30
CONFIGURATION OF RS-232 PRINT CODES
These print code settings may be changed using either the local or remote display push-buttons,
or through RS-232 interface commands. When communication with the unit has been
established, the CFP (ConFigure Print code) command may be used as follows:
COMMAND FORMAT DESCRIPTION
CFP CFP 30 65 31 99 <ENT>
Send gross weight, CR\LF,
Send the net weight, End.
Up to 20 print codes can be entered. Refer to the Formatted Print Code List for additional print
codes.
\NOTE: Spaces must separate the settings and a "99" must be the final print code.
CONFIGURATION OF SLEEP MODE AND TIME/DATE
COMMAND FORMAT DESCRIPTION
CFL
CFL 5 <ENT>
Scale will enter sleep mode minutes after
last usage. A “0" will disable the sleep mode
and any number from .5 to 12 will determine
how many Minutes the scale will remain on.
CFN
CFN 0 0 1 0 <ENT>
Turns off weight per 1000 (0 = no, 1 = yes)
Disables two switch counting (0 = no, 1 =
yes) Percent display set to percent error (0 =
disable, 1 = error 2 = Accuracy) Turns off
auto sample to bulk (0 = no, 1 = yes)
CFT CFT 2 11 00 11 05 94 <ENT>
Scale will set the clock to 12 hour, currently
AM; the hour to 11:00, minutes to 0;
month to Nov; day to 5 and year to 1994.
NOTE:
Spaces must separate the settings and there must be 6 entries, followed by a carriage
return. The first number is the type of clock where: 1 = 24 hour clock mode, 2 = 12
hour clock mode (currently AM) and 3 = 12 hour clock mode (currently PM). The
second entry is the hour, the third is the minutes, fourth is the month, fifth is the day,
and the sixth is the year.