Hybrid Splitter/Merger - Not Always a Good Idea
The summing and splitting capabilities can be used simultaneously if you’re partially
using signals. However please be aware that using one instance of Directre to act as a
splitter and merger will induce latency on the signal path.
In the configuration above, the MAIN IN signal is split on the distribution bus to channels
1 through 4. Channels 1-4 are then routed to different signal paths via connections on
DIRECT OUTs 1-4. This isolates the MAIN IN signal from the summing bus.
Channels 5-8 are isolated from the distribution bus by connections on the DIRECT IN
sockets, this isolates channels 5-8 from the distribution bus and isolates the MAIN IN
from the MIX OUT sockets.
Again, it is not recommended that you route signals from DIRECT OUT 1-4 to paths that
connect back into DIRECT IN 5-8. This will induce latency on your signal path. Instead,
use two instances of Directre, one as a dedicated splitter and another as a dedicated
mixer.
v1.0.1 operation manual