MAINTENANCE INSTRUCTIONS
38
5.2 Setting the parameters
To modify the pre-set values of the parameters reported in the previous table, open the parameter settings menu as
follows:
1. Place the On/Off switch in the OFF position.
2. Activate the On/Off switch while k
eeping buttons ‘+’
and “-“ pressed. Wait for “P 00” to appear on the display.
3. Release buttons ‘+’ and ‘-’.
4. Keep button ‘S’ pressed and use button ‘+’ and ‘-‘to
select the parameter to modify
.
5. Release button ‘S’,
then re-press and release it. The
display will indicate the value of the parameter to
modify.
Adjust the value of the parameter using the procedure
described in the following pages.
P 00
S
S
S
S
OFF
P 00
P 01
110V 60Hz
110V 60Hz
110V 60Hz
110V 60Hz