69
7 Installation instructions
7.2 Electrical connection
7.2.1 Common connection:
•
3 phase and 1 zero connection (3 1N, 400 V~/ 50 Hz):
º
The voltage between the phases and the zeros is
230 V~. The voltage between the two phases is
400 V~. Fit a connecting bridge between connecting
points 4-5. Phase 3 carries no load. The groups must
have fuses of at least 16 A (3x). The core diameter of
the connecting cable must be at least 2.5 mm
2
.
•
2 phase and 2 zero connection (2 2N, 230 V~ / 50 Hz):
º
The voltage between the phases and the zeros is 230 V~.
º
The group must have fuses of at least 16 A (2x). The
core diameter of the connecting cable must be at
least 2.5 mm
2
.
7.2.2 Special connections:
•
Single phase connection (1 1N, 230 V~ / 50 Hz):
º
The voltage between the phase and the zero is
230 V~. Fit a connecting bridge between connecting
points 1-2 and 4-5. The group must have a fuse of
at least 32 A. The core diameter of the connecting
should be at least 6 mm
2
.
7.2.3 Connection for hobs with 5 cooking zones:
•
3 phases with 1 zero connection (3 1N, 400 V~ / 50 Hz):
º
The voltage between the phases and the zero is
230 V~. The voltage between the phases is 400 V~.
Fit a connecting bridge between connecting points 4-5.
The groups must have fuses of at least 16 A (3x). The
core diameter of the connecting cable must be at least
2.5 mm
2
.