![PENSOTTI PCH 50B-H Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/pensotti/pch-50b-h/pch-50b-h_instruction-manual_1524147019.webp)
INSTALLATION INSTRUCTION
16
LCD DISPLAY ICONS’ KEY
1.
PARAMETER NUMBER INFORMATION
2. PARAMETERS PROGRAMMING MODE ON
3. SOLAR PCB CONNECTION INFORMATION / SOLAR
PANEL TEMPERATURE DISPLAY (d6)
4. SOLAR PUMP ON
5. STORAGE CYLINDER LOW LEVEL TEMPERATURE
VISUALIZATION (d7) / STORAGE CYLINDER HIGH
LEVEL TEMPERATURE VISUALIZATION (d8)
6. OUTDOOR TEMPERATURE SENSOR CONNECTED
7. TEMPERATURE / SET POINT / PARAMETER VALUE
INFORMATION
8. OPEN THERM COMPONENTS COMMUNICATION
CONNECTED (REMOTE CONTROL / ZONE
MANAGEMENT CONTROL BOX)
9. WATER LOW PRESSURE INFORMATION
10. (*) FLAME PRESENCE ON (3 POWER STEPS)
11. D.H.W. MODE ENABLED
12. RESETTABLE ERROR DISPLAY
13. OFF MODE
14. NOT RESETTABLE ERROR DISPLAY
15. HEATING MODE ENABLED
10 (*) - During the boiler operation the display can show 3
different power levels according to the flame modulation of
the boiler. (see flame icon/power % images)
2.8
INFO Menu display
P
ress the ‘
’ INFO Button to display the boiler data. Once pressed, the parameter number will appear
on the left side of the display and the associated parameter value will appear on the centre of the display.
Use ‘
’ and ‘
’ buttons of
Heating Temperature setting to scroll the list of available data.
P
ress the ‘
’ INFO button to exit the display mode.
The list of available display data is the following (D03
– D09 are not applicable):
Parameter
Icon
Description
d00
DHW sensor temperature
d01
Outdoor sensor temperature (only with sensor temperature
connected)
d02
Fan speed
d03
Low temperature circuit sensor (only with Zone PCB connected)
d04
Heating return sensor temperature (only with modulating pump
connected)
d05
Solar panel sensor temperature (only with Solar PCB connected)
d06
Solar storage cylinder temperature (low level) (only with Solar PCB
connected)
d07
Solar storage cylinder temperature (high level) (only with Solar PCB
connected)
d08
Solar panel sensor temperature 2 [ only with Solar PCB connected]
(SCS2)
d09
Extra Solar storage cylinder temperature [ only with Solar PCB
connected] (SBS3)
4
5
6
7
9
10
11
12
13
14
15
1
2
3
8
< 33%
>33%<66%
>66%<100%
Содержание PCH 50B-H
Страница 8: ...GENERALINFORMATION 5 ...
Страница 9: ...GENERALINFORMATION 6 ING ...
Страница 10: ...GENERALINFORMATION 7 ...
Страница 11: ...GENERALINFORMATION 8 ...
Страница 14: ...TECHNICALCHARACTERISTCS 11 2 2 Dimensions ...
Страница 35: ...INSTALLATION INSTRUCTION 32 Venting Pictures Illustrations ...
Страница 36: ...INSTALLATION INSTRUCTION 33 Part No PAHVK Horizontal Vent Kit ...
Страница 40: ...INSTALLATION INSTRUCTION 37 ...
Страница 41: ...INSTALLATION INSTRUCTION 38 Follow all venting manufacturers guidelines for low profile terminations ...
Страница 75: ...73 6 12 Sequence of operations ...
Страница 76: ...74 ...
Страница 77: ...75 ...
Страница 78: ...76 ...
Страница 79: ...77 ...