPLACE PART
E22
PARAMETER PROGRAMMING
REQUEST
y. LOSS OF MICROPROCESSOR MEMORY OR NEW PCB
y. REPROGRAM PARAMETERS;
E35
FLAME DETECTION
MALFUNCTION
z. IONIZATION ELECTRODE MALFUNCTION
aa. IONIZATION ELECTRODE CABLE MALFUNCTION
bb. PRINTED CIRCUIT BOARD MALFUNCTION
z. CLEAN IT OR REPLACE PART
aa. REPLACE PART
bb. REPLACE PART
E42
FAN PRINTED CIRCUIT BOARD
cc. FAN PRINTED CIRCUIT BOARD MALFUNCTION - BEFORE REPLACING
FAN CIRUCIT BOARD. MOMENTARLY DISCONNECT POWER TO THE
APPLIANCE THEN RECONNECT POWER. IF ERROR CODE CLEARS AND
APPLAINCE OPERATES NORMAL DO NOT REPLACE THE FAN CIRCUIT
BOARD.
cc. REPLACE PART
Содержание PCI 18
Страница 8: ...GENERAL INFORMATION 5 ...
Страница 9: ...GENERALInformation 6 ING ...
Страница 10: ...GENERALInformation 7 ...
Страница 11: ...GENERALInformation 8 ...
Страница 25: ...INSTALLATION INSTRUCTIONS 22 3 6 Piping Diagram ...
Страница 33: ...INSTALLATION INSTRUCTIONS 29 Venting Pictures Illustrations ...
Страница 34: ...INSTALLATION INSTRUCTIONS 30 Included With Each Combination Water Heater Is A PAHVK Horizontal Kit ...
Страница 63: ...INSTALLATION INSTRUCTIONS 59 6 8 Wiring diagrams ...
Страница 69: ...65 6 13 Sequence of operations ...
Страница 70: ...66 Pensotti LLC 34 Coffin Ave Brewer ME 04412 P 207 942 3636 F 207 942 3737 www pensottiboiler com ...